In vitro modeling of the microvascular occlusion and thrombosis that occur in hematologic diseases using microfluidic technology
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In hematologic diseases, such as sickle cell disease (SCD) and hemolytic uremic syndrome (HUS), pathological biophysical interactions among blood cells, endothelial cells, and soluble factors lead to microvascular occlusion and thrombosis. Here, we report an in vitro "endothelialized" microfluidic microvasculature model that recapitulates and integrates this ensemble of pathophysiological processes. Under controlled flow conditions, the model enabled quantitative investigation of how biophysical alterations in hematologic disease collectively lead to microvascular occlusion and thrombosis. Using blood samples from patients with SCD, we investigated how the drug hydroxyurea quantitatively affects microvascular obstruction in SCD, an unresolved issue pivotal to understanding its clinical efficacy in such patients. In addition, we demonstrated that our microsystem can function as an in vitro model of HUS and showed that shear stress influences microvascular thrombosis/obstruction and the efficacy of the drug eptifibatide, which decreases platelet aggregation, in the context of HUS. These experiments establish the versatility and clinical relevance of our microvasculature-on-a-chip model as a biophysical assay of hematologic pathophysiology as well as a drug discovery platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, microfluidic devices (i.e. thrombosis-on-chip devices) are of interest to mimic a range of flows and shear stresses, starting from low (i.e. in veins) to high values (i.e. in arteries) [287–290].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices possess endothelialized lumen that can reliably capture several features of blood vessels such as atherosclerosis (i.e. fatty plaque deposition and formation) and bifurcations (i.e. branches and bends) by changing the channel geometries and flow patterns, ranging from laminar steady flow to pulsatile flow [287–290,295–304].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [289]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moake, J. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmra020528 · Cited by 1,221
Self-citationPathogenesis and Treatment of Sickle Cell Disease
Bunn, H. F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371107 · Cited by 1,154
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
The microcirculation and inflammation: modulation of leukocyte-endothelial cell adhesion
Granger, D. N., & Kubes, P. (1994) · Journal of Leukocyte Biology · doi:10.1002/jlb.55.5.662 · Cited by 849
Vestweber (2008) · doi:10.1161/atvbaha.107.158014 · Cited by 806
Adhesion Mechanisms in Platelet Function
Ruggeri, Z. M., & Mendolicchio, G. L. (2007) · Circulation Research · doi:10.1161/01.res.0000267878.97021.ab · Cited by 755
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Mechanics of Stimulated Neutrophils: Cell Stiffening Induces Retention in Capillaries
Worthen, G. S., Schwab, B., Elson, E. L., & Downey, G. P. (1989) · Science · doi:10.1126/science.2749255 · Cited by 597
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
Personalised organs-on-chips: functional testing for precision medicine
van den Berg, A., Mummery, C. L., Passier, R., & van der Meer, A. D. (2019) · Lab on a Chip · doi:10.1039/c8lc00827b · Cited by 270
3D printed drug delivery and testing systems — a passing fad or the future?
Lim, S. H., Kathuria, H., Tan, J. J. Y., & Kang, L. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.05.006 · Cited by 252
Identification of platelet function defects by multi-parameter assessment of thrombus formation
de Witt, S. M., Swieringa, F., Cavill, R., Lamers, M. M. E., van Kruchten, R., Mastenbroek, T., Baaten, C., Coort, S., Pugh, N., Schulz, A., et al. (2014) · Nature Communications · doi:10.1038/ncomms5257 · Cited by 239
Bioprinted thrombosis-on-a-chip
Zhang, Y. S., Davoudi, F., Walch, P., Manbachi, A., Luo, X., Dell'Erba, V., Miri, A. K., Albadawi, H., Arneri, A., Li, X., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00380j · Cited by 227
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Ultrasoft microgels displaying emergent platelet-like behaviours
Brown, A. C., Stabenfeldt, S. E., Ahn, B., Hannan, R. T., Dhada, K. S., Herman, E. S., Stefanelli, V., Guzzetta, N., Alexeev, A., Lam, W. A., et al. (2014) · Nature Materials · doi:10.1038/nmat4066 · Cited by 220
