The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Nocturnal Hypertension: New Technology and Evidence
Open accessOverview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a single study showed that a two-night HBPM schedule with three automated measurements scheduled per night (total of six asleep BP readings) appears to be the minimum requirement for a reliable assessment of night-time HBPM, providing reasonable agreement with nocturnal ABPM and association with indices of preclinical organ damage [227].”
Citations
Cites
Empagliflozin, Cardiovascular Outcomes, and Mortality in Type 2 Diabetes
Zinman, B., Wanner, C., Lachin, J. M., Fitchett, D., Bluhmki, E., Hantel, S., Mattheus, M., Devins, T., Johansen, O. E., Woerle, H. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1504720 · Cited by 12,315
Canagliflozin and Cardiovascular and Renal Events in Type 2 Diabetes
Neal, B., Perkovic, V., Mahaffey, K. W., de Zeeuw, D., Fulcher, G., Erondu, N., Shaw, W., Law, G., Desai, M., & Matthews, D. R. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1611925 · Cited by 7,830
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Angiotensin-neprilysin inhibition versus enalapril in heart failure
McMurray, J. J. V., Packer, M., Desai, A. S., Gong, J., Lefkowitz, M. P., Rizkala, A. R., Rouleau, J. L., Shi, V. C., Solomon, S. D., Swedberg, K., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1409077 · Cited by 6,957
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Empagliflozin and Progression of Kidney Disease in Type 2 Diabetes
Wanner, C., Inzucchi, S. E., Lachin, J. M., Fitchett, D., von Eynatten, M., Mattheus, M., Johansen, O. E., Woerle, H. J., Broedl, U. C., & Zinman, B. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1515920 · Cited by 3,655
CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea
McEvoy, R. D., Antic, N. A., Heeley, E., Luo, Y., Ou, Q., Zhang, X., Mediano, O., Chen, R., Drager, L. F., Liu, Z., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1606599 · Cited by 2,101
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationKario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Self-citationOhkubo, T., Hozawa, A., Yamaguchi, J., Kikuya, M., Ohmori, K., Michimata, M., Matsubara, M., Hashimoto, J., Hoshi, H., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200211000-00017 · Cited by 1,053
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2014)
(2014) · Hypertension Research · doi:10.1038/hr.2014.20 · Cited by 1,049
European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021
Self-citationSega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Stroke Prognosis and Abnormal Nocturnal Blood Pressure Falls in Older Hypertensives
Kario, K., Pickering, T. G., Matsuo, T., Hoshide, S., Schwartz, J. E., & Shimada, K. (2001) · Hypertension · doi:10.1161/hy1001.092640 · Cited by 758
Self-citationTownsend, R. R., Mahfoud, F., Kandzari, D. E., Kario, K., Pocock, S., Weber, M. A., Ewen, S., Tsioufis, K., Tousoulis, D., Sharp, A. S. P., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32281-x · Cited by 752
Self-citationCall to Action on Use and Reimbursement for Home Blood Pressure Monitoring
Pickering, T. G., Miller, N. H., Ogedegbe, G. G., Krakoff, L. R., Artinian, N. T., & Goff, D. C. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 666
Nocturnal Fall of Blood Pressure and Silent Cerebrovascular Damage in Elderly Hypertensive Patients
Kario, K., Matsuo, T., Kobayashi, H., Imiya, M., Matsuo, M., & Shimada, K. (1996) · Hypertension · doi:10.1161/01.hyp.27.1.130 · Cited by 618
Self-citationRuilope, L. M., Dukát, A., Böhm, M., Lacourcière, Y., Gong, J., & Lefkowitz, M. P. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61966-8 · Cited by 598
Prognostic Effect of the Nocturnal Blood Pressure Fall in Hypertensive Patients
Salles, G. F., Reboldi, G., Fagard, R. H., Cardoso, C. R. L., Pierdomenico, S. D., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polónia, J. J., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06981 · Cited by 525
