The influence of micro-topography on cellular response and the implications for silicone implants
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Tissue attachment to substratum surfaces is of central importance to the in vivo performance of prosthetic implant materials. It is not yet understood why connective tissue does not attach to the surface of silicone or any other polymeric material. Recently the authors have conclusively demonstrated that micro-range surface roughness modifies cellular responses in cell culture and modifies biocompatibility and tissue attachment in vivo significantly. In order to better understand the basic interactions between living cells or tissues on one hand and man-made substratum surfaces on the other hand, the germane literature is reviewed here. Cells adhere to substratum surfaces mainly through focal adhesions which are a complex of intracellular transmembrane and extracellular proteins. Adhesion is facilitated and modified by proteins adsorbed to the substratum surface. Protein adsorption in turn is modified by the underlying substratum surface properties including surface chemistry, charge, and free energy. When silicone and other polymeric implants having well-defined surface topographic features including pores, pillars, or grooves were implanted, the tissue response to these implants was strongly influenced by the dimensions of these features as well as by other geometric details. Highest biocompatibility along with tissue attachment was seen when topographic features had dimensions of 1-3 microns and a uniform distribution. Cell culture studies revealed that topographic features affect cellular alignment, direction of proliferation, cellular attachment, growth rate, metabolism, and cytoskeletal arrangement. Since discontinuities or curvatures associated with topographic features may represent local changes in surface free energy, it is hypothesized that these discontinuities trigger changes in protein adsorption, protein configuration, and cellular response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Wilkinson, D. W. (1987) · doi:10.1242/dev.99.3.439 · Cited by 418
The role of integrins in the maintenance of endothelial monolayer integrity.
Lampugnani, M. G., Resnati, M., Dejana, E., & Marchisio, P. C. (1991) · The Journal of cell biology · doi:10.1083/jcb.112.3.479 · Cited by 292
Opas, M. (1989) · Developmental Biology · doi:10.1016/s0012-1606(89)80001-6 · Cited by 114
Cited by
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450
Epithelial contact guidance on well-defined micro- and nanostructured substrates
Teixeira, A. I., Abrams, G. A., Bertics, P. J., Murphy, C. J., & Nealey, P. F. (2003) · Journal of Cell Science · doi:10.1242/jcs.00383 · Cited by 978
Surface modification and property analysis of biomedical polymers used for tissue engineering
Ma, Z., Mao, Z., & Gao, C. (2007) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2007.06.019 · Cited by 590
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Three-dimensional electrospun ECM-based hybrid scaffolds for cardiovascular tissue engineering
Heydarkhan-Hagvall, S., Schenke-Layland, K., Dhanasopon, A. P., Rofail, F., Smith, H., Wu, B. M., Shemin, R., Beygui, R. E., & MacLellan, W. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.034 · Cited by 445
Sussman, E. M., Halpin, M. C., Muster, J., Moon, R. T., & Ratner, B. D. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0933-0 · Cited by 416
Improved Cellular Infiltration in Electrospun Fiber via Engineered Porosity
Nam, J., Huang, Y., Agarwal, S., & Lannutti, J. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0306 · Cited by 414
Designing of PLA scaffolds for bone tissue replacement fabricated by ordinary commercial 3D printer
Gregor, A., Filová, E., Novák, M., Kronek, J., Chlup, H., Buzgo, M., Blahnová, V., Lukášová, V., Bartoš, M., Nečas, A., et al. (2017) · Journal of Biological Engineering · doi:10.1186/s13036-017-0074-3 · Cited by 406
Nanoscale features influence epithelial cell morphology and cytokine production
Andersson, A.-S., Bäckhed, F., von Euler, A., Richter-Dahlfors, A., Sutherland, D., & Kasemo, B. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00208-4 · Cited by 347
Bone tissue regeneration: biology, strategies and interface studies
Ansari, M. (2019) · Progress in Biomaterials · doi:10.1007/s40204-019-00125-z · Cited by 340
Schwartz, Z., Lohmann, C. H., Oefinger, J., Bonewald, L. F., Dean, D. D., & Boyan, B. D. (1999) · Advances in Dental Research · doi:10.1177/08959374990130011301 · Cited by 308
Biomaterial topography alters healing in vivo and monocyte/macrophage activation in vitro
Bota, P. C. S., Collie, A. M. B., Puolakkainen, P., Vernon, R. B., Sage, E. H., Ratner, B. D., & Stayton, P. S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32893 · Cited by 186
Biological Performance of Materials
Barbucci, R., Lamponi, S., & Magnani, A. (2000) · Chemistry at the Beginning of the Third Millennium · doi:10.1007/978-3-662-04154-3_8 · Cited by 184
He, J., Zhou, W., Zhou, X., Zhong, X., Zhang, X., Wan, P., Zhu, B., & Chen, W. (2008) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-008-3505-3 · Cited by 182
Surface patterning: Tool to modulate stem cell differentiation in an adipose system
Chaubey, A., Ross, K. J., Leadbetter, R. M., & Burg, K. J. L. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30846 · Cited by 50
Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., & Bale, S. D. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10525 · Cited by 35
Spiller, D., Mirtelli, C., Losi, P., Briganti, E., Sbrana, S., Counoupas, C., Kull, S., Tonlorenzi, S., & Soldani, G. (2009) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-009-3823-0 · Cited by 15
“The adhesion of inflammatory cells, especially monocytes/macrophages, is dictated by the types of adsorbed proteins that covered the material surface immediately after implant; this especially depends on material wettability [23], surface texture and roughness [ 24 ], and chemistry [25, 26].”
Background
Metadata
- Authors
- Von Recum, A. F., & Van Kooten, T. G.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 7
- Issue
- 2
- Pages
- 181-198
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1987659834
- Cited by
- 251
- References
- 4
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.