Self-citationAdvances in predictive in vitro models of drug-induced nephrotoxicity
Soo, J. Y.-C., Jansen, J., Masereeuw, R., & Little, M. H. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0003-9 · Cited by 191
Probing nanoparticle translocation across the permeable endothelium in experimental atherosclerosis
Kim, Y., Lobatto, M. E., Kawahara, T., Lee Chung, B., Mieszawska, A. J., Sanchez-Gaytan, B. L., Fay, F., Senders, M. L., Calcagno, C., Becraft, J., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1322725111 · Cited by 189
Qiu, Y., Ahn, B., Sakurai, Y., Hansen, C. E., Tran, R., Mimche, P. N., Mannino, R. G., Ciciliano, J. C., Lamb, T. J., Joiner, C. H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0224-z · Cited by 187
Self-citationHigh-Throughput Methods in the Discovery and Study of Biomaterials and Materiobiology
Yang, L., Pijuan-Galito, S., Rho, H. S., Vasilevich, A. S., Eren, A. D., Ge, L., Habibović, P., Alexander, M. R., de Boer, J., Carlier, A., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00752 · Cited by 180
Platelet interaction with activated endothelium: mechanistic insights from microfluidics
Coenen, D. M., Mastenbroek, T. G., & Cosemans, J. M. E. M. (2017) · Blood · doi:10.1182/blood-2017-04-780825 · Cited by 180
Magnetic forces enable controlled drug delivery by disrupting endothelial cell-cell junctions
Qiu, Y., Tong, S., Zhang, L., Sakurai, Y., Myers, D. R., Hong, L., Lam, W. A., & Bao, G. (2017) · Nature Communications · doi:10.1038/ncomms15594 · Cited by 173
“3a,b) 36,37 .”
Self-citationThe Importance of Mechanical Forces for in vitro Endothelial Cell Biology
Gordon, E., Schimmel, L., & Frye, M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00684 · Cited by 171
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Vasculature-On-A-Chip for In Vitro Disease Models
Kim, S., Kim, W., Lim, S., & Jeon, J. (2017) · Bioengineering · doi:10.3390/bioengineering4010008 · Cited by 157
Advances in three-dimensional rapid prototyping of microfluidic devices for biological applications
O’Neill, P., Azouz, A. B., Vázquez, M., Liu, J., Marczak, S. P., Slouka, Z., Chang, H., Diamond, D., & Brabazon, D. (2014) · Biomicrofluidics · doi:10.1063/1.4898632 · Cited by 174
Sosale, N. G., Rouhiparkouhi, T., Bradshaw, A. M., Dimova, R., Lipowsky, R., & Discher, D. E. (2015) · Blood · doi:10.1182/blood-2014-06-585299 · Cited by 155
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
“Over the last decade, microfluidic devices that contain hollow channels lined by living endothelium have been exposed to flowing blood to study the basic science of thrombosis in vitro (Colace et al. 2013; Neeves et al. 2013; Tsai et al. 2012; Zheng et al. 2012).”
BackgroundChinnadurai, R., Garcia, M. A., Sakurai, Y., Lam, W. A., Kirk, A. D., Galipeau, J., & Copland, I. B. (2014) · Stem Cell Reports · doi:10.1016/j.stemcr.2014.05.003 · Cited by 139
“The design and fabrication of three-dimensional in vitro ‘‘endothelialized’’ microvasculature models were described previously (Tsai et al., 2012).”
MethodSelf-citationBarrile, R., van der Meer, A. D., Park, H., Fraser, J. P., Simic, D., Teng, F., Conegliano, D., Nguyen, J., Jain, A., Zhou, M., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1054 · Cited by 138
Modeling Ischemic Stroke In Vitro: Status Quo and Future Perspectives
Holloway, P. M., & Gavins, F. N. E. (2016) · Stroke · doi:10.1161/strokeaha.115.011932 · Cited by 157
Microfluidics and Coagulation Biology
Colace, T. V., Tormoen, G. W., McCarty, O. J. T., & Diamond, S. L. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152406 · Cited by 124
“(27) have had success culturing endothelial cells on fibronectincoated surfaces in microfluidic chambers (Figure 3g).”
BackgroundKinetics of sickle cell biorheology and implications for painful vasoocclusive crisis
Du, E., Diez-Silva, M., Kato, G. J., Dao, M., & Suresh, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424111112 · Cited by 129
A Biophysical Indicator of Vaso-occlusive Risk in Sickle Cell Disease
Wood, D. K., Soriano, A., Mahadevan, L., Higgins, J. M., & Bhatia, S. N. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3002738 · Cited by 120
“This system could also be used to quantitatively probe the role of other cell types, such as vascular endothelium, that are implicated in the vaso-occlusive process (32).”
