Inner Retinal Mechanisms Engaged by Retinal Electrical Stimulation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: Retinal prosthetic devices are being developed to bypass degenerated retinal photoreceptors by directly activating retinal neurons with electrical stimulation. However, little is known about retinal activity during such stimulation. METHODS: Whole cell patch-clamp recordings were obtained from ganglion and bipolar cells in the salamander retinal slice preparation. A stimulating electrode was positioned at the vitreal surface of the slice. RESULTS: Brief pulses of cathodic current evoked transient inward currents in ganglion cells arising from action potentials. Longer pulses (>5 milliseconds) also evoked sustained inward currents in ganglion cells that appeared synaptic in origin because, unlike transient currents, sustained currents were blocked by inhibiting synaptic transmission with Cd2+. These synaptic currents reversed around ECl and were blocked by picrotoxin, strychnine, or both, suggesting they were mediated by GABAa/c and glycine receptors. Synaptic currents were also blocked by the NMDA antagonist MK801 and the KA/AMPA antagonist NBQX, suggesting that epiretinal stimulation evoked glutamate release from bipolar cells, which in turn stimulated the release of GABA and glycine from amacrine cells. Sustained currents were also evoked by epiretinal stimulation in bipolar cells. These currents reversed near ECl and were blocked by picrotoxin, suggesting they arose from GABAa/c receptors. CONCLUSIONS: Pulse duration is an important parameter for effective activation of the inner retina by epiretinal stimulation. Brief pulses evoke action potentials only in ganglion cells. However, longer pulses also evoke sustained synaptic currents by stimulating glutamate release from bipolar cell terminals, which, in turn, evokes the release of GABA and glycine from amacrine cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159
Cited by
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Selective activation of bipolar cells and ganglion cells is possible by altering the stimulus waveforms (Freeman et al., 2010; Fried et al., 2006; Margalit and Thoreson, 2006).”
High-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5138-07.2008 · Cited by 194
“Similar findings have been reported previously in tiger salamander retina (Margalit and Thoreson, 2006).”
ResultBoinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
“Keywords: epiretinal, subretinal, intraretinal stimulation, retinal prostheses, stimulation selectivity S Online supplementary data available from stacks.iop.org/JNE/11/026008/mmedia (Some figures may appear in colour only in the online journal)”
BackgroundImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
“Besides electrode size, pulse width may be important for controlling the form of the percept by altering the balance between stimulation of axons, RGC axon initial segment and the inner retina [14], [ 15 ].”
BackgroundJepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
“It has been well established that shorter pulses preferentially elicit direct RGC responses in comparison with longer pulses (Greenberg, 1998; Fried et al., 2006; Margalit and Thoreson, 2006; Ahuja et al., 2008).”
BackgroundStimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
“To record the responses of inner retinal neurons, retinal slice preparations have been used to gain access to the cells (Margalit and Thoreson, 2006; Cameron et al., 2013).”
MethodThe response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38
Metadata
- Authors
- Margalit, E., & Thoreson, W. B.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-06-01
- Volume
- 47
- Issue
- 6
- Pages
- 2606
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1979353221
- Cited by
- 81
- References
- 3
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.