In vitro modeling of the microvascular occlusion and thrombosis that occur in hematologic diseases using microfluidic technology
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In hematologic diseases, such as sickle cell disease (SCD) and hemolytic uremic syndrome (HUS), pathological biophysical interactions among blood cells, endothelial cells, and soluble factors lead to microvascular occlusion and thrombosis. Here, we report an in vitro "endothelialized" microfluidic microvasculature model that recapitulates and integrates this ensemble of pathophysiological processes. Under controlled flow conditions, the model enabled quantitative investigation of how biophysical alterations in hematologic disease collectively lead to microvascular occlusion and thrombosis. Using blood samples from patients with SCD, we investigated how the drug hydroxyurea quantitatively affects microvascular obstruction in SCD, an unresolved issue pivotal to understanding its clinical efficacy in such patients. In addition, we demonstrated that our microsystem can function as an in vitro model of HUS and showed that shear stress influences microvascular thrombosis/obstruction and the efficacy of the drug eptifibatide, which decreases platelet aggregation, in the context of HUS. These experiments establish the versatility and clinical relevance of our microvasculature-on-a-chip model as a biophysical assay of hematologic pathophysiology as well as a drug discovery platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, microfluidic devices (i.e. thrombosis-on-chip devices) are of interest to mimic a range of flows and shear stresses, starting from low (i.e. in veins) to high values (i.e. in arteries) [287–290].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices possess endothelialized lumen that can reliably capture several features of blood vessels such as atherosclerosis (i.e. fatty plaque deposition and formation) and bifurcations (i.e. branches and bends) by changing the channel geometries and flow patterns, ranging from laminar steady flow to pulsatile flow [287–290,295–304].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moake, J. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmra020528 · Cited by 1,221
Self-citationPathogenesis and Treatment of Sickle Cell Disease
Bunn, H. F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371107 · Cited by 1,154
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Vestweber (2008) · doi:10.1161/atvbaha.107.158014 · Cited by 806
Adhesion Mechanisms in Platelet Function
Ruggeri, Z. M., & Mendolicchio, G. L. (2007) · Circulation Research · doi:10.1161/01.res.0000267878.97021.ab · Cited by 755
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Mechanics of Stimulated Neutrophils: Cell Stiffening Induces Retention in Capillaries
Worthen, G. S., Schwab, B., Elson, E. L., & Downey, G. P. (1989) · Science · doi:10.1126/science.2749255 · Cited by 597
Cited by
Items 101–200 of 297
Application of microfluidic devices in studies of thrombosis and hemostasis
Zhang, C., & Neelamegham, S. (2017) · Platelets · doi:10.1080/09537104.2017.1319047 · Cited by 45
Shiga toxin-associated hemolytic uremic syndrome
Petruzziello-Pellegrini, T. N., & Marsden, P. A. (2012) · Current Opinion in Nephrology & Hypertension · doi:10.1097/mnh.0b013e328354a62e · Cited by 39
Tissue‐Engineered Microvessels: A Review of Current Engineering Strategies and Applications
Zhao, N., Pessell, A. F., Zhu, N., & Searson, P. C. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303419 · Cited by 43
In microfluidico: Recreating in vivo hemodynamics using miniaturized devices
Zhu, S., Herbig, B. A., Li, R., Colace, T. V., Muthard, R. W., Neeves, K. B., & Diamond, S. L. (2016) · Biorheology · doi:10.3233/bir-15065 · Cited by 43
Greineder, C. F., Johnston, I. H., Villa, C. H., Gollomp, K. L., Esmon, C. T., Cines, D. B., Poncz, M., & Muzykantov, V. R. (2017) · Blood Advances · doi:10.1182/bloodadvances.2017007229 · Cited by 45
Chen, C., Chen, Y., Huang, J., & Wu, Y. (2014) · Molecular Human Reproduction · doi:10.1093/molehr/gau062 · Cited by 39
“…further inflammatory reaction, since the severe inflammatory reaction associated with neutrophil activation may damage placental tissue due to excessive ROS production and formation of leukocyte aggregates that lead to occlusion of blood flow in the placental microvasculature (Tsai et al., 2012).”