Xiao, Y., Kim, D., Dura, B., Zhang, K., Yan, R., Li, H., Han, E., Ip, J., Zou, P., Liu, J., et al. (2019) · Advanced Science · doi:10.1002/advs.201801531 · Cited by 115
Heterogeneous Red Blood Cell Adhesion and Deformability in Sickle Cell Disease
Alapan, Y., Little, J. A., & Gurkan, U. A. (2014) · Scientific Reports · doi:10.1038/srep07173 · Cited by 116
Dobó, J., Kocsis, A., Farkas, B., Demeter, F., Cervenak, L., & Gál, P. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25031566 · Cited by 120
“Further underscoring the relevance of MASP-1 in inflammation, it was found to strongly synergize with other commonly recognized proinflammatory mediators (LPS, histamine, IFN γ , and bradykinin) [124] and with hypoxia (an unpublished observation) to enhance the inflammatory response of HUVECS.”
BackgroundMicrofluidics to Mimic Blood Flow in Health and Disease
Sebastian, B., & Dittrich, P. S. (2017) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010816-060246 · Cited by 117
Organ-on-a-chip technology: a novel approach to investigate cardiovascular diseases
Paloschi, V., Sabater‐Lleal, M., Middelkamp, H. H. T., Vivas, A., Johansson, S., van der Meer, A. D., Tenje, M., & Mäegdefessel, L. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab088 · Cited by 116
“For example, Tsai and collaborators used a vessel-on-chip device to perfuse blood samples from patients with sickle cell disease and test the effect of certain drugs in microvascular occlusion and thrombosis.(93) Another study by Barrile et al.”
MethodA microengineered vascularized bleeding model that integrates the principal components of hemostasis
Sakurai, Y., Hardy, E. T., Ahn, B., Tran, R., Fay, M. E., Ciciliano, J. C., Mannino, R. G., Myers, D. R., Qiu, Y., Carden, M. A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02990-x · Cited by 110
Self-citationPicot, J., Ndour, P. A., Lefevre, S. D., Nemer, W. E., Tawfik, H., Galimand, J., Costa, L. M. D., Ribeil, J., de Montalembert, M., Brousse, V. A. M., et al. (2015) · American Journal of Hematology · doi:10.1002/ajh.23941 · Cited by 101
Mathur, T., Singh, K. A., Pandian, N. K. R., Tsai, S., Hein, T. W., Gaharwar, A. K., Flanagan, J. M., & Jain, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00469f · Cited by 107
The biophysics and mechanics of blood from a materials perspective
Qiu, Y., Myers, D. R., & Lam, W. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0099-y · Cited by 109
Self-citationMicrofluidic Thrombosis under Multiple Shear Rates and Antiplatelet Therapy Doses
Li, M., Hotaling, N. A., Ku, D. N., & Forest, C. R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0082493 · Cited by 93
Tsvirkun, D., Grichine, A., Duperray, A., Misbah, C., & Bureau, L. (2017) · Scientific Reports · doi:10.1038/srep45036 · Cited by 107
“…have been shown (i) to line the entire lumen of the channels 21,23,27,29 , (ii) to properly express VE-cadherins and form tight cell/cell junctions 27,29 , which ensures good barrier functions to the endothelium 21 , and (iii) to display typical surface adhesion molecules such as ICAM-1 22 and…”
InfluentialOrgan-on-a-chip and the kidney
Kim, S., & Takayama, S. (2015) · Kidney Research and Clinical Practice · doi:10.1016/j.krcp.2015.08.001 · Cited by 106
“So far, several individual organ-on-chips have been developed, including gut-on-a-chip [6], lung-on-a-chip [7], blood vesselon-a-chip [8], cancer-on-a-chip [9], bone marrow-on-a-chip [10], and kidney-on-a-chip [11].”
Microfluidic-based vascularized microphysiological systems
Lee, S., Ko, J., Park, D., Lee, S.-R., Chung, M., Lee, Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00285a · Cited by 91
Ciciliano, J. C., Sakurai, Y., Myers, D. R., Fay, M. E., Hechler, B., Meeks, S. L., Li, R., Dixon, J. B., Lyon, L. A., Gachet, C., et al. (2015) · Blood · doi:10.1182/blood-2015-02-628594 · Cited by 89
“When appropriate, channels were endothelialized as previously described.(15) To study whole blood, RBCs were diluted in PRP to 12.”
