In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Objectives: A new technique for determining the position of each electrode in the cochlea is described and applied to spiral computed tomography data from 15 patients implanted with Advanced Bionics HiFocus I, Ij, or Helix arrays. Methods: ANALYZE imaging software was used to register 3-dimensional image volumes from patients' preoperative and postoperative scans and from a single body donor whose unimplanted ears were scanned clinically, with micro computed tomography and with orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy. By use of this registration, we compared the atlas of OPFOS images of soft tissue within the body donor's cochlea with the bone and fluid/ tissue boundary available in patient scan data to choose the midmodiolar axis position and judge the electrode position in the scala tympani or scala vestibuli, including the distance to the medial and lateral scalar walls. The angular rotation 0° start point is a line joining the midmodiolar axis and the middle of the cochlear canal entry from the vestibule. Results: The group mean array insertion depth was 477° (range, 286° to 655°). The word scores were negatively correlated (r = −0.59; p = .028) with the number of electrodes in the scala vestibuli. Conclusions: Although the individual variability in all measures was large, repeated patterns of suboptimal electrode placement were observed across subjects, underscoring the applicability of this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A cochlear frequency-position function for several species—29 years later
Greenwood, D. D. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399052 · Cited by 1,890
Ann Otol Rhinol Laryngol [Suppl].
Cw, C. (1978) · PubMed · Cited by 1,313
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
VOIE, A. H., BURNS, D. H., & SPELMAN, F. A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03346.x · Cited by 477
Self-citationCombining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes
Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006) · Audiology and Neurotology · doi:10.1159/000095611 · Cited by 376
Risk of Bacterial Meningitis in Children with Cochlear Implants
Reefhuis, J., Honein, M. A., Whitney, C. G., Chamany, S., Mann, E. A., Biernath, K. R., Broder, K., Manning, S., Avashia, S., Victor, M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031101 · Cited by 368
Multisection CT: Scanning Techniques and Clinical Applications
Rydberg, J., Buckwalter, K. A., Caldemeyer, K. S., Phillips, M. D., Conces, D. J., Aisen, A. M., Persohn, S. A., & Kopecky, K. K. (2000) · RadioGraphics · doi:10.1148/radiographics.20.6.g00nv071787 · Cited by 363
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
NADOLJR, J. (1997) · Otolaryngology - Head and Neck Surgery · doi:10.1016/s0194-5998(97)70178-5 · Cited by 359
Conservation of low-frequency hearing in cochlear implantation
Kiefer, J., Gstoettner, W. K., Baumgartner, W., Pok, S. M., Tillein, J., Ye, Q., & Ilberg, C. V. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480310000755a · Cited by 309
Hearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277
Skinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 223
Self-citationHISTOPATHOLOGY OF PROFOUND SENSORINEURAL DEAFNESSa
Hinojosa, R., & Marion, M. S. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31662.x · Cited by 174
Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration
Bierer, J. A., & Middlebrooks, J. C. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00212.2001 · Cited by 172
The biomedical imaging resource at Mayo Clinic
Robb, R. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952724 · Cited by 165
Quality Control after Cochlear Implant Surgery by Means of Rotational Tomography
Aschendorff, A., Kubalek, R., Turowski, B., Zanella, F. E., Hochmuth, A., Schumacher, M. C., Klenzner, T., & Laszig, R. (2005) · Otology & Neurotology · doi:10.1097/00129492-200501000-00007 · Cited by 155
Snyder, R. L., Bierer, J. A., & Middlebrooks, J. C. (2004) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-004-4026-5 · Cited by 154
Fu, Q., Shannon, R. V., & Galvin, J. J. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1502901 · Cited by 149
Cohen, L. T., Xu, J. Y., Xu, S. A., et al. (1996) · PubMed · Cited by 148
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Roland, J. T., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.006 · Cited by 135
Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
Shepherd, R. K., Pyman, B. C., Clark, G. M., & Webb, R. L. (1985) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948509400112 · Cited by 128
Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual Hearing
Boëx, C., Baud, L., Cosendai, G., Sigrist, A., Kós, M.-I., & Pelizzone, M. (2006) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-005-0027-2 · Cited by 120
Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112
Facial nerve stimulation after Nucleus 22-channel cochlear implantation.