BackgroundSelf-citationOrganoids, organs-on-chips and other systems, and microbiota
May, S., Evans, S., & Parry, L. (2017) · Emerging Topics in Life Sciences · doi:10.1042/etls20170047 · Cited by 36
Vascularized Microfluidics and the Blood–Endothelium Interface
Hesh, C. A., Qiu, Y., & Lam, W. A. (2019) · Micromachines · doi:10.3390/mi11010018 · Cited by 44
“Some have stopped using PDMS-based hybrid models altogether instead opting for the use of only collagen [29], fibrin [189], agarose [190] or alginate [191], which allow the tuning of stiffness and permeability.”
BackgroundInfluentialSelf-citationMicrofluidics in Haemostasis: A Review
Panchal, H. J., Kent, N. J., Knox, A. J. S., & Harris, L. F. (2020) · Molecules · doi:10.3390/molecules25040833 · Cited by 38
“The vasculature on a chip provides an ideal physiological environment to study different cell interactions, blood rheology in physiologically relevant channel sizes and the biochemical and biophysical processes responsible for multiple haemostasis-related disorders [34].”
BackgroundMethodMASP-1 of the complement system enhances clot formation in a microvascular whole blood flow model
Jenny, L., Dobó, J., Gál, P., Pál, G., Lam, W. A., & Schroeder, V. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191292 · Cited by 35
“reported the development of a microfluidic model which accurately simulates microvascular blood vessels in a way that is very close to human physiology [19].”
BackgroundSelf-citationBertulli, C., Gerigk, M., Piano, N., Liu, Y., Zhang, D., Müller, T., Knowles, T. P. J., & Huang, Y. Y. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-30776-0 · Cited by 36
Druzak, S., Iffrig, E., Roberts, B. R., Zhang, T., Fibben, K. S., Sakurai, Y., Verkerke, H., Rostad, C. A., Chahroudi, A., Schneider, D., et al. (2022) · Nature Communications · doi:10.1038/s41467-023-37269-3 · Cited by 40
Self-citationBeyond Thrombosis: the Role of Platelets in Pulmonary Hypertension
Nicoleau, S., & Wójciak‐Stothard, B. (2020) · SciMedicine Journal · doi:10.28991/scimedj-2020-0204-7 · Cited by 38
Li, X., Xu, S., He, P., & Liu, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0126797 · Cited by 34
Engineered Microvessels for the Study of Human Disease
Rayner, S. G., & Zheng, Y. Y. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034428 · Cited by 33
White, J. U., Lancelot, M. M., Sarnaik, S. A., & Hines, P. C. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141847 · Cited by 33
“Microfluidic-based assays have been used more recently to study SSRBC adhesion [18], and offer the advantage of smaller blood and reagent requirements, shorter set-up time, improved standardization, and a more physiologic microenvironment [7, 14, 40, 48].”
MethodDeoxygenation Reduces Sickle Cell Blood Flow at Arterial Oxygen Tension
Lu, X., Wood, D. K., & Higgins, J. M. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2016.04.050 · Cited by 35
“The adhesive processes absent from our system would only amplify the effects we have seen, as has been shown under conditions of constant high oxygen tension (9,34).”