MethodSelf-citationAdvances in Platelet Function Testing—Light Transmission Aggregometry and Beyond
Blanc, J. L., Mullier, F., Vayne, C., & Lordkipanidzé, M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9082636 · Cited by 84
“Microfluidic devices that incorporate endothelial cells could be useful in assessing platelet function in hematologic diseases such as sickle cell disease and hemolytic uremic syndrome [73].”
BackgroundIntegrating the core professional values of nursing: a profession, not just a career.
Shaw, H. K., & Degazon, C. E. (2008) · PubMed · Cited by 84
Recent lab‐on‐chip developments for novel drug discovery
Khalid, N., Kobayashi, I., & Nakajima, M. (2017) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1381 · Cited by 83
Characterizing asthma from a drop of blood using neutrophil chemotaxis
Sackmann, E. K., Berthier, E., Schwantes, E. A., Fichtinger, P. S., Evans, M. D., Dziadzio, L., Huttenlocher, A., Mathur, S. K., & Beebe, D. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1324043111 · Cited by 81
Complex 3D microfluidic architectures formed by mechanically guided compressive buckling
Luan, H., Zhang, Q., Liu, T., Wang, X. S., Zhao, S., Wang, H., Yao, S., Xue, Y., Kwak, J. W., Bai, W., et al. (2021) · Science Advances · doi:10.1126/sciadv.abj3686 · Cited by 84
“Traditional 2D microfluidic technologies (3, 13) serve important roles in artificial vascular networks (9, 11, 14) and various types of biomedical microsystems (15–17).”
BackgroundKuddannaya, S., Bao, J., & Zhang, Y. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09032 · Cited by 87
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
Regenerative and durable small-diameter graft as an arterial conduit
Elliott, M. B., Ginn, B. P., Fukunishi, T., Bedja, D., Suresh, A., Chen, T., Inoue, T., Dietz, H. C., Santhanam, L., Mao, H., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1905966116 · Cited by 81
“Vascular shear stress can range between 1 and 70 dyn/cm(2) depending on the size and type of vessel (48), with moderate levels (5–10 dyn/cm(2)) being prevalent in arteries and high levels (>10 dyn/cm(2)) being present in capillaries and small arterioles (49, 50).”
BackgroundZhao, Y. C., Vatankhah, P., Goh, T., Michelis, R., Kyanian, K., Zhang, Y., Li, Z., & Ju, L. A. (2021) · Scientific Reports · doi:10.1038/s41598-021-86310-2 · Cited by 77
Nguyen, V. P., Li, Y., Qian, W. P., Liu, B., Tian, C., Zhang, W., Huang, Z., Ponduri, A., Tarnowski, M., Wang, X., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-42324-5 · Cited by 74
Aman, J., Weijers, E. M., Amerongen, G. P. V. N., Malik, A. B., & van Hinsbergh, V. W. M. (2016) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00393.2015 · Cited by 79
Microfluidic technology as an emerging clinical tool to evaluate thrombosis and hemostasis
Branchford, B. R., Ng, C. J., Neeves, K. B., & Paola, J. D. (2015) · Thrombosis Research · doi:10.1016/j.thromres.2015.05.012 · Cited by 77
“The future of microfluidic assays likely will include endothelialized microvasculature models [30,59,60] and microfluidic models of vessel stenosis [27,28,61,62].”
BackgroundMethodChen, H., Yu, Z., Bai, S., Lu, H., Xu, D. L., Chen, C., Li, J., & Zhu, Y. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.023 · Cited by 86
Emerging science of hydroxyurea therapy for pediatric sickle cell disease
Green, N., & Barral, S. (2013) · Pediatric Research · doi:10.1038/pr.2013.227 · Cited by 81
“Decreased expression of RBCs, white blood cells, and endothelial integrins and other adhesion molecules probably improves microvascular blood flow and reduces proinflammatory cell– cell interactions (43,44).”
BackgroundLam, R. H. W., Weng, S., Lu, W. D., & Fu, J. (2012) · Integrative Biology · doi:10.1039/c2ib20134h · Cited by 74
Emerging point-of-care technologies for sickle cell disease screening and monitoring
Alapan, Y., Fraiwan, A., Kucukal, E., Hasan, M. N., Ung, R., Kim, M., Odame, I., Little, J. A., & Gurkan, U. A. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1254038 · Cited by 71
“developed a microfluidic platform with an inner surface coated by a confluent monolayer of endothelial cells for modeling vascular occlusion and thrombosis in hematologic diseases, such as SCD (Figure 3(a)) [244].”
