In vitro modeling of the microvascular occlusion and thrombosis that occur in hematologic diseases using microfluidic technology
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In hematologic diseases, such as sickle cell disease (SCD) and hemolytic uremic syndrome (HUS), pathological biophysical interactions among blood cells, endothelial cells, and soluble factors lead to microvascular occlusion and thrombosis. Here, we report an in vitro "endothelialized" microfluidic microvasculature model that recapitulates and integrates this ensemble of pathophysiological processes. Under controlled flow conditions, the model enabled quantitative investigation of how biophysical alterations in hematologic disease collectively lead to microvascular occlusion and thrombosis. Using blood samples from patients with SCD, we investigated how the drug hydroxyurea quantitatively affects microvascular obstruction in SCD, an unresolved issue pivotal to understanding its clinical efficacy in such patients. In addition, we demonstrated that our microsystem can function as an in vitro model of HUS and showed that shear stress influences microvascular thrombosis/obstruction and the efficacy of the drug eptifibatide, which decreases platelet aggregation, in the context of HUS. These experiments establish the versatility and clinical relevance of our microvasculature-on-a-chip model as a biophysical assay of hematologic pathophysiology as well as a drug discovery platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, microfluidic devices (i.e. thrombosis-on-chip devices) are of interest to mimic a range of flows and shear stresses, starting from low (i.e. in veins) to high values (i.e. in arteries) [287–290].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices possess endothelialized lumen that can reliably capture several features of blood vessels such as atherosclerosis (i.e. fatty plaque deposition and formation) and bifurcations (i.e. branches and bends) by changing the channel geometries and flow patterns, ranging from laminar steady flow to pulsatile flow [287–290,295–304].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moake, J. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmra020528 · Cited by 1,221
Self-citationPathogenesis and Treatment of Sickle Cell Disease
Bunn, H. F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371107 · Cited by 1,154
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Vestweber (2008) · doi:10.1161/atvbaha.107.158014 · Cited by 806
Adhesion Mechanisms in Platelet Function
Ruggeri, Z. M., & Mendolicchio, G. L. (2007) · Circulation Research · doi:10.1161/01.res.0000267878.97021.ab · Cited by 755
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Mechanics of Stimulated Neutrophils: Cell Stiffening Induces Retention in Capillaries
Worthen, G. S., Schwab, B., Elson, E. L., & Downey, G. P. (1989) · Science · doi:10.1126/science.2749255 · Cited by 597
Fung, Y. C. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2696-1 · Cited by 466
Shelby, J. P., White, J., Ganesan, K., Rathod, P. K., & Chiu, D. T. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2433968100 · Cited by 433
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
How I use hydroxyurea to treat young patients with sickle cell anemia
Ware, R. E. (2010) · Blood · doi:10.1182/blood-2009-04-146852 · Cited by 396
Self-citationRe-configurable fluid circuits by PDMS elastomer micromachining
Armani, D., Liu, C., & Aluru, N. (1999) · Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291) · doi:10.1109/memsys.1999.746817 · Cited by 382
Hidalgo, A., Chang, J., Jang, J.-E., Peired, A. J., Chiang, E. Y., & Frenette, P. S. (2009) · Nature Medicine · doi:10.1038/nm.1939 · Cited by 358
Barabino, G. A., Platt, M. O., & Kaul, D. K. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105339 · Cited by 311
Analyzing cell mechanics in hematologic diseases with microfluidic biophysical flow cytometry
Rosenbluth, M. J., Lam, W. A., & Fletcher, D. A. (2008) · Lab on a Chip · doi:10.1039/b802931h · Cited by 297
Self-citationCellular signaling and NO production
Michel, T., & Vanhoutte, P. M. (2010) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-009-0765-9 · Cited by 287
