Nonlinear Optical Macroscopic Assessment of 3-D Corneal Collagen Organization and Axial Biomechanics
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
PURPOSE: To characterize and quantify the collagen fiber (lamellar) organization of human corneas in three dimensions by using nonlinear optical high-resolution macroscopy (NLO-HRMac) and to correlate these findings with mechanical data obtained by indentation testing of corneal flaps. METHODS: Twelve corneas from 10 donors were studied. Vibratome sections, 200 μm thick, from five donor eyes were cut along the vertical meridian from limbus to limbus (arc length, 12 mm). Backscattered second harmonic-generated (SHG) NLO signals from these sections were collected as a series of overlapping 3-D images, which were concatenated to form a single 3-D mosaic (pixel resolution: 0.44 μm lateral, 2 μm axial). Collagen fiber intertwining was quantified by determining branching point density as a function of stromal depth. Mechanical testing was performed on corneal flaps from seven additional eyes. Corneas were cut into three layers (anterior, middle, and posterior) using a femtosecond surgical laser system and underwent indentation testing to determine the elastic modulus for each layer. RESULTS: The 3-D reconstructions revealed complex collagen fiber branching patterns in the anterior cornea, with fibers extending from the anterior limiting lamina (ALL, Bowman's layer), intertwining with deeper fibers and reinserting back to the ALL, forming bow spring-like structures. Measured branching-point density was four times higher in the anterior third of the cornea than in the posterior third and decreased logarithmically with increasing distance from the ALL. Indentation testing showed an eightfold increase in elastic modulus in the anterior stroma. CONCLUSIONS: The axial gradient in lamellar intertwining appears to be associated with an axial gradient in the effective elastic modulus of the cornea, suggesting that collagen fiber intertwining and formation of bow spring-like structures provide structural support similar to cross-beams in bridges and large-scale structures. Future studies are necessary to determine the role of radial and axial structural-mechanical heterogeneity in controlling corneal shape and in the development of keratoconus, astigmatism, and other refractive errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024 · cited 1×
“Changes in corneal curvature after local stiffening have been observed in keratoconus corneas after corneal cross-linking treatment.(33) Wollensak(34) observed local flattening in areas of keratoconus corneas with increased rigidity after undergoing UV cross-linking treatment compared to the untreated, structurally co…”
BackgroundA mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967 · cited 3×
“A linear increase in indentation force indicates full contact between the flat end of the probe and the corneal flap.19 Force-displacement curves were generated for each spot and used to calculate the effective elastic modulus, using Hayes’ equation19 which also applies to soft biologic tissue20: where E is the effect…”
MethodInfluentialNature designs tough collagen: Explaining the nanostructure of collagen fibrils
Buehler, M. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603216103 · Cited by 803
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Crosslinking treatment of progressive keratoconus: new hope
Wollensak, G. (2006) · Current Opinion in Ophthalmology · doi:10.1097/01.icu.0000233954.86723.25 · Cited by 711
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708 · cited 2×
“This method is used to measure compliance in biological soft tissues and is a well-established way of characterizing the nanoelastic properties of various ocular tissues.16,17 A more detailed description of indentation testing is provided by McKee et al.18 Briefly, a sample is indented with a probe of known diameter a…”
Method(1991) · PubMed · Cited by 678
Histology of the Human Eye: An Atlas and Textbook
(1972) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1972.tb88227.x · Cited by 634 · cited 1×
“These patterns are consistent with the classic model described in the literature of orthogonally arranged sheets of fibers.(27,28) About halfway through the stroma, collagen fibers branch more frequently.”
ResultKohlhaas, M., Spoerl, E., Schilde, T., Unger, G., Wittig, C., & Pillunat, L. E. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.12.092 · Cited by 447 · cited 2×
“This observation matches data published by Kohlhaas et al.30 obtained through extensometry measurements of corneal strips, which also show a stiffer anterior stroma.”
ResultThe specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424 · cited 4×
“Swelling studies conducted by Müller et al.(24) show increased resistance to swelling, even in extreme hydration states for the anterior stroma.”
BackgroundInfluential
Cited by
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853
“It seems that the anchoring lamellae enter the cornea from the sclera, and may work their way towards the corneal surface without reaching the central optical zone (Abass et al., 2015; Winkler et al., 2011).”
BackgroundThree-dimensional distribution of transverse collagen fibers in the anterior human corneal stroma
Winkler, M., Shoa, G., Xie, Y., Petsche, S. J., Pinsky, P. M., Juhasz, T., Brown, D. J., & Jester, J. V. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-13150 · Cited by 152
“The reduction in fiber angle range and transverse fiber percentage with increasing stromal depth matches the reduction in branching point density observed previously.(19)”
BackgroundMethodInfluentialSelf-citationTransverse depth-dependent changes in corneal collagen lamellar orientation and distribution
Abass, A., Hayes, S., White, N., Sorensen, T., & Meek, K. M. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0717 · Cited by 78
“Even without any image processing, the differences previously described between anterior and posterior stroma [3] are evident, with many out-of-plane lamellae in the anterior stroma gradually transforming to lamellae parallel to the anterior surface in the posterior stroma.”
BackgroundInfluentialA comparative study of vertebrate corneal structure: the evolution of a refractive lens
Winkler, M., Shoa, G., Tran, S. T., Xie, Y., Thomasy, S., Raghunathan, V. K., Murphy, C., Brown, D. J., & Jester, J. V. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16584 · Cited by 50
“Images were generated following previously established protocols for HRMac.(3,4) Briefly, eyes were perfusion fixed under pressure with 2% paraformaldehyde in PBS (pH 7.”
BackgroundMethodSelf-citationCrimp around the globe; patterns of collagen crimp across the corneoscleral shell
Jan, N.-J., Brazile, B. L., Hu, D., Grube, G., Wallace, J., Gogola, A., & Sigal, I. A. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.04.003 · Cited by 47
“, 1996; Ostrin and Wildsoet, 2016), electron microscopy (Andreo and Farrell, 1982), nonlinear microscopy (Kamma-Lorger et al., 2010; Mega et al., 2012; Midgett et al., 2016; Winkler et al., 2011; Zyablitskaya et al., 2017), and MRI(Ho et al.”
Structural control of corneal transparency, refractive power and dynamics
Meek, K. M., Knupp, C., Lewis, P. N., Morgan, S. R., & Hayes, S. (2025) · Eye · doi:10.1038/s41433-024-02969-7 · Cited by 45
Pijanka, J. K., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813022358 · Cited by 38
“…and scleral architecture have used imaging modalities such as transmission and scanning electron microscopy (Komai & Ushiki, 1991; Yamamoto et al., 2000), atomic force microscopy (Yamamoto et al., 1999) and second harmonic generation multiphoton microscopy (Han et al., 2005; Winkler et al., 2011).”
Method
Metadata
- Authors
- Winkler, M., Chai, D., Kriling, S., Nien, C. J., Brown, D. J., Jester, B., Juhasz, T., & Jester, J. V.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-11-11
- Volume
- 52
- Issue
- 12
- Pages
- 8818
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2102772179
- Cited by
- 204
- References
- 33
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.