In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Objectives: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. Methods: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0° start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. Results: The group mean array insertion depth was 477° (range, 286° to 655°). The word scores were negatively correlated (r = −0.59; p = .028) with the number of electrodes in the scala vestibuli. Conclusions: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A cochlear frequency-position function for several species—29 years later
Greenwood, D. D. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399052 · Cited by 1,890
Ann Otol Rhinol Laryngol [Suppl].
Cw, C. (1978) · PubMed · Cited by 1,313
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
VOIE, A. H., BURNS, D. H., & SPELMAN, F. A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03346.x · Cited by 477
Self-citationCombining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes
Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006) · Audiology and Neurotology · doi:10.1159/000095611 · Cited by 376
Risk of Bacterial Meningitis in Children with Cochlear Implants
Reefhuis, J., Honein, M. A., Whitney, C. G., Chamany, S., Mann, E. A., Biernath, K. R., Broder, K., Manning, S., Avashia, S., Victor, M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031101 · Cited by 368
Multisection CT: Scanning Techniques and Clinical Applications
Rydberg, J., Buckwalter, K. A., Caldemeyer, K. S., Phillips, M. D., Conces, D. J., Aisen, A. M., Persohn, S. A., & Kopecky, K. K. (2000) · RadioGraphics · doi:10.1148/radiographics.20.6.g00nv071787 · Cited by 363
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Self-citationImpact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
Automatic Segmentation of Intracochlear Anatomy in Conventional CT
Noble, J. H., Labadie, R. F., Majdani, O., & Dawant, B. M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160262 · Cited by 168
“manually aligned with the image to identify electrode position [1], [23].”
MethodClinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
Noble, J. H., Gifford, R. H., Hedley-Williams, A. J., Dawant, B. M., & Labadie, R. F. (2014) · Audiology and Neurotology · doi:10.1159/000365273 · Cited by 162
Liebau, A., Pogorzelski, O., Salt, A. N., & Plontke, S. K. (2017) · Otology & Neurotology · doi:10.1097/mao.0000000000001254 · Cited by 54
Metadata
- Authors
- Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 116
- Issue
- 4
- Pages
- 2-24
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2013506837
- Cited by
- 243
- References
- 40
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.