Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
Background
Cited by
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
“Subsequently, development of new fluorescent agents in the near-infrared spectrum will allow for identification of more deeply seated tumors, based on the stronger penetration properties of near-infrared dyes with an excitation wavelength >700 nm compared to FIT”
Characterization and application of single fluorescent nanodiamonds as cellular biomarkers
Fu, C.-C., Lee, H.-Y., Chen, K., Lim, T.-S., Wu, H.-Y., Lin, P.-K., Wei, P.-K., Tsao, P.-H., Chang, H.-C., & Fann, W. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605409104 · Cited by 860
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Self-illuminating quantum dot conjugates for in vivo imaging
So, M.-K., Xu, C., Loening, A. M., Gambhir, S. S., & Rao, J. (2006) · Nature Biotechnology · doi:10.1038/nbt1188 · Cited by 807
“However, imaging quantum dots in vivo is challenging owing to the requirement for external illumination, which produces strong background autofluorescence from ubiquitous endogenous chromophores such as collagens, porphyrins and flavin”
BackgroundWelsh, D. K., Yoo, S.-H., Liu, A. C., Takahashi, J. S., & Kay, S. A. (2004) · Current Biology · doi:10.1016/j.cub.2004.11.057 · Cited by 726
Noninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604
In vivo imaging of hydrogen peroxide with chemiluminescent nanoparticles
Lee, D., Khaja, S., Velasquez-Castano, J. C., Dasari, M., Sun, C., Petros, J., Taylor, W. R., & Murthy, N. (2007) · Nature Materials · doi:10.1038/nmat1983 · Cited by 546
Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
“However, most bioluminescence probes currently in use emit the bulk of their optical signal at green wavelengths and are therefore attenuated very strongly if they are located deep in tissues (Troy et al 2004).”
BackgroundMethodInfluentialHarrell, M. I., Iritani, B. M., & Ruddell, A. (2007) · The American Journal of Pathology · doi:10.2353/ajpath.2007.060761 · Cited by 388
“Identical illumination settings (lamp voltage, filters) were used for all images, and fluorescence emission was normalized to fluorescent efficiency, where the value of each pixel in an efficiency image represents the fractional ratio of fluorescent emitted photons per incident excitation photon.(26) Mice were anesthe…”
BackgroundMethodInfluentialYu, M., Li, F., Chen, Z., Hu, H., Zhan, C., Yang, H., & Huang, C. (2009) · Analytical Chemistry · doi:10.1021/ac802072d · Cited by 378
Guidelines for minimal information on cellular senescence experimentation in vivo
Ogrodnik, M., Carlos Acosta, J., Adams, P. D., d’Adda di Fagagna, F., Baker, D. J., Bishop, C. L., Chandra, T., Collado, M., Gil, J., Gorgoulis, V., et al. (2024) · Cell · doi:10.1016/j.cell.2024.05.059 · Cited by 376
Lee, H., Yu, M. K., Park, S., Moon, S., Min, J. J., Jeong, Y. Y., Kang, H.-W., & Jon, S. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072210i · Cited by 330
Mansfield, J. R., Gossage, K. W., Hoyt, C. C., & Levenson, R. M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2032458 · Cited by 311
“Various solutions have been proposed for the reduction or elimination of autofluorescence.(9) These include using narrow bandpass emission filters in an effort to isolate the desired fluorescence signal, and the use of labels that can be excited at wavelengths in the near-infrared NIR that are much less likely to indu…”
BackgroundKaskova, Z. M., Tsarkova, A. S., & Yampolsky, I. V. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00296j · Cited by 306
Heyn, C., Ronald, J. A., Ramadan, S. S., Snir, J. A., Barry, A. M., MacKenzie, L. T., Mikulis, D. J., Palmieri, D., Bronder, J. L., Steeg, P. S., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21029 · Cited by 291
“optically opaque tissues, and are also seriously limited by spatial resolution, even in mice (28).”
BackgroundMultispectral imaging in biology and medicine: Slices of life
Levenson, R. M., & Mansfield, J. R. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20319 · Cited by 288
“orders of magnitude greater than with bioluminescence; the presence of autofluorescence is what generally limits achievable target-to-background ratios (21).”
BackgroundIn vivo magnetic resonance imaging of single cells in mouse brain with optical validation
Heyn, C., Ronald, J. A., MacKenzie, L. T., MacDonald, I. C., Chambers, A. F., Rutt, B. K., & Foster, P. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20747 · Cited by 290
“Similarly, in vivo whole body bioluminescence and fluorescence methods have a lower limit of cell detection in the range of hundreds to thousands of cells (24).”