Perry, M. A., & Granger, D. N. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115200 · Cited by 250
Brandão, M. M., Fontes, A., Barjas‐Castro, M. L., Barbosa, L. C., Costa, F. F., Cesar, C. L., & Saad, S. T. O. (2003) · European Journal of Haematology · doi:10.1034/j.1600-0609.2003.00027.x · Cited by 250
Nitric oxide donor properties of hydroxyurea in patients with sickle cell disease
Gladwin, M. T., Shelhamer, J. H., Ognibene, F. P., Pease‐Fye, M. E., Nichols, J. S., Link, B., Patel, D. B., Jankowski, M. A., Pannell, L. K., Schechter, A. N., et al. (2002) · British Journal of Haematology · doi:10.1046/j.1365-2141.2002.03274.x · Cited by 234
Macro- and microscale fluid flow systems for endothelial cell biology
Young, E. W. K., & Simmons, C. A. (2010) · Lab Chip · doi:10.1039/b913390a · Cited by 215
Sickle Red Cell–Endothelium Interactions
KAUL, D. K., FINNEGAN, E., & BARABINO, G. A. (2009) · Microcirculation · doi:10.1080/10739680802279394 · Cited by 208
Sickle cell disease and stroke
Verduzco, L. A., & Nathan, D. G. (2009) · Blood · doi:10.1182/blood-2009-05-220921 · Cited by 207
Shiga toxin-associated hemolytic uremic syndrome: pathophysiology of endothelial dysfunction
Zoja, C., Buelli, S., & Morigi, M. (2010) · Pediatric Nephrology · doi:10.1007/s00467-010-1522-1 · Cited by 186
Sickle cell vasoocclusion and rescue in a microfluidic device
Higgins, J. M., Eddington, D. T., Bhatia, S. N., & Mahadevan, L. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707122105 · Cited by 185
A multiparameter analysis of sickle erythrocytes in patients undergoing hydroxyurea therapy
Bridges, K., Barabino, G., Brugnara, C., Cho, M., Christoph, G., Dover, G., Ewenstein, B., Golan, D., Guttmann, C., Hofrichter, J., et al. (1996) · Blood · doi:10.1182/blood.v88.12.4701.bloodjournal88124701 · Cited by 184
Blood viscosity in small tubes: effect of shear rate, aggregation, and sedimentation
Reinke, W., Gaehtgens, P., & Johnson, P. C. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.3.h540 · Cited by 171
A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
Ware, R. E., Eggleston, B., Redding-Lallinger, R., Wang, W. C., Smith-Whitley, K., Daeschner, C., Gee, B., Styles, L. A., Helms, R. W., Kinney, T. R., et al. (2002) · Blood · doi:10.1182/blood.v99.1.10 · Cited by 166
Self-citationBarabino, G., McIntire, L., Eskin, S., Sears, D., & Udden, M. (1987) · Blood · doi:10.1182/blood.v70.1.152.152 · Cited by 165
Nolasco, L. H., Turner, N. A., Bernardo, A., Tao, Z., Cleary, T. G., Dong, J.-F., & Moake, J. L. (2005) · Blood · doi:10.1182/blood-2005-05-2111 · Cited by 161
Self-citationClinical microfluidics for neutrophil genomics and proteomics
Program, T. I. A. T. H. R. T. I. C. R., Kotz, K. T., Xiao, W., Miller-Graziano, C., Qian, W.-J., Russom, A., Warner, E. A., Moldawer, L. L., De, A., Bankey, P. E., et al. (2010) · Nature Medicine · doi:10.1038/nm.2205 · Cited by 161
The polymorphonuclear leucocyte count in childhood haemolytic uraemic syndrome
Walters, M. D. S., Matthei, I. U., Kay, R. W. W., Dillon, M. J., & Barratt, T. M. (1989) · Pediatric Nephrology · doi:10.1007/bf00852893 · Cited by 154
Mohandas, N., & Evans, E. (1985) · Journal of Clinical Investigation · doi:10.1172/jci112144 · Cited by 145
Advances in the use of hydroxyurea
Ware, R. E., & Aygun, B. (2009) · Hematology · doi:10.1182/asheducation-2009.1.62 · Cited by 142
Self-citationSluiter, W., Pietersma, A., Lamers, J. M. J., & Koster, J. F. (1993) · PubMed · Cited by 137
Borenstein, J. T., Tupper, M. M., Mack, P. J., Weinberg, E. J., Khalil, A. S., Hsiao, J. C., & García‐Cardeña, G. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9361-1 · Cited by 122
Sickle Red Cell Microrheology and Sickle Blood Rheology
BALLAS, S. K., & MOHANDAS, N. (2004) · Microcirculation · doi:10.1080/10739680490279410 · Cited by 122
A novel multishear microdevice for studying cell mechanics
Chau, L., Doran, M., & Cooper-White, J. (2009) · Lab on a Chip · doi:10.1039/b823180j · Cited by 117
Morigi, M., Galbusera, M., Binda, E., Imberti, B., Gastoldi, S., Remuzzi, A., Zoja, C., & Remuzzi, G. (2001) · Blood · doi:10.1182/blood.v98.6.1828 · Cited by 102
Microvascular abnormalities in sickle cell disease: a computer-assisted intravital microscopy study
