Testing of Semichronically Implanted Retinal Prosthesis by Suprachoroidal-Transretinal Stimulation in Patients with Retinitis Pigmentosa

Fujikado, Takashi, Kamei, Motohiro, Sakaguchi, Hirokazu, Kanda, Hiroyuki, Morimoto, Takeshi, Ikuno, Yasushi, Nishida, Kentaro, Kishima, Haruhiko, Maruo, Tomoyuki, Konoma, Kunihiko, Ozawa, Motoki, Nishida, Kohji · 2011 · Investigative Opthalmology & Visual Science
Cited by 216

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To examine the safety and effectiveness of a retinal prosthesis that is implanted semichronically in two patients with advanced retinitis pigmentosa (RP). METHODS: Two eyes of two patients with advanced RP had a retinal prosthesis implanted in a sclera pocket of one eye. The visual acuity of both eyes before the implantation was bare light perception. Phosphenes were elicited by suprachoroidal-transretinal stimulation (STS). The internal devices of the STS were implanted under the skin on the temporal side of the head, and the 49 electrode-array was implanted in the scleral pocket of one eye. Biphasic electrical pulses (duration, 0.5 ms; frequency, 20 Hz) were delivered through nine active electrodes. The threshold current was determined by currents ≤1 mA. Behavioral tasks were used to determine the functioning of the prosthesis. RESULTS: The surgery was completed without a retinal detachment and retinal/vitreous hemorrhage. The implanted STS system remained functional for the 4-week test period. Phosphenes were elicited by currents delivered through six electrodes in Patient 1 and through four electrodes in Patient 2. The success of discriminating two bars was better than the chance level in both patients. In Patient 2, the success of a grasping task was better than the chance level, and the success rate of identifying a white bar on a touch panel increased with repeated testing. CONCLUSIONS: Semichronic implantation of a microelectrode-STS system showed that it was safe and remained functional for at least 4 weeks in two patients with advanced RP. (www.umin.ac.jp/ctr number, R000002690.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-6836

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., Ozawa, M., & Nishida, K.
Venue
Investigative Opthalmology & Visual Science
Published
2011-06-30
Volume
52
Issue
7
Pages
4726
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2021851162
Cited by
216
References
4
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.