BackgroundThe long-term stability and biocompatibility of fluorescent nanodiamond as an in vivo contrast agent
Vaijayanthimala, V., Cheng, P.-Y., Yeh, S.-H., Liu, K.-K., Hsiao, C.-H., Chao, J.-I., & Chang, H.-C. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.084 · Cited by 273
“The images were displayed after correction of tissue autofluorescence by subtracting the scaled background filter images (obtained at 430/35 nm excitation) from the primary filter images in order to achieve better image quality [44].”
BackgroundMethodBaumes, J. M., Gassensmith, J. J., Giblin, J., Lee, J.-J., White, A. G., Culligan, W. J., Leevy, W. M., Kuno, M., & Smith, B. D. (2010) · Nature Chemistry · doi:10.1038/nchem.871 · Cited by 273
“This signal contrast advantage for chemiluminescence increases with tissue penetration distanc”
BackgroundLázaro-Ibáñez, E., Faruqu, F. N., Saleh, A. F., Silva, A. M., Tzu-Wen Wang, J., Rak, J., Al-Jamal, K. T., & Dekker, N. (2021) · ACS Nano · doi:10.1021/acsnano.0c09873 · Cited by 273
Light transport in biological tissue based on the simplified spherical harmonics equations
Klose, A. D., & Larsen, E. W. (2006) · Journal of Computational Physics · doi:10.1016/j.jcp.2006.07.007 · Cited by 268
“Tomographic imaging of fluorescent and bioluminescent light sources inside tissue is used in fluorescence molecular tomography (FMT) and bioluminescence tomography (BLT) [5].”
MethodLighting up Tumors with Receptor-Specific Optical Molecular Probes
Achilefu, S. (2004) · Technology in Cancer Research & Treatment · doi:10.1177/153303460400300410 · Cited by 248
Review—Recent Progress in Portable Fluorescence Sensors
Shin, Y.-H., Teresa Gutierrez-Wing, M., & Choi, J.-W. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abd494 · Cited by 243
Agarwal, A., Mackey, M. A., El-Sayed, M. A., & Bellamkonda, R. V. (2011) · ACS Nano · doi:10.1021/nn201010q · Cited by 232
Molecular-Genetic Imaging Based on Reporter Gene Expression
Kang, J. H., & Chung, J.-K. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045955 · Cited by 228
“However, animal fluorescence imaging is hampered by low signal-to-background ratios and autofluorescence (19).”
BackgroundMultifocal Epithelial Tumors and Field Cancerization from Loss of Mesenchymal CSL Signaling
Hu, B., Castillo, E., Harewood, L., Ostano, P., Reymond, A., Dummer, R., Raffoul, W., Hoetzenecker, W., Hofbauer, G. F. L., & Dotto, G. P. (2012) · Cell · doi:10.1016/j.cell.2012.03.048 · Cited by 213
“Fluorescence diagnosis (FD) signal intensity was calculated as in Troy et al. (2004) (*p < 0.01).”
MethodInfluentialClose, D. M., Xu, T., Sayler, G. S., & Ripp, S. (2010) · Sensors · doi:10.3390/s110100180 · Cited by 204
Villa, I., Vedda, A., Cantarelli, I. X., Pedroni, M., Piccinelli, F., Bettinelli, M., Speghini, A., Quintanilla, M., Vetrone, F., Rocha, U., et al. (2015) · Nano Research · doi:10.1007/s12274-014-0549-1 · Cited by 203
Inorganic nanoparticles for optical bioimaging
Jaque, D., Richard, C., Viana, B., Soga, K., Liu, X., & García Solé, J. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000001 · Cited by 200
Darne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
“Autofluorescence from red excitation can be mitigated through chlorophyll-free animal chow (Troy et al 2004); however, autofluorescence still represents a significant noise floor that can prevent preclinical fluorescence molecular imaging studies.”