BackgroundMethodA Robust Method for Perfusable Microvascular Network Formation In Vitro
Wan, Z., Zhong, A. X., Zhang, S., Pavlou, G., Coughlin, M. F., Shelton, S. E., Nguyen, H. T., Lorch, J. H., Barbie, D. A., & Kamm, R. D. (2022) · Small Methods · doi:10.1002/smtd.202200143 · Cited by 64
Recent Developments in 3D Printing of Droplet-Based Microfluidics
Aladese, A. D., & Jeong, H. (2021) · BioChip Journal · doi:10.1007/s13206-021-00032-1 · Cited by 65
Molecular Hemocompatibility of Graphene Oxide and Its Implication for Antithrombotic Applications
Kenry, K., Loh, K. P., & Lim, C. T. (2015) · Small · doi:10.1002/smll.201500841 · Cited by 64
Extracellular fluid tonicity impacts sickle red blood cell deformability and adhesion
Carden, M. A., Fay, M. E., Lu, X., Mannino, R. G., Sakurai, Y., Ciciliano, J. C., Hansen, C. E., Chonat, S., Joiner, C. H., Wood, D. K., et al. (2017) · Blood · doi:10.1182/blood-2017-04-780635 · Cited by 63
Self-citationCell-microenvironment interactions and architectures in microvascular systems
Bersini, S., Yazdi, I. K., Talò, G., Shin, S. R., Moretti, M., & Khademhosseini, A. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.07.002 · Cited by 58
“, 2013, Zhang, Peticone, 2013), develop vascular disease models (Tsai et al., 2012) and analyze mass transfer and diffusion phenomena within tissue constructs (Baker et al.”
Neeves, K. B., Onasoga, A. A., & Wufsus, A. R. (2013) · Current Opinion in Hematology · doi:10.1097/moh.0b013e3283642186 · Cited by 59
“(c) Endothelialized microvascular mimic for measuring thrombotic occlusions [44].”
BackgroundA Microfluidic Model of Hemostasis Sensitive to Platelet Function and Coagulation
Schoeman, R. M., Rana, K., Danes, N., Lehmann, M., Paola, J. A. D., Fogelson, A. L., Leiderman, K., & Neeves, K. B. (2016) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-016-0469-0 · Cited by 69
Thrombosis-on-a-chip: prospective impact of microphysiological models of vascular thrombosis
Pandian, N. K. R., Mannino, R. G., Lam, W. A., & Jain, A. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.12.001 · Cited by 56
Self-citationFranco, C. A., & Gerhardt, H. (2012) · Nature · doi:10.1038/488465a · Cited by 64
Rosellini, E., & Cascone, M. G. (2023) · Biomimetics · doi:10.3390/biomimetics8010074 · Cited by 59
“For the latter, in vitro models, that replicate organ functions and diseases on a microchip [9,10] in order to test new drugs, have been developed.”
BackgroundMonitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
“PDMS microfluidics using multiple parallel microchannels, lined with endothelial cells, could also model the pathophysiological processes of sickle cell disease and hemolytic uremic syndrome under blood flow conditions [47].”
BackgroundPandian, N. K. R., Walther, B. K., Suresh, R., Cooke, J. P., & Jain, A. (2020) · Small · doi:10.1002/smll.202003401 · Cited by 60
Doherty, E. L., Aw, W. Y., Hickey, A. J., & Polacheck, W. J. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.624435 · Cited by 62
“coated ∼30μm branching PDMS channels with fibronectin as a substrate for endothelial cells to enable perfusion of human blood to assess the efficacy of vascular occlusion treatment in sickle cell disease and hemolytic uremic syndrome (Figure 2; Tsai et al., 2011).”
MethodKucukal, E., Ilich, A., Key, N. S., Little, J. A., & Gurkan, U. A. (2018) · American Journal of Hematology · doi:10.1002/ajh.25159 · Cited by 56
“1 mm(2)).(17,18,37) Having a large interrogation surface area significantly improves our ability to capture rare adhesive events for clinical samples with low adhesion potential.”