BackgroundWhy platelet mechanotransduction matters for hemostasis and thrombosis
Oshinowo, O. T., Azer, S., Lin, J., & Lam, W. A. (2023) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2023.06.010 · Cited by 33
Self-citationEndothelial cell culture in microfluidic devices for investigating microvascular processes
Mannino, R. G., Qiu, Y., & Lam, W. A. (2018) · Biomicrofluidics · doi:10.1063/1.5024901 · Cited by 37
Self-citationXu, T., Lizarralde-Iragorri, M. A., Roman, J., Ghasemi, R., Lefèvre, J.-P., Martincic, E., Brousse, V. A. M., Français, O., Nemer, W. E., & Pioufle, B. L. (2020) · Scientific Reports · doi:10.1038/s41598-020-66693-4 · Cited by 34
Mangin, P., Neeves, K. B., Lam, W. A., Cosemans, J. M. E. M., Korin, N., Kerrigan, S. W., & Panteleev, M. A. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15143 · Cited by 32
Self-citationXu, Y., Yu, G., Nie, R., & Wu, Z. (2022) · Open Research (University of Surrey) · doi:10.1002/viw.20200183 · Cited by 34
Carden, M. A., Fay, M. E., Sakurai, Y., McFarland, B., Blanche, S., DiPrete, C., Joiner, C. H., Sulchek, T., & Lam, W. A. (2017) · Microcirculation · doi:10.1111/micc.12353 · Cited by 32
Self-citationBal‐Öztürk, A., Miccoli, B., Avci‐Adali, M., Mogtader, F., Sharifi, F., Çeçen, B., Yaşayan, G., Braeken, D., & Alarçın, E. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666190206195304 · Cited by 30
Emerging Microfluidic Approaches for Platelet Mechanobiology and Interplay With Circulatory Systems
Zhang, Y., Ramasundara, S. D. Z., Preketes-tardiani, R. E., Cheng, V., Lu, H., & Ju, L. A. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.766513 · Cited by 30
“Furthermore, single-layered microfluidics can emulate more complex vessel structures, such as bifurcation (39), 2D stenosis (46), network (47), and micropost array (40) to recapitulate flow disturbance induced platelet activation, adhesion, contraction and aggregation (48, 49).”
BackgroundMathur, T., Tronolone, J. J., & Jain, A. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.022795 · Cited by 32
Micro-elastometry on whole blood clots using actuated surface-attached posts (ASAPs)
Judith, R. M., Fisher, J. K., Spero, R. C., Fiser, B. L., Turner, A. W., Oberhardt, B. J., Taylor, R. M., Falvo, M. R., & Superfine, R. (2015) · Lab on a Chip · doi:10.1039/c4lc01478b · Cited by 27
Shin, Y., Lim, S., Kim, J., Jeon, J. S., Yoo, H., & Gweon, B. (2019) · Lab on a Chip · doi:10.1039/c9lc00352e · Cited by 26
Aich, A., Lamarre, Y., Sacomani, D. P., Kashima, S. H., Covas, D. T., & de la Torre, L. G. (2021) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.558982 · Cited by 29
Origins and functional differences of blood endothelial cells
Ng, C., & Cheung, C. (2023) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2023.05.001 · Cited by 30
Impact of platelet transfusions in children with post-diarrheal hemolytic uremic syndrome
Balestracci, A., Martin, S. M., Toledo, I., Alvarado, C., & Wainsztein, R. E. (2013) · Pediatric Nephrology · doi:10.1007/s00467-013-2414-y · Cited by 26
Nanodiagnostics, Nanopharmacology and Nanotoxicology of Platelet–Vessel Wall Interactions
Tomaszewski, K. A., Radomski, M. W., & Santos-Martínez, M. J. (2015) · Nanomedicine · doi:10.2217/nnm.14.232 · Cited by 28
Schoeman, R. M., Lehmann, M., & Neeves, K. B. (2017) · Platelets · doi:10.1080/09537104.2017.1306042 · Cited by 34
Manufacturing of poly(ethylene glycol diacrylate)-based hollow microvessels using microfluidics
Aykar, S. S., Reynolds, D. E., McNamara, M. C., & Hashemi, N. N. (2020) · RSC Advances · doi:10.1039/c9ra10264g · Cited by 21
“41,42 In our micro uidic device, though, we have set out to exclude the manual rolling of lms and complex cell-seeding procedures and produce a simple platform for generating hollow synthetic multiaxial microvessels.”