BackgroundThree-dimensional reconstruction of in vivo bioluminescent sources based on multispectral imaging
Kuo, C., Coquoz, O., Troy, T. L., Xu, H., & Rice, B. W. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717898 · Cited by 195
“The dynamic range is defined here to be the luminescent image maximum signal divided by an a priori threshold signal, below which is considered to be due to camera noise or animal background.(35) The signal above the threshold given by the dynamic range is converted to photon density on the surface vertices, as descri…”
BackgroundSelf-citationDeveloping MR reporter genes: promises and pitfalls
Gilad, A. A., Winnard, P. T., van Zijl, P. C. M., & Bulte, J. W. M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1134 · Cited by 189
“bioluminescent background (62), which is also mini-”
Bioluminescence imaging in living organisms
Welsh, D. K., & Kay, S. A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.006 · Cited by 185
“On the other hand, despite being dimmer, luciferases are actually more sensitive than fluorescent reporters, owing to the extremely low background levels of bioluminescence [4 ].”
BackgroundDeroose, C. M., De, A., Loening, A. M., Chow, P. L., Ray, P., Chatziioannou, A. F., & Gambhir, S. S. (2007) · Lirias · Cited by 187
Targeting Improves MSC Treatment of Inflammatory Bowel Disease
Ko, I. K., Kim, B.-G., Awadallah, A., Mikulan, J., Lin, P., Letterio, J. J., & Dennis, J. E. (2010) · Molecular Therapy · doi:10.1038/mt.2010.54 · Cited by 176
Diamond standard in diagnostics: nanodiamond biolabels make their mark
Barnard, A. S. (2009) · The Analyst · doi:10.1039/b908532g · Cited by 176
Advances in imaging mouse tumour models in vivo
Lyons, S. K. (2005) · The Journal of Pathology · doi:10.1002/path.1697 · Cited by 174
“A wide range of fluorescent materials are available that emit light in all portions of the visible spectrum [69]; however, many recent imaging studies have employed far-red and rear-infrared emitting fluorochromes (ie Cy5.”
BackgroundNon-Invasive Detection of a Small Number of Bioluminescent Cancer Cells In Vivo
Kim, J.-B., Urban, K., Cochran, E., Lee, S., Ang, A., Rice, B., Bata, A., Campbell, K., Coffee, R., Gorodinsky, A., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009364 · Cited by 156
“In contrast to fluorescence, BLI exhibits minimal background signals from the animal tissues[9].”
BackgroundSelf-citationIn vivo imaging using bioluminescence: a tool for probing graft-versus-host disease
Negrin, R. S., & Contag, C. H. (2006) · Nature Reviews Immunology · doi:10.1038/nri1879 · Cited by 172
Advances in functional X-ray imaging techniques and contrast agents
Chen, H., Rogalski, M. M., & Anker, J. N. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41858d · Cited by 168
Xia, Z., Xing, Y., So, M.-K., Koh, A. L., Sinclair, R., & Rao, J. (2008) · Analytical Chemistry · doi:10.1021/ac801562f · Cited by 168
Noninvasive biophotonic imaging for studies of infectious disease
Andreu, N., Zelmer, A., & Wiles, S. (2011) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2010.00252.x · Cited by 168
“However, as molecular microbiologists developing fluorescent/bioluminescent microorganisms, there are a number of factors that are somewhat within our control, namely: (1) FEMS Microbiol Rev 35 (2011) 360–394c 2010 Federation of European Microbiological Societies Published by Blackwell Publishing Ltd.”
BackgroundInfluentialKlerk, C. P. W., Overmeer, R. M., Niers, T. M. H., Versteeg, H. H., Richel, D. J., Buckle, T., Noorden, C. J. F. V., & van Tellingen, O. (2007) · BioTechniques · doi:10.2144/000112515 · Cited by 165
“BLI is performed in absolute darkness, thus avoiding the interference with background light and autofluorescence, making the measurement of small lesions more reliable 16,21,24 .”
InfluentialYe, M., Wang, X., Tang, J., Guo, Z., Shen, Y., Tian, H., & Zhu, W.-H. (2016) · Chemical Science · doi:10.1039/c6sc00970k · Cited by 154
In vivo bioluminescence imaging.