Self-citationUzu, T., Ishikawa, K., Fujii, T., Nakamura, S., Inenaga, T., & Kimura, G. (1997) · Circulation · doi:10.1161/01.cir.96.6.1859 · Cited by 410
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189011 · Cited by 294
Day-Night Dip and Early-Morning Surge in Blood Pressure in Hypertension
Verdecchia, P., Angeli, F., Mazzotta, G., Garofoli, M., Ramundo, E., Gentile, G., Ambrosio, G., & Reboldi, G. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.191858 · Cited by 287
Coleman, A. J., Steel, S., Freeman, P., de Greeff, A., & Shennan, A. H. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282cb57b6 · Cited by 260
Hoshide, S. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00567-3 · Cited by 239
Kario, K., Sun, N., Chiang, F., Supasyndh, O., Baek, S. H., Inubushi-Molessa, A., Zhang, Y., Gotou, H., Lefkowitz, M. P., & Zhang, J. Y. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02002 · Cited by 232
Self-citationWilliams, B., Cockcroft, J. R., Kario, K., Zappe, D., Brunel, P., Wang, Q., & Guo, W. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08556 · Cited by 226
Self-citationPalatini, P., Reboldi, G., Beilin, L. J., Casiglia, E., Eguchi, K., Imai, Y., Kario, K., Ohkubo, T., Pierdomenico, S. D., Schwartz, J. E., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03694 · Cited by 193
Self-citationObstructive sleep apnea syndrome and hypertension: ambulatory blood pressure
Kario, K. (2009) · Hypertension Research · doi:10.1038/hr.2009.56 · Cited by 185
Self-citationMorning Home Blood Pressure Is a Strong Predictor of Coronary Artery Disease
Kario, K., Saito, I., Kushiro, T., Teramukai, S., Tomono, Y., Okuda, Y., & Shimada, K. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.01.037 · Cited by 182
Self-citationIs Isolated Nocturnal Hypertension a Novel Clinical Entity?
Li, Y., Staessen, J. A., Lu, L., Li, L., Wang, G., & Wang, J. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.087767 · Cited by 169
Kario, K., Saito, I., Kushiro, T., Teramukai, S., Ishikawa, Y., Mori, Y., Kobayashi, F., & Shimada, K. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.04262 · Cited by 162
Self-citationWang, T., Tan, R., Lee, H., Ihm, S., Rhee, M., Tomlinson, B., Pal, P., Yang, F., Hirschhorn, E., PRESCOTT, M. F., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.08484 · Cited by 145
Kario, K. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.04.001 · Cited by 144
Self-citationKhan, S. U., Duran, C., Rahman, H., Lekkala, M. R., Saleem, M. A., & Kaluski, E. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx597 · Cited by 142
Kario, K., Chen, C.-H., Park, S., Park, C. G., Hoshide, S., Cheng, H., Huang, Q., & Wang, J.-G. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10238 · Cited by 131
Self-citationNighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Self-citationKario, K., Hoshide, S., Shimizu, M., Yano, Y., Eguchi, K., Ishikawa, J., Ishikawa, S., & Shimada, K. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283395267 · Cited by 122
Self-citationBavishi, C., Messerli, F. H., KADOSH, B. S., Ruilope, L. M., & Kario, K. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv142 · Cited by 108
Self-citationBrain Microbleeds Are Associated With Ambulatory Blood Pressure Levels in a Hypertensive Population
Henskens, L. H. G., van Oostenbrugge, R. J., Kroon, A. A., de Leeuw, P. W., & Lodder, J. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.100610 · Cited by 107
Kario, K., Tomitani, N., Kanegae, H., Yasui, N., Nishizawa, M., Fujiwara, T., Shigezumi, T., Nagai, R., & Harada, H. (2017) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2017.10.002 · Cited by 104
Self-citationDevice for the self-measurement of blood pressure that can monitor blood pressure during sleep
Chonan, K., Kikuya, M., Araki, T., Fujiwara, T., Suzuki, M., Michimata, M., Hashimoto, J., Ohkubo, T., Hozawa, A., Yamamoto, N., et al. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200108000-00008 · Cited by 95
Kollias, A., Ntineri, A., & Stergiou, G. S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001189 · Cited by 90