BackgroundMethodSimitian, G. S., Virumbrales-Muñoz, M., Sánchez‐de‐Diego, C., Beebe, D. J., & Kosoff, D. (2022) · Lab on a Chip · doi:10.1039/d2lc00352j · Cited by 56
The recent development and applications of fluidic channels by 3D printing
Zhou, Y. (2017) · Journal of Biomedical Science · doi:10.1186/s12929-017-0384-2 · Cited by 58
Endothelialized Microfluidics for Studying Microvascular Interactions in Hematologic Diseases
Myers, D. R., Sakurai, Y., Tran, R., Ahn, B., Hardy, E. T., Mannino, R. G., Kita, A., Tsai, M., & Lam, W. A. (2012) · Journal of Visualized Experiments · doi:10.3791/3958 · Cited by 51
Self-citationFluid flow to mimic organ function in 3D in vitro models
Juste-Lanas, Y., Hervás-Raluy, S., García‐Aznar, J. M., & González‐Loyola, A. (2023) · APL Bioengineering · doi:10.1063/5.0146000 · Cited by 57
Berry, J., Peaudecerf, F. J., Masters, N. A., Neeves, K. B., Goldstein, R. E., & Harper, M. T. (2021) · Lab on a Chip · doi:10.1039/d1lc00347j · Cited by 55
Bone‐on‐a‐Chip: A Microscale 3D Biomimetic Model to Study Bone Regeneration
Galván-Chacón, V., Zampouka, A., Hesse, B., Bohner, M., Habibović, P., & Barata, D. B. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202101467 · Cited by 53
Cushman, M., Barnes, G. D., Creager, M. A., Diaz, J. A., Henke, P. K., Machlus, K. R., Nieman, M. T., & Wolberg, A. S. (2020) · Circulation · doi:10.1161/cir.0000000000000818 · Cited by 47
Liu, Y., Gill, E., & Huang, Y. Y. S. (2017) · Future Science OA · doi:10.4155/fsoa-2016-0084 · Cited by 51
Microfluidics for Cancer Nanomedicine: From Fabrication to Evaluation
Zhang, H., Zhu, Y., & Shen, Y. (2018) · Small · doi:10.1002/smll.201800360 · Cited by 49
Lizarralde-Iragorri, M. A., Hoss, S. E., Brousse, V. A. M., Lefevre, S. D., Dussiot, M., Xu, T., Ferreira, A. R., Lamarre, Y., Pinto, A. C. S., Kashima, S. H., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00637g · Cited by 51
Biomimetic channel modeling local vascular dynamics of pro-inflammatory endothelial changes
Thomas, A., Daniel Ou-Yang, H., Lowe-Krentz, L., Muzykantov, V. R., & Liu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4936672 · Cited by 46
Dynamics of Blood Flow and Thrombus Formation in a Multi-Bypass Microfluidic Ladder Network
Zilberman‐Rudenko, J., Sylman, J. L., Lakshmanan, H. H. S., McCarty, O. J. T., & Maddala, J. (2016) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-016-0470-7 · Cited by 49
Véliz, D. S., Lin, K., & Sahlgren, C. (2023) · Smart Medicine · doi:10.1002/smmd.20220030 · Cited by 48
Myers, D. R., & Lam, W. A. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-091520-025358 · Cited by 51
“Using appropriate controls is a must (54).”
BackgroundInfluentialSelf-citationMicrofluidic approaches to the study of angiogenesis and the microcirculation
Akbari, E., Spychalski, G. B., & Song, J. W. (2017) · Microcirculation · doi:10.1111/micc.12363 · Cited by 54
“Moreover, the design and fabrication process of PDMS soft lithography enables scale-to-scale recapitulation of the topology of hierarchical branching vessels for studying hemodynamic parameters that reflect microvascular function, such as red blood cell behaviors under the influence of flow [37], hematocrit [32], and…”
BackgroundInflammatory targets of therapy in sickle cell disease
Owusu-Ansah, A. T., Ihunnah, C. A., Walker, A. L., & Ofori-Acquah, S. F. (2015) · Translational research · doi:10.1016/j.trsl.2015.07.001 · Cited by 52
In vitro fluidic systems: Applying shear stress on endothelial cells
Meng, F., Cheng, H., Qian, J., Dai, X., Huang, Y., & Fan, Y. (2022) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2022.100143 · Cited by 58
Bioengineering Methods for Analysis of Cells In Vitro
Underhill, G. H., Galie, P. A., Chen, C. S., & Bhatia, S. N. (2012) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-101011-155709 · Cited by 48
“…microfluidic devices containing endothelial cells have built on the extensive work using parallel-plate flow chambers (Chiu et al. 2009) to demonstrate the effects of distinct shear regimes on endothelial cell stimulation and thrombosis (Chin et al. 2011, Tsai et al. 2012, Wang et al. 2011a).”