Manz, X. D., Albers, H. J., Symersky, P., Aman, J., van der Meer, A. D., Bogaard, H. J., & Szulcek, R. (2020) · Journal of Visualized Experiments · doi:10.3791/61068 · Cited by 30
In vitro microfluidic model for the study of vaso-occlusive processes
Dominical, V. M., Vital, D. M., O’Dowd, F., Saad, S. T. O., Costa, F. F., & Conran, N. (2014) · Experimental Hematology · doi:10.1016/j.exphem.2014.10.015 · Cited by 24
Lu, X., Chaudhury, A., Higgins, J. M., & Wood, D. K. (2018) · American Journal of Hematology · doi:10.1002/ajh.25227 · Cited by 26
Valdez, J. M., Datta, Y. H., Higgins, J. M., & Wood, D. K. (2019) · APL Bioengineering · doi:10.1063/1.5118212 · Cited by 26
Thromboinflammation Model-on-A-Chip by Whole Blood Microfluidics on Fixed Human Endothelium
Dupuy, A., Hagimola, L., Mgaieth, N. S. A., Houlahan, C. B., Preketes-tardiani, R. E., Coleman, P. R., & Passam, F. H. (2021) · Diagnostics · doi:10.3390/diagnostics11020203 · Cited by 29
“HUVEC, HLMVEC-lined 3D branching microchannels TNF-α, STX2 Heparin, EDTA whole blood Platelet, neutrophil and monocyte adhesion Study of microvascular occlusion in sickle cell disease and HUS and effect of medications [30]”
BackgroundMethodLu, X., Galarneau, M., Higgins, J. M., & Wood, D. K. (2017) · Microcirculation · doi:10.1111/micc.12357 · Cited by 25
Apostoli, A., Bianchi, V., Bono, N., Dimasi, A., Ammann, K. R., Moiia, Y. R., Montisci, A., Sheriff, J., Bluestein, D., Fiore, G. B., et al. (2019) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2019.02.009 · Cited by 25
Integrating microfluidics, hydrogels, and 3D bioprinting for personalized vessel-on-a-chip platforms
Aye, S. S. S., Fang, Z., Wu, M. C. L., Lim, K. S., & Ju, L. A. (2025) · Biomaterials Science · doi:10.1039/d4bm01354a · Cited by 28
Embedded macrophages induce intravascular coagulation in 3D blood vessel-on-chip
Middelkamp, H. H. T., Weener, H. J., Gensheimer, T., Vermeul, K., de Heus, L. E., Albers, H. J., van den Berg, A., & van der Meer, A. D. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00684-w · Cited by 27
“(Albers et al. 2019; Barrile et al. 2018; Costa et al. 2017; van Dijk et al. 2020; Hasan et al. 2015; Jia et al. 2019; Mannino et al. 2015; Tsai et al. 2012; Westein et al. 2013; Zheng et al. 2012).”
Lee, J., Kumar, A., Mathur, T., & Jain, A. (2025) · Lab on a Chip · doi:10.1039/d4lc00968a · Cited by 24
Choi, J. S., & Seo, T. S. (2019) · Biomicrofluidics · doi:10.1063/1.5068689 · Cited by 23
Zhang, S., Xu, G., Wu, J., Liu, X., Fan, Y. Z., Chen, J., Wallace, G. G., & Gu, Q. (2023) · Small Methods · doi:10.1002/smtd.202300685 · Cited by 28
Quantitative microfluidic fluorescence microscopy to study vaso-occlusion in sickle cell disease
Jimenez, M. A., Tütüncüoğlu, E., Barge, S., Novelli, E. M., & Sundd, P. (2015) · Haematologica · doi:10.3324/haematol.2015.126631 · Cited by 21
“However, these approaches were limited by the use of isolated SS-RBCs(10) or the inability to visualize cellular interactions at single cell resolution(11) and distinguish different cell types that constitute the vaso-occlusive plug.(8) We introduce qMFM (Figure 1), which enables visualization of molecular interaction…”
BackgroundCompatibility analysis of 3D printer resin for biological applications
Sivashankar, S., Agambayev, S., Alamoudi, K. O., Buttner, U., Khashab, N. M., & Salama, K. N. (2016) · Micro & Nano Letters · doi:10.1049/mnl.2016.0530 · Cited by 22
Versatile Vessel-on-a-Chip Platform for Studying Key Features of Blood Vascular Tumors
Llenas, M., Paoli, R., Feiner‐Gracia, N., Albertazzi, L., Samitier, J., & Caballero, D. (2021) · Bioengineering · doi:10.3390/bioengineering8060081 · Cited by 23
“The inherent advantages of microfluidics and organ-on-a-chip technology allow the investigation of these vascular injury events in a well-controlled dynamic environment to assess the biological, biochemical, and biophysical components of the native scenario [22,30,31].”