Satô, A., Klaunberg, B. A., & Tolwani, R. J. (2004) · PubMed · Cited by 157
Wehrman, T. S., von Degenfeld, G., Krutzik, P. O., Nolan, G. P., & Blau, H. M. (2006) · Nature Methods · doi:10.1038/nmeth868 · Cited by 151
Non‐Invasive in vivo Imaging in Small Animal Research
Koo, V., Hamilton, P. W., & Williamson, K. (2006) · Analytical Cellular Pathology · doi:10.1155/2006/245619 · Cited by 145
Recent advances in high-performance fluorescent and bioluminescent RNA imaging probes
Xia, Y., Zhang, R., Wang, Z., Tian, J., & Chen, X. S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00675b · Cited by 145
Molecular Imaging of Inflammation/Infection: Nuclear Medicine and Optical Imaging Agents and Methods
Signore, A., Mather, S. J., Piaggio, G., Malviya, G., & Dierckx, R. A. (2010) · Chemical Reviews · doi:10.1021/cr900351r · Cited by 143
Diet and Abdominal Autofluorescence Detected by in Vivo Fluorescence Imaging of Living Mice
Inoue, Y., Izawa, K., Kiryu, S., Tojo, A., & Ohtomo, K. (2008) · Molecular Imaging · doi:10.2310/7290.2008.0003 · Cited by 142
“For in vivo FLI in the far-red and NIR regions, feeding with alfalfa-free food is recommended to reduce autofluorescence owing to chlorophyll and its metabolites.(5,7) Imaging of the food pellets confirmed that the alfalfa-free diet exhibits weaker fluorescence in the far-red and NIR regions compared with the regular…”
BackgroundRecent Advances of Molecular Optical Probes in Imaging of β-Galactosidase
Zhang, J., Cheng, P., & Pu, K. (2019) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.9b00391 · Cited by 141
Luciferin Derivatives for Enhanced in Vitro and in Vivo Bioluminescence Assays
Shinde, R., Perkins, J., & Contag, C. H. (2006) · Biochemistry · doi:10.1021/bi060475o · Cited by 134
Cerenkov luminescence imaging: physics principles and potential applications in biomedical sciences
Ciarrocchi, E., & Belcari, N. (2017) · EJNMMI Physics · doi:10.1186/s40658-017-0181-8 · Cited by 133
“Even if there is no spurious emission due to an external excitation source as in fluorescence imaging, background autoluminescence from the bulk of the animal may limit the ability to detect bioluminescent probes [72].”
BackgroundYang, Z., Zheng, S., Harrison, W. J., Harder, J., Wen, X., Gelovani, J. G., Qiao, A., & Li, C. (2007) · Biomacromolecules · doi:10.1021/bm7005399 · Cited by 130
Real-Time Bioluminescence Imaging of Glycans on Live Cells
Cohen, A. S., Goun, E. A., Rush, J. S., & Bertozzi, C. R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja101766r · Cited by 120
Ray, P., Tsien, R. Y., & Gambhir, S. S. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-2402 · Cited by 120
“Fluorescence imaging in vivo has generally been limited by the autofluorescence of tissues, which reduces the sensitivity of detection and accuracy of quantization of the labeled target (28).”
BackgroundInjectable laminin-functionalized hydrogel for nucleus pulposus regeneration
Francisco, A. T., Mancino, R. J., Bowles, R. D., Brunger, J. M., Tainter, D. M., Chen, Y.-T., Richardson, W. J., Guilak, F., & Setton, L. A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.06.038 · Cited by 119
“Photon emission at the tissue surface depends on the number of delivered cells, the photon flux per cell (luciferin expression levels and luciferin availability), and the signal attenuation by the tissue [60].”
BackgroundDopp, B. J. L., Tamiev, D., & Reuel, N. F. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.12.006 · Cited by 115
Molecular Imaging of Apoptosis: From Micro to Macro
Zeng, W., Wang, X., Xu, P., Liu, G., Eden, H. S., & Chen, X. S. (2015) · Theranostics · doi:10.7150/thno.11548 · Cited by 111
Strategies to Overcome Autofluorescence in Nanoprobe‐Driven In Vivo Fluorescence Imaging
del Rosal, B., & Benayas, A. (2018) · Small Methods · doi:10.1002/smtd.201800075 · Cited by 110
Non‐invasive molecular imaging for preclinical cancer therapeutic development
O’Farrell, A. C., Shnyder, S. D., Marston, G., Coletta, P. L., & Gill, J. H. (2013) · British Journal of Pharmacology · doi:10.1111/bph.12155 · Cited by 109
Engineered Multifunctional Nanocarriers for Cancer Diagnosis and Therapeutics
Shi, D., Bedford, N. M., & Cho, H. (2011) · Small · doi:10.1002/smll.201100436 · Cited by 109
Dragulescu‐Andrasi, A., Liang, G., & Rao, J. (2009) · Bioconjugate Chemistry · doi:10.1021/bc9002508 · Cited by 107
Fluorescent protein tomography scanner for small animal imaging
Zacharakis, G., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843254 · Cited by 104
“5(b) shows the grayscale raw image recorded by the CCD camera and illustrates that 1) the tube is visible in fluorescent transillumination mode, 2) confined photon diffusion is experienced in the visible compared to NIR since the recorded pattern is quite narrow, resembling the tube geometry, and 3) the measurement is…”
Label-Free Luminescent Mesoporous Silica Nanoparticles for Imaging and Drug Delivery
Chen, H., Zhen, Z., Tang, W., Todd, T., Chuang, Y., Wang, L., Pan, Z., & Xie, J. (2013) · Theranostics · doi:10.7150/thno.6668 · Cited by 101
“These signals were due to digested food, not the particles [31, 41, 42].”