Cheung, A. T. W., Chen, P. C. Y., Larkin, E. C., Duong, P. L., Ramanujam, S., Tablin, F., & Wun, T. (2002) · Blood · doi:10.1182/blood.v99.11.3999 · Cited by 95
Leukocyte Adhesion Molecules on the Vascular Endothelium
Sluiter, W. J., Pietersma, A., Lamers, J. M. J., & Koster, J. F. (1993) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199322004-00006 · Cited by 95
Cytokines in Sickle Cell Disease
Pathare, A., Kindi, S. A., Daar, S., & Dennison, D. (2003) · Hematology · doi:10.1080/10245330310001604719 · Cited by 94
A physiologically realistic in vitro model of microvascular networks
Rosano, J. M., Tousi, N., Scott, R. C., Krynska, B., Rizzo, V., Prabhakarpandian, B., Pant, K., Sundaram, S., & Kiani, M. F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9322-8 · Cited by 83
Lucas, R., Lou, J., Morel, D. R., Ricou, B., Suter, P. M., & Grau, G. E. (1997) · Journal of Leukocyte Biology · doi:10.1002/jlb.61.5.551 · Cited by 74
Mezzano, D., Quiroga, T., & Pereira, J. I. (2009) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0029-1220785 · Cited by 71
Dirnagl, U., Niwa, K., Sixt, G., & Villringer, A. (1994) · Stroke · doi:10.1161/01.str.25.5.1028 · Cited by 70
Macrorheology and adaptive microrheology of endothelial cells subjected to fluid shear stress
Dangaria, J. H., & Butler, P. J. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00193.2007 · Cited by 56
Qiu, W., Kass, D. A., Hu, Q., & Ziegelstein, R. C. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5401 · Cited by 56
Curran, M. P., & Keating, G. M. (2005) · Drugs · doi:10.2165/00003495-200565140-00007 · Cited by 45
Rheologic impairment of sickle RBCs induced by repetitive cycles of deoxygenation-reoxygenation
Nash, G., Johnson, C., & Meiselman, H. (1988) · Blood · doi:10.1182/blood.v72.2.539.539 · Cited by 42
Athanassiou, G., Moutzouri, A. G., Kourakli, A., & Zoumbos, N. C. (2006) · PubMed · Cited by 31
Mathur, A. B., Reichert, W. M., & Truskey, G. A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9288-8 · Cited by 31
Use of directly molded poly(methyl methacrylate) channels for microfluidic applications
Lee, S. H., Kang, D. H., Kim, H. N., & Suh, K. Y. (2010) · Lab on a Chip · doi:10.1039/c0lc00127a · Cited by 27
Ishikawa, M., Sekizuka, E., Oshio, C., Sato, S., Yamaguchi, N., Terao, S., Tsukada, K., Minamitani, H., & Kawase, T. (2002) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(01)00673-6 · Cited by 25
Haemolytic uraemic syndrome: prognostic factors
Green, D. A., Murphy, W. G., & Uttley, W. S. (2000) · Clinical & Laboratory Haematology · doi:10.1046/j.1365-2257.2000.00272.x · Cited by 18
Research works printed but not linked: 2
- Athanassiou, 2006, Clin Hemorheol Microcirc., 35, 291
- Reinke, 1987, Am J Physiol., 253, H540
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
Metadata
- Authors
- Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Lam, Wilbur A.
- Venue
- Journal of Clinical Investigation
- Published
- 2012-01-03
- Volume
- 122
- Issue
- 1
- Pages
- 408-418
- ISSN
- 0021-9738 (ISSN-L)
- PMC
- PMC3248292
- OpenAlex
- W2134766290
- Cited by
- 297
- References
- 58
- Citations by year
- 2026: 13 · 2025: 18 · 2024: 11 · 2023: 23 · 2022: 19 · 2021: 25 · 2020: 25 · 2019: 19 · 2018: 20 · 2017: 33 · 2016: 21 · 2015: 22 · 2014: 26 · 2013: 12 · 2012: 9
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Investigation (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (CAREER)
- Emory University
- Children's Healthcare of Atlanta
- National Institutes of Health (NIH-R01)
- U.S. Public Health Service
- University of California, San Francisco
- National Heart, Lung, and Blood Institute (K08HL093360, U54HL112309)
- National Eye Institute (PN2EY018244)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
- Keywords
- microvascular occlusion, thrombosis, sickle cell disease, hemolytic uremic syndrome, hydroxyurea, eptifibatide, shear stress, platelet aggregation, in vitro disease model, drug discovery
- MeSH terms
- Eptifibatide, Anemia, Sickle Cell, Hematologic Diseases, Hemolytic-Uremic Syndrome, Humans, Hydroxyurea, Microscopy, Fluorescence, Models, Cardiovascular, Peptides, Platelet Aggregation Inhibitors, Thrombosis, Hemorheology, Microfluidic Analytical Techniques, Microvessels, Human Umbilical Vein Endothelial Cells, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.