Role of Pulse Pressure Amplification in Arterial Hypertension: Experts’ Opinion and Review of the Data
The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
A rterial hypertension is a major modifiable cardiovascular (CV) risk factor worldwide based on observational studies of brachial artery blood pressure (BP).In the latest guidelines of the European Society of Hypertension 1 for the management of arterial hypertension, aortic stiffness was introduced as an index of target organ damage.Three additional cardinal features of BP were also acknowledged: (1) systolic BP and pulse pressure (PP) may differ between the brachial artery and central arteries (ie, the aorta and its proximal branches), (2) the effects of antihypertensive drug treatment on brachial BP does not invariably reflect those seen on central BP, and (3) central BP is significantly related to CV events.Moreover, the guidelines acknowledged that noninvasive methods exist for the assessment of central hemodynamic parameters, such as central PP, and highlighted the need for large scale interventional studies that will further confirm the prognostic importance of central BP.Two years ago, coincident with the 6th International Workshop on the "Structure and Function of the Vascular System," in Paris, a consensus document on the role of central BP in arterial hypertension was published. 2It concluded that there is "mounting evidence suggesting that central BP and indices correlate more closely with intermediate markers of CV risk than brachial BP".It was also suggested that clinicians and researchers need to become familiarized with the disparity between peripheral and central BPs, ie, the phenomenon of pressure wave amplification.The present document is designed to address this need.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
(2003) · Journal of Hypertension · doi:10.1097/00004872-200306000-00001 · Cited by 3,027
Mancia, G., Rosei, E. A., Cífková, R., DeBacker, G., Erdine, S. E., Fagard, R., Farsang, C., Heagerty, A. M., Kawecka-Jaszcs, K., Kiowski, W., et al. (2003) · Lirias · doi:10.1097/01.hjh.0000059051.65882.32 · Cited by 2,601
Self-citationMcDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave Velocity
McEniery, C. M., Yasmin, Hall, I. R., Qasem, A., Wilkinson, I. B., & Cockcroft, J. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.037 · Cited by 1,359
Self-citationChen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Self-citationMonitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Palombo, C., Morizzo, C., Baluci, M., Lucini, D., Ricci, S., Biolo, G., Tortoli, P., & Kozakova, M. (2015) · BioMed Research International · doi:10.1155/2015/342565 · Cited by 750
Vlachopoulos, C., Xaplanteris, P., Aboyans, V., Brodmann, M., Cífková, R., Cosentino, F., De Carlo, M., Gallino, A., Landmesser, U., Laurent, S., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.05.007 · Cited by 716
Self-citationWang, K.-L., Cheng, H.-M., Sung, S.-H., Chuang, S.-Y., Li, C.-H., Spurgeon, H. A., Ting, C.-T., Najjar, S. S., Lakatta, E. G., Yin, F. C. P., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.139964 · Cited by 372
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Self-citationInteraction Between Hypertension and Arterial Stiffness: An Expert Reappraisal
Safar, M. E., Asmar, R., Benetos, A., Blacher, J., Boutouyrie, P., Lacolley, P., Laurent, S., London, G., Pannier, B., Protogerou, A., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11212 · Cited by 304
Self-citationArterial stiffness as a risk factor for clinical hypertension
Safar, M. E. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.155 · Cited by 299
Self-citationHerbert, A., Cruickshank, J. K., Laurent, S., & Boutouyrie, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu293 · Cited by 290
Self-citationAccuracy of Cuff-Measured Blood Pressure
Picone, D. S., Schultz, M. G., Otahal, P., Aakhus, S., Al-Jumaily, A. M., Black, J. A., Bos, W. J., Chambers, J. B., Chen, C.-H., Cheng, H.-M., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.05.064 · Cited by 277
Self-citationCharlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 256
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
“The accepted central BP reference standard is intra-arterial measurement by catheter, 4,53 but this method still requires careful handling by experienced operators to avoid measurement error.”
MethodSelf-citationBoutouyrie, P., Achouba, A., Trunet, P., & Laurent, S. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.148999 · Cited by 204
Self-citationWeber, T., Wassertheurer, S., Rammer, M., Haiden, A., Hametner, B., & Eber, B. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.194571 · Cited by 192
Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Wax, D. B., Lin, H.-M., & Leibowitz, A. B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182330286 · Cited by 178
Arterial stiffness in chronic kidney disease: causes and consequences
Chue, C. D., Townend, J. N., Steeds, R. P., & Ferro, C. J. (2010) · Heart · doi:10.1136/hrt.2009.184879 · Cited by 165
Cheng, H.-M., Chuang, S.-Y., Sung, S.-H., Yu, W.-C., Pearson, A., Lakatta, E. G., Pan, W.-H., & Chen, C.-H. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.06.029 · Cited by 148
Safar, M. E., Blacher, J., & Jankowski, P. (2011) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2011.04.039 · Cited by 141
Self-citationArmstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Kumar, N., Yang, M.-L., Sun, P., Hunker, K. L., Li, J., Jia, J., Fan, F., Wang, J., Ning, X., Gao, W., et al. (2024) · PLOS Genetics · doi:10.1371/journal.pgen.1011151 · Cited by 1
Metadata
- Authors
- Avolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H.
- Venue
- Hypertension
- Published
- 2009-08
- Volume
- 54
- Issue
- 2
- Pages
- 375-383
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2135326848
- Cited by
- 521
- References
- 78
- FWCI
- 20.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.