BackgroundImage analysis methods for diffuse optical tomography
Pogue, B. W., Davis, S. C., Song, X., Brooksby, B. A., Dehghani, H., & Paulsen, K. D. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2209908 · Cited by 99
“One comprehensive paper on this issue by Troy et al. 77 showed effective point spread functions as measured in phantoms and in vivo , using small numbers of cells to assess the minimum detectable number of photons and cells.”
BackgroundIn-vivo fluorescence imaging with a multivariate curve resolution spectral unmixing technique
Xu, H., & Rice, B. W. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3258838 · Cited by 98
“To provide a consistent measurement against different imaging conditions so that signals are traceable over time and on different instruments, the imaging system is absolutely calibrated for spectral radiance traceable to the National Institute of Standards and Technology NIST .(7,21) This calibration provides the con…”
BackgroundMethodSelf-citationLanthanide-doped near-infrared II luminescent nanoprobes for bioapplications
Yu, S., Tu, D., Lian, W., Xu, J., & Chen, X. (2019) · Science China Materials · doi:10.1007/s40843-019-9414-4 · Cited by 97
Bioluminescence imaging in live cells and animals
Tung, J. K., Berglund, K., Gutekunst, C., Hochgeschwender, U., & Gross, R. E. (2016) · Neurophotonics · doi:10.1117/1.nph.3.2.025001 · Cited by 95
“This is due to the fact that background luminescence is negligible compared to the signal produced from the luciferase reaction.(28) Bioluminescent signals can therefore be much more sensitive than fluorescent signals, which generally have to compete with background auto-fluorescence.”
Drake, J. M., Gabriel, C. L., & Henry, M. D. (2005) · Clinical & Experimental Metastasis · doi:10.1007/s10585-006-9011-4 · Cited by 94
“magnitude less sensitive than BLI [28].”
Winnard, P. T., Kluth, J. B., & Raman, V. (2006) · Neoplasia · doi:10.1593/neo.06304 · Cited by 94
“within the wavelength region where animal tissue has high absorption/autofluorescence [7,11,12,31].”
BackgroundMethodHui, Y. Y., Su, L., Chen, O. J., Chen, Y., Liu, T., & Chang, H. (2014) · Scientific Reports · doi:10.1038/srep05574 · Cited by 93
In Vivo Pathology: Seeing with Molecular Specificity and Cellular Resolution in the Living Body
Contag, C. H. (2007) · Annual Review of Pathology Mechanisms of Disease · doi:10.1146/annurev.pathol.2.010506.091930 · Cited by 89
In vivo imaging of early stage apoptosis by measuring real-time caspase-3/7 activation
Scabini, M., Stellari, F., Cappella, P., Rizzitano, S., Texidó, G., & Pesenti, E. A. (2010) · APOPTOSIS · doi:10.1007/s10495-010-0553-1 · Cited by 87
“However, strategies that rely on fluorescent signals have drawbacks when used in vivo because of the high scattering and the high auto fluorescence rates of visible and near-infrared light in tissues and blood, thus resulting in lower signal to noise ratio [13, 14].”
BackgroundBroad host range fluorescence and bioluminescence expression vectors for Gram-negative bacteria
Karsi, A., & Lawrence, M. L. (2007) · Plasmid · doi:10.1016/j.plasmid.2006.11.002 · Cited by 86
Shan, Y., Abel, J. H., Li, Y., Izumo, M., Cox, K. H., Jeong, B., Yoo, S. H., Olson, D. P., Doyle, F. J., & Takahashi, J. S. (2020) · Neuron · doi:10.1016/j.neuron.2020.07.012 · Cited by 85
“, 1995), in vivo bioluminescence imaging has long been used to observe circadian rhythms in real time, due to its extremely low background and high signal-to-noise ratio (Troy et al., 2004; Yamazaki and Takahashi, 2005).”
