Small-Animal X-ray Dose from Micro-CT
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The use of micro-CT in small animals has increased in recent years. Although the radiation levels used for micro-CT are generally not lethal to the animal, they are high enough where changes in the immune response and other biological pathways may alter the experimental outcomes. Therefore, it is important to understand what the doses are for a specific imaging procedure. Monte Carlo simulation was used to evaluate the radiation dose to small animals (5–40 mm in diameter) as a result of X-ray exposure. Both monoenergetic (6–100 keV) and polyenergetic (15–100 kVp) X-ray sources were simulated under typical mouse imaging geometries. X-ray spectral measurements were performed on a mouse imaging X-ray system using a commercially available X-ray spectrometer, and spectra from high-energy systems were used as well. For a typical X-ray system with 1.0 mm of added Al at 40 kVp, the dose coefficients (dose to mouse per air kerma at isocenter) were 0.80, 0.63, 0.52, and 0.44 mGy/mGy for mouse diameters of 10, 20, 30, and 40 mm, respectively. A number of tables and figures are provided for dose estimation over a range of mouse imaging geometries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kV
Boone, J. M., & Seibert, J. A. (1997) · Medical Physics · doi:10.1118/1.597953 · Cited by 706 · cited 3×
“To provide dose coefficients for X-ray beams up to 100 kVp, a previous spectral model whose range was 40 to 140 kVp was used [12].”
MethodSelf-citationHigh resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Boone, J. M., Fewell, T. R., & Jennings, R. J. (1997) · Medical Physics · doi:10.1118/1.598100 · Cited by 452 · cited 1×
“A previously reported spectral modeling technique based on polynomial interpolation [11,12] was used to generate X-ray spectra which were subsequently used for dose computations.”
MethodSelf-citationFundamental image quality limits for microcomputed tomography in small animals
Ford, N. L., Thornton, M. M., & Holdsworth, D. W. (2003) · Medical Physics · doi:10.1118/1.1617353 · Cited by 210 · cited 1×
“Previous studies [1,6] have suggested that mouse imaging using micro-CT delivers between 100 and 300 mGy, about a factor of 10 larger than typical human CT examinations.”
BackgroundBoone, J. M., Shah, N., & Nelson, T. R. (2004) · Medical Physics · doi:10.1118/1.1636571 · Cited by 173 · cited 2×
“Previously reported comparisons [14] between SIERRA Monte Carlo dose measurements and physically measured results for the same CT geometry as that studied here but with larger cylinder diameters (10 to 20 cm) demonstrated excellent correlation (r = .”
MethodResultSelf-citationMitchel, R. E. J., Jackson, J. S., Morrison, D. P., & Carlisle, S. M. (2003) · Radiation Research · doi:10.1667/0033-7587(2003)159[0320:ldorit]2.0.co;2 · Cited by 163
Paulus, M. J., Gleason, S. S., Easterly, M. E., & Foltz, C. J. (2001) · PubMed · Cited by 146
Kapadia, R. D., Stroup, G. B., Badger, A. M., Koller, B. J., Levin, J. M., Coatney, R. W., Dodds, R. A., Liang, X., Lark, M. W., & Gowen, M. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-609 · Cited by 138
Simultaneous molecular and anatomical imaging of the mousein vivo
Goertzen, A. L., Meadors, A. K., Silverman, R. W., & Cherry, S. R. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/24/301 · Cited by 104 · cited 3×
“Most small-animal micro-CT systems make use of cone-beam geometry [1], and z-axis collimation lengths of 1, 4, 8, 12, and 16 cm were studied here.”
BackgroundSelf-citationMonte Carlo validation in diagnostic radiological imaging
Boone, J. M., Buonocore, M. H., & Cooper, V. N. (2000) · Medical Physics · doi:10.1118/1.599007 · Cited by 58
Self-citation
Cited by
Guidelines for the welfare and use of animals in cancer research
An ad hoc committee of the National Cancer Research Institute, Workman, P., Aboagye, E. O., Balkwill, F., Balmain, A., Bruder, G., Chaplin, D. J., Double, J. A., Everitt, J., Farningham, D. A. H., et al. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605642 · Cited by 1,442
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Boone, J. M. (2007) · Medical Physics · doi:10.1118/1.2713240 · Cited by 417
Self-citationPerovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Current Status of Developments and Applications of Micro-CT
Ritman, E. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124717 · Cited by 243
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
Boyd, S. K., Davison, P., Müller, R., & Gasser, J. A. (2006) · Bone · doi:10.1016/j.bone.2006.04.017 · Cited by 212
Cengiz, I. F., Oliveira, J. M., & Reis, R. L. (2018) · Biomaterials Research · doi:10.1186/s40824-018-0136-8 · Cited by 206
X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2055883 · Cited by 170
Cheong, S.-K., Jones, B. L., K Siddiqi, A., Liu, F., Manohar, N., & Cho, S. H. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/3/007 · Cited by 165
In vivo small animal imaging: Current status and future prospects
Kagadis, G. C., Loudos, G., Katsanos, K., Langer, S. G., & Nikiforidis, G. C. (2010) · Medical Physics · doi:10.1118/1.3515456 · Cited by 164
In vivo small animal micro-CT using nanoparticle contrast agents
Ashton, J. R., West, J. L., & Badea, C. T. (2015) · Frontiers in Pharmacology · doi:10.3389/fphar.2015.00256 · Cited by 162
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Microcomputed tomography colonography for polyp detection in an in vivo mouse tumor model
Pickhardt, P. J., Halberg, R. B., Taylor, A. J., Durkee, B. Y., Fine, J., Lee, F. T., & Weichert, J. P. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409915102 · Cited by 43
Quantitative increase in T regulatory cells enhances bone remodeling in osteogenesis imperfecta
Kang, I.-H., Baliga, U. K., Chatterjee, S., Chakraborty, P., Choi, S., Buchweitz, N., Li, H., Wu, Y., Yao, H., Mehrotra, S., et al. (2022) · iScience · doi:10.1016/j.isci.2022.104818 · Cited by 28
“Importantly, it has been established that radiation doses to mice are usually well below lethal doses (Boone et al., 2004).”
Background
Metadata
- Authors
- Boone, J. M., Velazquez, O., & Cherry, S. R.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-07-01
- Volume
- 3
- Issue
- 3
- Pages
- 149-158
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2121526802
- Cited by
- 201
- References
- 10
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›