BackgroundBiomimetic epithelium/endothelium on chips
Lin, L., Wang, X., Niu, M., Wu, Q., Wang, H., Zu, Y., & Wang, W. (2022) · Engineered Regeneration · doi:10.1016/j.engreg.2022.05.001 · Cited by 24
Huang, J., Kim, J., Ding, Y., Jayaraman, A., & Ugaz, V. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073188 · Cited by 20
“constructed using conventional lithography and molding approaches [6,8,32,33], the microchannels in every branch generation inherently retain identical channel heights.”
MethodSelf-citationDynamic interactions ofPlasmodiumspp. with vascular endothelium
Gillrie, M. R., & Ho, M. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1268667 · Cited by 26
“Microfluidic models have also allowed for analysis of cellular interactions within microvascular networks (10–100mm) using either de novo generated vascular networks in 3D matrices(151) or in patterned devices devoid of matrices.(152) The microfluidic models would be ideal for studying endothelial-IRBC interactions in…”
MethodMicrotechnologies for Cell Microenvironment Control and Monitoring
Azuaje‐Hualde, E., García-Hernando, M., Etxebarria‐Elezgarai, J., de Pancorbo, M. M., Benito‐Lopez, F., & Basabe‐Desmonts, L. (2017) · Micromachines · doi:10.3390/mi8060166 · Cited by 21
“, in blood vessels [45], and to be able to control those in microfluidics is very important.”
BackgroundChallenges and Opportunities Toward Enabling Phenotypic Screening of Complex and 3D Cell Models
Horman, S. R., Hogan, C. J., Reyes, K. D., Lo, F., & Antczak, C. (2015) · Future Medicinal Chemistry · doi:10.4155/fmc.14.163 · Cited by 24
Pan, C., Xu, J., Gao, Q., Li, W., Sun, T., Lu, J., Shi, Q., Han, Y., Gao, G., & Li, J. (2023) · Biofabrication · doi:10.1088/1758-5090/aceffa · Cited by 19
Williams, D. C., & Wood, D. K. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2313755120 · Cited by 20
“Prior studies have explored the processes involved in hemoglobin S polymerization (28, 29), and there have been a multitude of in - vitro studies recreating the pathological flow behavior and vascular damage introduced by polymer - containing RBCs (16, 30, 31).”
Zhao, Y. C., Wang, Z., Zhao, H., Yap, N. A., Wang, R., Cheng, W., Xu, X., & Ju, L. A. (2025) · ACS Sensors · doi:10.1021/acssensors.4c02764 · Cited by 21
A vascular injury model using focal heat-induced activation of endothelial cells
Sylman, J. L., Artzer, D. T., Rana, K., & Neeves, K. B. (2015) · Integrative Biology · doi:10.1039/c5ib00108k · Cited by 21
Cho, M., & Park, J. (2021) · Micromachines · doi:10.3390/mi12121528 · Cited by 21
“Various tissues, such as blood vessels [10,11], heart [12], liver [13,14], lung [15], and intestine [16], have been mimicked and studied using microfluidics.”