Kelsall, D. C., Shallop, J. K., Brammeier, T. G., & Prenger, E. C. (1997) · PubMed · Cited by 109
Correlative study of sensory cell density and cochlear length in humans
Úlehlová, L., Voldrich, L., & Janisch, R. (1987) · Hearing Research · doi:10.1016/0378-5955(87)90045-1 · Cited by 107
Cochlear Implant Deep Electrode Insertion: Extent of Insertional Trauma
Gstoettner, W. K., Plenk, H., Jr., Franz, P., Hamzavi, J. S., Baumgartner, W., Czerny, C., & Ehrenberger, K. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709117786 · Cited by 105
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.007 · Cited by 99
Long-term auditory adaptation to a modified peripheral frequency map
Svirsky, M. A., Silveira, A. C. S. L., Neuburger, H. S., Teoh, S. W., & Suárez, H. (2004) · Acta Oto-Laryngologica · doi:10.1080/16512251.2004.12199906 · Cited by 87
Combined Electroacoustic Stimulation in Conventional Candidates for Cochlear Implantation
James, C. J., Fraysse, B., Déguine, O., Lenarz, T., Mawman, D. J., Ramos, Á., Ramsden, R. T., & Sterkers, O. (2006) · Audiology and Neurotology · doi:10.1159/000095615 · Cited by 86
Effects of Stimulation Rate with the Nucleus 24 ACE Speech Coding Strategy
Holden, L. K., Skinner, M. W., Holden, T. A., & Demorest, M. E. (2002) · Ear and Hearing · doi:10.1097/00003446-200210000-00008 · Cited by 86
Self-citationInsertional trauma of multichannel cochlear implants
Welling, D. B., Hinojosa, R., Gantz, B. J., & Lee, J. (1993) · The Laryngoscope · doi:10.1288/00005537-199309000-00010 · Cited by 75
Voie, A. H. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00493-8 · Cited by 71
Self-citationRebscher, S. J., Snyder, R. L., & Leake, P. A. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1365115 · Cited by 60
Whiting, B. R., Bae, K. T., & Skinner, M. W. (2001) · Radiology · doi:10.1148/radiol.2212010275 · Cited by 46
Self-citationClinical Evaluation of the Clarion CII HiFocus 1 with and Without Positioner
van der Beek, F. B., Boermans, P. P. B. M., Verbist, B. M., Briaire, J. J., & Frijns, J. H. M. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000188116.30954.21 · Cited by 43
Faulkner, A., Rosen, S., & Norman, C. (2006) · Ear and Hearing · doi:10.1097/01.aud.0000202357.40662.85 · Cited by 42
Camp, J. J., & Robb, R. A. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.348572 · Cited by 23
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Self-citationImpact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
Automatic Segmentation of Intracochlear Anatomy in Conventional CT
Noble, J. H., Labadie, R. F., Majdani, O., & Dawant, B. M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160262 · Cited by 168
“manually aligned with the image to identify electrode position [1], [23].”
MethodClinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
Noble, J. H., Gifford, R. H., Hedley-Williams, A. J., Dawant, B. M., & Labadie, R. F. (2014) · Audiology and Neurotology · doi:10.1159/000365273 · Cited by 162
Metadata
- Authors
- Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C.
- Venue
- Annals of Otology, Rhinology & Laryngology
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 116
- Issue
- 4
- Pages
- 2-24
- ISSN
- 0003-4894 (ISSN-L)
- 1943-572X
- OpenAlex
- W2013506837
- Cited by
- 243
- References
- 40
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.