BackgroundMicrovascular bioengineering: a focus on pericytes
Zhao, H., & Chappell, J. C. (2019) · Journal of Biological Engineering · doi:10.1186/s13036-019-0158-3 · Cited by 49
“Bioengineered microvascular fluidics platforms offer tools to better understand the microcirculation during formation of microthrombi and acute pressure changes that might lead to microvessel rupture [153], the risk for which may vary according to pericyte investment.”
BackgroundIn vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Effects of storage‐aged red blood cell transfusions on endothelial function in hospitalized patients
Neuman, R., Hayek, S. S., Rahman, A. M., Poole, J. C., Menon, V., Sher, S., Newman, J. L., Karatela, S., Polhemus, D. J., Lefer, D. J., et al. (2014) · Transfusion · doi:10.1111/trf.12919 · Cited by 46
“Variable All patients (n = 43) Recipients of saRBCs (>21 days; n = 25) Recipients of fresh RBCs (<14 days; n = 18) Age (years) 59 ± 13 58 ± 12 60 ± 15 Male 24 (55) 13 (52) 11 (58) Race White 23 (54) 15 (63) 8 (42) Black 17 (40) 7 (29) 10 (53) Blood group A– 1 (2) 1 (4) 0 A+ 12 (27) 5 (20) 7 (36) B– 1 (2) 1 (4) 0 B+ 7…”
Thrombosis Models: An Overview of Common In Vivo and In Vitro Models of Thrombosis
Ayyoub, S., Orriols, R., Oliver, E., & Tura-Ceide, O. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032569 · Cited by 47
“Endothelialized microfluidic device A bioassay for hematological disorders and evaluating drug efficacy [32]”
BackgroundMethodInfluentialDevice-Based In Vitro Techniques for Mechanical Stimulation of Vascular Cells: A Review
Davis, C. A., Zambrano, S., Anumolu, P., Allen, A. C. B., Sonoqui, L., & Moreno, M. R. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029016 · Cited by 57
A standalone perfusion platform for drug testing and target validation in micro-vessel networks
Zhang, B., Peticone, C., Murthy, S. K., & Radisic, M. (2013) · Biomicrofluidics · doi:10.1063/1.4818837 · Cited by 38
Metadata
- Authors
- Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Lam, Wilbur A.
- Venue
- Journal of Clinical Investigation
- Published
- 2012-01-03
- Volume
- 122
- Issue
- 1
- Pages
- 408-418
- ISSN
- 0021-9738 (ISSN-L)
- PMC
- PMC3248292
- OpenAlex
- W2134766290
- Cited by
- 297
- References
- 58
- Citations by year
- 2026: 13 · 2025: 18 · 2024: 11 · 2023: 23 · 2022: 19 · 2021: 25 · 2020: 25 · 2019: 19 · 2018: 20 · 2017: 33 · 2016: 21 · 2015: 22 · 2014: 26 · 2013: 12 · 2012: 9
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Investigation (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (CAREER)
- Emory University
- Children's Healthcare of Atlanta
- National Institutes of Health (NIH-R01)
- U.S. Public Health Service
- University of California, San Francisco
- National Heart, Lung, and Blood Institute (K08HL093360, U54HL112309)
- National Eye Institute (PN2EY018244)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Genetics (clinical) › Hemoglobinopathies and Related Disorders
- Keywords
- microvascular occlusion, thrombosis, sickle cell disease, hemolytic uremic syndrome, hydroxyurea, eptifibatide, shear stress, platelet aggregation, in vitro disease model, drug discovery
- MeSH terms
- Eptifibatide, Anemia, Sickle Cell, Hematologic Diseases, Hemolytic-Uremic Syndrome, Humans, Hydroxyurea, Microscopy, Fluorescence, Models, Cardiovascular, Peptides, Platelet Aggregation Inhibitors, Thrombosis, Hemorheology, Microfluidic Analytical Techniques, Microvessels, Human Umbilical Vein Endothelial Cells, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.