BackgroundInteraction of Shiga Toxin with the A-domains and Multimers of von Willebrand Factor
Lo, N. C., Turner, N. A., Crúz, M. A., & Moake, J. L. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.487413 · Cited by 19
Self-citationKucukal, E., Man, Y., Gurkan, U. A., & Schmidt, B. E. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4050647 · Cited by 17
Zhang, Y., Jiang, F., Chen, Y., & Ju, L. A. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.779753 · Cited by 17
Development of Organs-on-Chips and Their Impact on Precision Medicine and Advanced System Simulation
Luo, Y., Li, X., Zhao, Y., Zhong, W., Xing, M. M. Q., & Lyu, G. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15082094 · Cited by 18
Model Systems to Study the Mechanism of Vascular Aging
van der Linden, J., Trap, L., Scherer, C. V., Roks, A. J. M., Danser, A. H. J., van der Pluijm, I., & Cheng, C. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242015379 · Cited by 19
Total Synthesis of a PSGL-1 Glycopeptide Analogue for Targeted Inhibition of P-Selectin
Dhakal, B., Mandhapati, A. R., Eradi, P., Park, S. J., Fibben, K. S., Li, K., DeYong, A. E., Escopy, S., Karki, G., Park, D., et al. (2024) · Journal of the American Chemical Society · doi:10.1021/jacs.4c05090 · Cited by 18
Self-citationAn Experimental-Computational Approach to Quantify Blood Rheology in Sickle Cell Disease
Bazzi, M. S., Valdez, J. M., Barocas, V. H., & Wood, D. K. (2020) · Biophysical Journal · doi:10.1016/j.bpj.2020.10.011 · Cited by 18
Khanna, A., Oropeza, B. P., & Huang, N. F. (2023) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37602 · Cited by 22
Microvascular platforms for the study of platelet-vessel wall interactions
Zheng, Y. Y., Chen, J., & López, J. A. (2014) · Thrombosis Research · doi:10.1016/j.thromres.2013.12.039 · Cited by 18
“nels with bifurcations and junctions [30].”
Utility of microfluidic devices to study the platelet–endothelium interface
Zilberman‐Rudenko, J., Sylman, J. L., Garland, K. S., Puy, C., Wong, A. D., Searson, P. C., & McCarty, O. J. T. (2017) · Platelets · doi:10.1080/09537104.2017.1280600 · Cited by 18
Truesdell, S. L., & Saunders, M. M. (2019) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2020063 · Cited by 21
Hematocrit significantly confounds diffuse correlation spectroscopy measurements of blood flow
Sathialingam, E., Williams, E. K., Lee, S. Y., McCracken, C., Lam, W. A., & Buckley, E. M. (2020) · Biomedical Optics Express · doi:10.1364/boe.397613 · Cited by 17
Self-citation3D spheroid-microvasculature-on-a-chip for tumor-endothelium mechanobiology interplay
Zhang, Y., Jiang, F., Zhao, Y. C., Cho, A., Fang, G., Cox, C. D., Zreiqat, H., Lu, Z. F., Lu, H., & Ju, L. A. (2023) · Biomedical Materials · doi:10.1088/1748-605x/ace7a4 · Cited by 15
Cushman, M., Barnes, G. D., Creager, M. A., Diaz, J. A., Henke, P. K., Machlus, K. R., Nieman, M. T., & Wolberg, A. S. (2020) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12373 · Cited by 20
Bioprinting of three-dimensional culture models and organ-on-a-chip systems
Huang, Y. Y. S., Zhang, D., & Liu, Y. (2017) · MRS Bulletin · doi:10.1557/mrs.2017.163 · Cited by 15
Pinheiro, E. A., Magdy, T., & Burridge, P. W. (2020) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-020-09962-x · Cited by 15
Mannino, R. G., Pandian, N. K. R., Jain, A., & Lam, W. A. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.11.006 · Cited by 19
Self-citationLaboratory Assessment of Coagulation Factor XIII
Schroeder, V. (2020) · Hämostaseologie · doi:10.1055/a-1181-0327 · Cited by 14
Carman, C. V., Nikova, D. N., Sakurai, Y., Shi, J., Novakovic, V. A., Rasmussen, J. T., Lam, W. A., & Gilbert, G. E. (2022) · Blood Advances · doi:10.1182/bloodadvances.2021006870 · Cited by 14
“55 Thus, we used standard lithographic techniques to fabricate polydiethylsiloxane microchannels with dimensions comparable to postcapillary venules.”
Self-citationPhysiochemical artifacts in FeCl3 thrombosis models
Neeves, K. B. (2015) · Blood · doi:10.1182/blood-2015-05-644708 · Cited by 14
“The same group used this approach to model hemolytic uremic syndrome.(7) Others have recreated vessel geometries characteristic of stenosed vessels(8) and even entire vascular networks such as the circle of Willis.”
Wang, J., Tu, Q., Wang, Y., Liu, W., Liu, R., Shen, S., Xu, J., Zhao, L. Q., & Wang, J. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1172-2 · Cited by 15
“2012), and thrombosis (Tsai et al. 2012) to leukocyte/cancer cell–endothelium interactions (Yang et al.”