BackgroundNoninvasive Optical Imaging of Ovarian Metastases Using Cy5-labeled RAFT-c(-RGDfK-) 4
Jin, Z.-H., Josserand, V., Razkin, J., Garanger, É., Boturyn, D., Favrot, M., Dumy, P., & Coll, J. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00022 · Cited by 85
“Vol. 5, No. 3, July 2006 cells, stably expressing luciferase, was monitored using BLI.”
BackgroundInfluentialMultiplexing with Multispectral Imaging: From Mice to Microscopy
Levenson, R. M., Lynch, D. T., Kobayashi, H., Backer, J. M., & Backer, M. V. (2008) · ILAR Journal · doi:10.1093/ilar.49.1.78 · Cited by 82
“The contribution from chlorophyll-related compounds can be reduced by switching the test subjects to one of a variety of specially formulated diets (Troy et al. 2004).”
BackgroundBiodistribution of RNA Vaccines and of Their Products: Evidence from Human and Animal Studies
Pateev, I., Seregina, K., Ivanov, R. A., & Reshetnikov, V. V. (2023) · Biomedicines · doi:10.3390/biomedicines12010059 · Cited by 81
“Firstly, the bioluminescence intensity in vivo is dependent on the photon flux per cell, the number of cells, and the migration of photons through tissue [23].”
BackgroundNoninvasive Molecular Imaging Using Reporter Genes
Brader, P., Serganova, I. S., & Blasberg, R. G. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099788 · Cited by 79
“Bioluminescence imaging is more sensitive for small-animal imaging than is fluorescence imaging, because of high signal-to-background ratios and absence of autoluminescence (12).”
BackgroundIn Vivo Cellular Imaging for Translational Medical Research
Arbab, A. S., Janic, B., Haller, J., Pawelczyk, E., Liu, W. X., & Frank, J. A. (2009) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340509787354697 · Cited by 78
“Enhanced red-shifted versions of fluorescent proteins such as DsRed, proved capable of giving several orders of magnitude higher signal intensity in vivo, as compared to bioluminescence, however the large background autofluorescence severely reduces signal-to-noise ratio [63].”
BackgroundMethodCellular Bioluminescence Imaging
Welsh, D. K., & Noguchi, T. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top070607 · Cited by 78
“ohbai 580 nm Toyobo (Osaka, Japan) Viviani et al. (2001) SLR Railroad worm Phrixithrix hirtus 630 nm Toyobo (Osaka, Japan) Viviani et al.”
BackgroundRadionuclide‐Activated Nanomaterials and Their Biomedical Applications
Ferreira, C. A., Ni, D., Rosenkrans, Z. T., & Cai, W. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201900594 · Cited by 78
Deroose, C. M., Reumers, V., Gijsbers, R., Bormans, G. M., Debyser, Z., Mortelmans, L. A., & Baekelandt, V. (2006) · Molecular Therapy · doi:10.1016/j.ymthe.2006.05.007 · Cited by 70
“Although the background signal derived from the snout is higher than that in oncology or cardiology studies, this is still many times lower than the typical fluorescent background encountered in fluorescent-based imaging strategies [31].”
BackgroundImproved QD-BRET conjugates for detection and imaging
Xing, Y., So, M., Koh, A. L., Sinclair, R., & Rao, J. (2008) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2008.04.159 · Cited by 70
“However, in vivo imaging using quantum dots still faces challenges such as interferences from tissue autofluorescence [4] and paucity of light available at non-superficial tissue sites [5].”
Non-invasive visualization of CNS inflammation with nuclear and optical imaging
Wunder, A. P., Klohs, J., & Dirnagl, U. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.10.005 · Cited by 70
A hyperspectral fluorescence system for 3Din vivooptical imaging
Zavattini, G., Vecchi, S., Mitchell, G. S., Weisser, U., Leahy, R. M., Pichler, B. J., Smith, D., & Cherry, S. R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/8/005 · Cited by 69
“…path lengths allow sufficient photon flux to reach the surface of the animal (especially in the NIR part of the spectrum ∼650–950 nm) enabling fluorescence and bioluminescence emissions to be detected with good signal-to-noise ratios (Troy et al 2004) and using relatively low-cost instrumentation.”