Kario, K., Bhatt, D. L., Kandzari, D. E., Brar, S., Flack, J. M., Gilbert, C., Oparil, S., Robbins, M., Townsend, R. R., & Bakris, G. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0035 · Cited by 84
Self-citationKidney and Circadian Blood Pressure Rhythm
Kimura, G. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.110213 · Cited by 77
Kario, K., Hoshide, S., Haimoto, H., Yamagiwa, K., Uchiba, K., Nagasaka, S., Yano, Y., Eguchi, K., Matsui, Y., Shimizu, M., et al. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12500 · Cited by 76
Self-citationKario, K. (2018) · Current Cardiology Reports · doi:10.1007/s11886-018-0944-4 · Cited by 73
Self-citationKario, K., Tomitani, N., Kanegae, H., Ishii, H., Uchiyama, K., Yamagiwa, K., Shiraiwa, T., Katsuya, T., Yoshida, T., Kanda, K., et al. (2017) · Circulation Journal · doi:10.1253/circj.cj-17-0109 · Cited by 71
Self-citationLi, Y., Wang, J., Gao, P., Guo, H.-F., Nawrot, T. S., Wang, G., Qian, Y., Staessen, J. A., & Zhu, D. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200506000-00003 · Cited by 69
LI, Y., WANG, J., GAO, P., GUO, H., Nawrot, T. S., WANG, G., Qian, Y., Staessen, J. A., & Zhu, D. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.03.098 · Cited by 67
Kario, K. (2018) · Circulation · doi:10.1161/circulationaha.117.032851 · Cited by 66
Self-citationKomori, T., Eguchi, K., Saito, T., Hoshide, S., & Kario, K. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0740 · Cited by 60
Self-citationKario, K. (2013) · Hypertension Research · doi:10.1038/hr.2013.19 · Cited by 57
Self-citationStergiou, G. S., Nasothimiou, E. G., Destounis, A., Poulidakis, E., Evagelou, I., & Tzamouranis, D. (2012) · American Journal of Hypertension · doi:10.1038/ajh.2012.82 · Cited by 55
Essential Manual of 24 Hour Blood Pressure Management: From Morning to Nocturnal Hypertension
Kario, K. (2015) · Cited by 54
Self-citationEffect of Catheter-Based Renal Denervation on Morning and Nocturnal Blood Pressure
Kario, K., Bhatt, D. L., Brar, S. K., Cohen, S. A., Fahy, M. P., & Bakris, G. L. (2015) · Hypertension · doi:10.1161/hypertensionaha.115.06260 · Cited by 49
Self-citationA New Technique for Detecting Sleep Apnea-Related "Midnight" Surge of Blood Pressure
Shirasaki, O., Yamashita, S., KAWARA, S.-I., Tagami, K., Ishikawa, J., Shimada, K., & Kario, K. (2006) · Hypertension Research · doi:10.1291/hypres.29.695 · Cited by 48
Self-citationYano, Y., Inokuchi, T., Hoshide, S., Kanemaru, Y., Shimada, K., & Kario, K. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2010.224 · Cited by 47
Self-citationIshikawa, J., Shimizu, M., Edison, E. S., Yano, Y., Hoshide, S., Eguchi, K., & Kario, K. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328365c8a8 · Cited by 45
Self-citationKario, K., Kuwabara, M., Hoshide, S., Nagai, M., & Shimpo, M. (2014) · Journal of Clinical Hypertension · doi:10.1111/jch.12327 · Cited by 40
Self-citationKuwabara, M., Hamasaki, H., Tomitani, N., Shiga, T., & Kario, K. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12878 · Cited by 38
Self-citationShirasaki, O., Kuwabara, M., Saito, M., Tagami, K., Washiya, S., & Kario, K. (2011) · Hypertension Research · doi:10.1038/hr.2011.52 · Cited by 36
Self-citationRiser Blood Pressure Pattern Is Associated With Mild Cognitive Impairment in Heart Failure Patients
Komori, T., Eguchi, K., Saito, T., Nishimura, Y., Hoshide, S., & Kario, K. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv086 · Cited by 34
Self-citationKollias, A., Andreadis, E., Agaliotis, G., Kolyvas, G. N., Achimastos, A., & Stergiou, G. S. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001562 · Cited by 34
Kario, K. (2010) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2010.06.005 · Cited by 33
Self-citationYano, Y., Ning, H., Muntner, P., Reis, J. P., Calhoun, D. A., Viera, A. J., Levine, D. A., Jacobs, D. R., Shimbo, D., Liu, K., et al. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv028 · Cited by 31
Validation of two automatic devices