BackgroundRECAPITULATING THE VASCULAR MICROENVIRONMENT IN MICROFLUIDIC PLATFORMS
Abaci, H. E., Drazer, G., & Gerecht, S. (2013) · Nano LIFE · doi:10.1142/s1793984413400011 · Cited by 15
Advancements and Future Perspectives of Microfluidic Technology in Pediatric Healthcare
Zhang, X., Liu, A., Wang, Y., Niu, C., Rong, X., Jia, C., Sun, J., Song, S., Zhang, L., Ye, F., et al. (2025) · Smart Medicine · doi:10.1002/smmd.70018 · Cited by 18
“A research group from the United States has introduced an in vitro microfluidic model of the microvasculature aimed at investigating blood disorders such as sickle cell disease (SCD) and hemolytic‐uremic syndrome (HUS) (Figure 7B) [105].”
Integrating in vitro organ-specific function with the microcirculation
Moya, M. L., & George, S. C. (2014) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2013.12.004 · Cited by 16
Sickle Cell Disease Pathophysiology and Related Molecular and Biophysical Biomarkers
Saah, E. N., Fadaei, P., Gurkan, U. A., & Sheehan, V. (2022) · Hematology/Oncology Clinics of North America · doi:10.1016/j.hoc.2022.06.005 · Cited by 16
Tasadduq, B., Wang, G., Banani, M. E., Mao, W., Lam, W. A., Alexeev, A., & Sulchek, T. (2015) · Flow Measurement and Instrumentation · doi:10.1016/j.flowmeasinst.2015.06.018 · Cited by 13
Self-citationMicroengineered Vascular Systems for Drug Development
Hovell, C. M., Sei, Y. J., & Kim, Y. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214560767 · Cited by 15
“Tsai et al.(23) featured a model using whole blood flowing through bifurcations in microfluidic devices seeded with either HUVECs or human lung microvascular endothelial cells (HLMVECs; Fig.”
BackgroundMethodInfluentialClinical Implications of Single-Cell Microfluidic Devices for Hematological Disorders
Hansen, C. E., & Lam, W. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01013 · Cited by 13
Self-citationJenny, L., Melmer, A., Laimer, M. W., Hardy, E. T., Lam, W. A., & Schroeder, V. (2020) · Diabetes and Vascular Disease Research · doi:10.1177/1479164120903044 · Cited by 14
Self-citationCuartas-Vélez, C., Middelkamp, H. H. T., van der Meer, A. D., van den Berg, A., & Bosschaart, N. (2023) · Biomedical Optics Express · doi:10.1364/boe.500434 · Cited by 14
The Biofabrication of Diseased Artery In Vitro Models
Pan, C., Gao, Q., Kim, B. S., Han, Y., & Gao, G. (2022) · Micromachines · doi:10.3390/mi13020326 · Cited by 15
“fabricated an “endothelialized” vascular OoC, which reproduced and integrated a set of pathophysiological processes such as thrombosis [79].”
BackgroundFabrication of a modular hybrid chip to mimic endothelial-lined microvessels in flow conditions
Pitingolo, G., Vecchione, R., Falanga, A. P., Guarnieri, D., & Netti, P. A. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa5a79 · Cited by 12
Straight Channel Microfluidic Chips for the Study of Platelet Adhesion under Flow
Dupuy, A., Ju, L. A., & Passam, F. H. (2019) · BIO-PROTOCOL · doi:10.21769/bioprotoc.3195 · Cited by 12
“…material which has been widely used to create microfluidic channels with various geometries such as stenosis (Nesbitt et al., 2009; Tovar-Lopez et al., 2013), bifurcation (Tsai et al., 2012), aneurysm (Mannino et al., 2015), and spiral channels for two-dimensional cell sorting (Hou et al., 2016).”
The Platelet and the Biophysical Microenvironment: Lessons from Cellular Mechanics
Ciciliano, J. C., Tran, R., Sakurai, Y., & Lam, W. A. (2014) · Thrombosis Research · doi:10.1016/j.thromres.2013.12.037 · Cited by 12
“Several groups have reported “endothelialization” of microfluidics to recapitulate the microvasculature for system level studies of thrombosis, sickle cell disease, angiogenesis, and other disease processes [50-52].”