BackgroundMolecular Imaging of Metastatic Potential
Winnard, P. T., Pathak, A. P., Dhara, S., Cho, S. Y., Raman, V., & Pomper, M. G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045948 · Cited by 68
“Firefly-based BLI penetrates mammalian tissue to a greater depth than GFP fluorescence (159,160).”
BackgroundResultCellular Magnetic Resonance Imaging: In Vivo Imaging of Melanoma Cells in Lymph Nodes of Mice
Foster, P. J., Dunn, E. A., Karl, K. E., Snir, J. A., Nycz, C. M., Harvey, A., & Pettis, R. J. (2008) · Neoplasia · doi:10.1593/neo.07937 · Cited by 67
“Optical techniques, such as bioluminescence imaging, while sensitive to small numbers of cells (detection limits of 1000 cells), are limited by the penetration of light through optically opaque tissues and are also seriously limited by spatial resolution, even in mice [36].”
BackgroundAlexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/8/006 · Cited by 67
“Mouse tissues are known to have a spatially heterogeneous autoluminescence background (Troy et al 2004), which was not modelled here.”
BackgroundIn Vivo Deep Tissue Fluorescence and Magnetic Imaging Employing Hybrid Nanostructures
Ortgies, D. H., de la Cueva, L., del Rosal, B., Sanz-Rodríguez, F., Fernández, N., de la Cruz, M. D. C. I., Salas, G., Cabrera, D. M., Terán, F. J., Jaque, D., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b10617 · Cited by 63
Berlec, A., Završnik, J., Butinar, M., Turk, B., & Štrukelj, B. (2015) · Microbial Cell Factories · doi:10.1186/s12934-015-0376-4 · Cited by 61
“Alfalfa-free Teklad global rodent diet 2016 was used to minimize background intestinal fluorescence [34] at least 4 days before the start of experiments.”
MethodSaban, R., Saban, M. R., Maier, J., Fowler, B., Tengowski, M., Davis, C. A., Wu, X.-R., Culkin, D. J., Hauser, P., Backer, J., et al. (2008) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.90344.2008 · Cited by 56
“Female mice were fed a low-chlorophyll diet for 2 wk to reduce autofluorescence in the intestinal region (54), and the abdominal hair was removed.”
MethodClose, D. M., Hahn, R. E., Patterson, S. S., Ripp, S. A., Sayler, G. S., & Baek, S. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3564910 · Cited by 59
Terziyska, N., Alves, C. C., Groiß, V., Schneider, K., Farkasova, K., Ogris, M., Wagner, E., Ehrhardt, H., Brentjens, R. J., Stadt, U. Z., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052798 · Cited by 59
“Even though leukemic cells used in our studies also expressed GFP, GFP proved non-suitable for in vivo imaging due to the known high tissue autofluorescence signals emitted at the same wave length [28].”
Ramanujan, V. K., Zhang, J.-H., Biener, E., & Herman, B. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2098753 · Cited by 59
“carried out a quantitative evaluation of the sensitivity of detection of fluorescent reporters in animal models and found that the signal-to-background ratio in fluorescence imaging is typically 8, which is lower than that in cells by a few orders of magnitude.(34) A key to successful disease diagnosis is to detect th…”
BackgroundCell Tracking 2007: A Proliferation of Probes and Applications
Wallace, P. K., & Muirhead, K. A. (2007) · Immunological Investigations · doi:10.1080/08820130701812584 · Cited by 59
Imaging Enzymes at Work: Metabolic Mapping by Enzyme Histochemistry
Noorden, C. J. F. V. (2010) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.2010.955518 · Cited by 60
Akers, W. J., Lesage, F., Holten, D., & Achilefu, S. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00020 · Cited by 59
“exogenous contrast agents used in this study, background fluorescence intensity and lifetimes can be readily eliminated without subjecting the animal to special diets, such as chlorophyll-free foods.(21) At the much lower excitation laser power (50 mW) used for the treated mice, the signal for the untreated mice was p…”
BackgroundDynamic Monitoring of Oncolytic Adenovirus In Vivo by Genetic Capsid Labeling
Le, L. P., Le, H. N., Dmitriev, I. P., Davydova, J. G., Gavrikova, T. A., Yamamoto, S., Curiel, D. T., & Yamamoto, M. (2006) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djj022 · Cited by 59
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.