Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundWhole-body optical imaging of green fluorescent protein-expressing tumors and metastases
Yang, M., Baranov, E., Jiang, P., Sun, F.-X., Li, X.-M., Li, L., Hasegawa, S., Bouvet, M., Al-Tuwaijri, M., Chishima, T., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.3.1206 · Cited by 514 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundBillinton, N., & Knight, A. W. (2001) · Analytical Biochemistry · doi:10.1006/abio.2000.5006 · Cited by 499 · cited 1×
“These chromophores have absorption bands centered from the ultraviolet to blue regions of the spectrum and emission bands throughout the visible spectrum [31,32].”
BackgroundIn vivo imaging of light-emitting probes
Rice, B. W., Cable, M. D., & Nelson, M. B. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1413210 · Cited by 493 · cited 1×
“Instrumentation An IVIS(1) Imaging System 100 Series with an XFO-6 fluorescent kit (Xenogen, Alameda, CA) was utilized for all measurements [29].”
MethodSelf-citationRapid and Quantitative Assessment of Cancer Treatment Response Using In Vivo Bioluminescence Imaging
Rehemtulla, A., Stegman, L. D., Cardozo, S. J., Gupta, S., Hall, D. E., Contag, C. H., & Ross, B. D. (2000) · Neoplasia · doi:10.1038/sj.neo.7900121 · Cited by 460 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundUse of Reporter Genes for Optical Measurements of Neoplastic Disease In Vivo
Contag, C. H., Jenkins, D., Contag, P. R., & Negrin, R. S. (2000) · Neoplasia · doi:10.1038/sj.neo.7900079 · Cited by 363 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundHawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Wu, J. C., Sundaresan, G., Iyer, M., & Gambhir, S. S. (2001) · Molecular Therapy · doi:10.1006/mthe.2001.0460 · Cited by 273 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundFrancis, K. P., Yu, J., Bellinger-Kawahara, C., Joh, D., Hawkinson, M. J., Xiao, G., Purchio, T. F., Caparon, M. G., Lipsitch, M., & Contag, P. R. (2001) · Infection and Immunity · doi:10.1128/iai.69.5.3350-3358.2001 · Cited by 249 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundImaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents
Reynolds, J. S., Troy, T. L., Mayer, R. H., Thompson, A. B., Waters, D. J., Cornell, K. K., Snyder, P. W., & Sevick-Muraca, E. M. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb01953.x · Cited by 204
Self-citationBouvet, M., Wang, J., Nardin, S. R., Nassirpour, R., Yang, M., Baranov, E., Jiang, P., Moossa, A. R., & Hoffman, R. M. (2002) · PubMed · Cited by 183
Wolfe, W. L. (1998) · SPIE eBooks · doi:10.1117/3.287476 · Cited by 150 · cited 1×
“The measured radiance from the reflector is then used to calculate E for each filter using the following method [30].”
MethodZhang, W., Feng, J. Q., Harris, S. E., Contag, P. R., Stevenson, D. K., & Contag, C. H. (2001) · Transgenic Research · doi:10.1023/a:1012042506002 · Cited by 121 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundNon-invasive image acquisition and advanced processing in optical bioimaging
Farkas, D. L., Du, C., Fisher, G. W., Lau, C., Niu, W., Wachman, E. S., & Levenson, R. M. (1998) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(98)00011-1 · Cited by 113 · cited 1×
“An extension of this approach is to use an array of fluorescent filters along with a spectral unmixing algorithm [33].”
MethodTumor Detection and Visualization Using Cyanine Fluorochrome-Labeled Antibodies
Ballou, B. T., Fisher, G. W., Hakala, T. R., & Farkas, D. L. (1997) · Biotechnology Progress · doi:10.1021/bp970088t · Cited by 77 · cited 1×
“Fluorescent dyes are far more numerous and have a much broader range of wavelengths, including the nearinfrared (NIR) range of 700–900 nm where tissue autofluorescence is lower [20].”
BackgroundFluorescence Lifetime Imaging of Experimental Tumors in Hematoporphyrin Derivative‐Sensitized Mice
Cubeddu, R., Canti, G. L., Pifferi, A., Taroni, P., & Valentini, G. (1997) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1997.tb08648.x · Cited by 72
Thompson, A. B., & Sevick-Muraca, E. M. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528205 · Cited by 64
TIME‐GATED FLUORESCENCE IMAGING FOR THE DIAGNOSIS OF TUMORS IN A MURINE MODEL
Cubeddu, R., Canti, G. L., Taroni, P., & Valentini, G. (1993) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1993.tb02322.x · Cited by 62
Burns, S. M., Joh, D., Francis, K. P., Shortliffe, L. M. D., Gruber, C. A., Contag, P. R., & Contag, C. H. (2001) · KARGER eBooks · doi:10.1159/000060392 · Cited by 33 · cited 1×
“Luciferase is a more responsive probe to rapidly changing environmental conditions such as infectious disease because these proteins mature rapidly following expression and are relatively short lived, whereas fluorescent proteins can take up to several hours to become functional after which they may reside in the cell…”
BackgroundInfluentialJacques, S. L. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.203427 · Cited by 8
Shorte, S. L., & Bolsover, S. R. (1999) · Elsevier eBooks · doi:10.1016/b978-012447836-7/50009-9 · Cited by 7
Cited by
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
“Subsequently, development of new fluorescent agents in the near-infrared spectrum will allow for identification of more deeply seated tumors, based on the stronger penetration properties of near-infrared dyes with an excitation wavelength >700 nm compared to FIT”
Characterization and application of single fluorescent nanodiamonds as cellular biomarkers
Fu, C.-C., Lee, H.-Y., Chen, K., Lim, T.-S., Wu, H.-Y., Lin, P.-K., Wei, P.-K., Tsao, P.-H., Chang, H.-C., & Fann, W. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605409104 · Cited by 860
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Self-illuminating quantum dot conjugates for in vivo imaging
So, M.-K., Xu, C., Loening, A. M., Gambhir, S. S., & Rao, J. (2006) · Nature Biotechnology · doi:10.1038/nbt1188 · Cited by 807
“However, imaging quantum dots in vivo is challenging owing to the requirement for external illumination, which produces strong background autofluorescence from ubiquitous endogenous chromophores such as collagens, porphyrins and flavin”
BackgroundWelsh, D. K., Yoo, S.-H., Liu, A. C., Takahashi, J. S., & Kay, S. A. (2004) · Current Biology · doi:10.1016/j.cub.2004.11.057 · Cited by 726
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.