Self-citationMicrofluidics for investigating vaso‐occlusions in sickle cell disease
Horton, R. E. (2017) · Microcirculation · doi:10.1111/micc.12373 · Cited by 12
A Pulmonary Vascular Model From Endothelialized Whole Organ Scaffolds
Yuan, Y., Leiby, K. L., Greaney, A. M., Raredon, M. S. B., Qian, H., Schupp, J. C., Engler, A. J., Baevova, P., Adams, T. S., Kural, M. H., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.760309 · Cited by 15
“Recently, organoid and microfluidics-based in vitro culture systems have emerged as tools for modeling vascular diseases (Tsai et al., 2012; Qiu et al., 2018; Wimmer et al., 2019; Monteil et al., 2020).”
BackgroundMethodZhang, Y., Aye, S. S. S., Cheng, V., Nasser, A., Hong, T., Vatankhah, P., Jiang, F., Zhao, Y. C., Moldovan, L., Sun, A., et al. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202300234 · Cited by 14
Clot Accumulation in 3D Microfluidic Bifurcating Microvasculature Network
Belenkovich, M., Veksler, R., Kreinin, Y., Mekler, T., Flores, M., Sznitman, J., Holinstat, M. A., & Korin, N. (2024) · Micromachines · doi:10.3390/mi15080988 · Cited by 12
“…have recapitulated the human microvasculature geometry and physiology to investigate vessel–blood cell interactions, and specifically in bifurcating microvessels, [4,10,16], to our knowledge, all previous microvessel models were made with the same height and, thus, do not conserve the Murray’s law.”
BackgroundMethodResultInfluentialShayor, A. A., Kabir, M. E., Rifath, M. S. A., Rashid, A. B., & Oh, K. W. (2024) · Sensors · doi:10.3390/s24185872 · Cited by 14
Guarino, V., Perrone, E., Luca, E. D., Rainer, A., Cesaria, M., Zizzari, A. T., Bianco, M., Gigli, G., Moroni, L., & Arima, V. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202401804 · Cited by 11
Adjustable behaviors and dynamic mechanisms of droplets in the cross junction
Liu, Z., Wang, Z., Pang, Y., Su, P. F., & Wang, X. (2023) · Physics of Fluids · doi:10.1063/5.0175114 · Cited by 11
Metadata
- Authors
- Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Lam, Wilbur A.
- Venue
- Journal of Clinical Investigation
- Published
- 2012-01-03
- Volume
- 122
- Issue
- 1
- Pages
- 408-418
- ISSN
- 0021-9738 (ISSN-L)
- PMC
- PMC3248292
- OpenAlex
- W2134766290
- Cited by
- 297
- References
- 58
- Citations by year
- 2026: 13 · 2025: 18 · 2024: 11 · 2023: 23 · 2022: 19 · 2021: 25 · 2020: 25 · 2019: 19 · 2018: 20 · 2017: 33 · 2016: 21 · 2015: 22 · 2014: 26 · 2013: 12 · 2012: 9
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Investigation (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (CAREER)
- Emory University
- Children's Healthcare of Atlanta
- National Institutes of Health (NIH-R01)
- U.S. Public Health Service
- University of California, San Francisco
- National Heart, Lung, and Blood Institute (K08HL093360, U54HL112309)
- National Eye Institute (PN2EY018244)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
- Keywords
- microvascular occlusion, thrombosis, sickle cell disease, hemolytic uremic syndrome, hydroxyurea, eptifibatide, shear stress, platelet aggregation, in vitro disease model, drug discovery
- MeSH terms
- Eptifibatide, Anemia, Sickle Cell, Hematologic Diseases, Hemolytic-Uremic Syndrome, Humans, Hydroxyurea, Microscopy, Fluorescence, Models, Cardiovascular, Peptides, Platelet Aggregation Inhibitors, Thrombosis, Hemorheology, Microfluidic Analytical Techniques, Microvessels, Human Umbilical Vein Endothelial Cells, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.