Takahashi, H., Yoshika, M., & Yokoi, T. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000127 · Cited by 31
Yano, Y., Hoshide, S., Shimizu, M., Eguchi, K., Ishikawa, J., Ishikawa, S., Shimada, K., & Kario, K. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.229 · Cited by 30
Self-citationKuwabara, M., Tomitani, N., Shiga, T., & Kario, K. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13308 · Cited by 29
Self-citationYoshida, T., Kuwabara, M., Hoshide, S., & Kario, K. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.01.013 · Cited by 27
Self-citationKario, K., Ikemoto, T., Kuwabara, M., Ishiyama, H., Saito, K., & Hoshide, S. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12759 · Cited by 25
Self-citationKario, K., Weber, M. A., & Ferrannini, E. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13229 · Cited by 24
Self-citationKario, K., & Hamasaki, H. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12576 · Cited by 22
Self-citationFujiwara, T., Tomitani, N., Kanegae, H., & Kario, K. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13154 · Cited by 20
Self-citationFujiwara, T., Tomitani, N., Sato, K., Okura, A., Suzuki, N., & Kario, K. (2017) · Journal of Clinical Hypertension · doi:10.1111/jch.13087 · Cited by 19
Self-citationKario, K. (2011) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2011.03.006 · Cited by 18
Self-citationViera, A. J., & Hinderliter, A. L. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3281404a7e · Cited by 16
Shimizu, M., Ishikawa, J., Yano, Y., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., & Kario, K. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328351f80b · Cited by 15
Self-citationBenefits of strict blood-pressure lowering in hypertension
Kario, K. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.13 · Cited by 11
Self-citationSleep and Circadian Cardiovascular Medicine
Kario, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99606-6 · Cited by 4
Self-citationOBSOLETE: Sleep and Circadian Cardiovascular Medicine
Kario, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99606-5 · Cited by 1
Self-citation
Research works printed but not linked: 1
- Kario K. Essential Manual on Perfect 24-Hour Blood Pressure Management From Morning to Nocturnal Hypertension: Up-to-Date for Anticipation Medicine. Tokyo, Japan: Wiley-Blackwell; 2018:1–309.
Cited by
Sorted by citations
Böhm, M., Kario, K., Kandzari, D. E., Mahfoud, F., Weber, M. A., Schmieder, R. E., Tsioufis, K., Pocock, S., Konstantinidis, D., Choi, J. W., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30554-7 · Cited by 606
Self-citationKario, K., Hoshide, S., Mizuno, H., Kabutoya, T., Nishizawa, M., Yoshida, T., Abe, H., Katsuya, T., Fujita, Y., Okazaki, O., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.049730 · Cited by 324
Self-citationManagement of Hypertension in the Digital Era
Kario, K. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14742 · Cited by 247
Self-citationParati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Self-citationKario, K., Kanegae, H., Tomitani, N., Okawara, Y., Fujiwara, T., Yano, Y., Hoshide, S., & on behalf of the J-HOP Study Group (2019) · Hypertension · doi:10.1161/hypertensionaha.118.12740 · Cited by 167
Self-citation
Metadata
- Authors
- Kario, K.
- Affiliations
- Jichi Medical University (JP)
- Corresponding author
- Kario, Kazuomi
- ORCID
- Kario, Kazuomi
- Venue
- Hypertension
- Published
- 2018-06
- Volume
- 71
- Issue
- 6
- Pages
- 997-1009
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2802806041
- Cited by
- 298
- References
- 83
- Citations by year
- 2026: 49 · 2025: 45 · 2024: 27 · 2023: 40 · 2022: 28 · 2021: 32 · 2020: 46 · 2019: 26 · 2018: 5
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Hypertension (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (26293192, 17H06151)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- nocturnal hypertension, blood pressure, circadian rhythm, sleep
- MeSH terms
- Blood Pressure, Circadian Rhythm, Humans, Hypertension, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review