The mechanical behaviour of brain tissue: Large strain response and constitutive modelling
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The non-linear mechanical behaviour of porcine brain tissue in large shear deformations is determined. An improved method for rotational shear experiments is used, producing an approximately homogeneous strain field and leading to an enhanced accuracy. Results from oscillatory shear experiments with a strain amplitude of 0.01 and frequencies ranging from 0.04 to 16 Hz are given. The immediate loss of structural integrity, due to large deformations, influencing the mechanical behaviour of brain tissue, at the time scale of loading, is investigated. No significant immediate mechanical damage is observed for these shear deformations up to strains of 0.45. Moreover, the material behaviour during complex loading histories (loading–unloading) is investigated. Stress relaxation experiments for strains up to 0.2 and constant strain rate experiments for shear rates from 0.01 to 1 s−1 and strains up to 0.15 are presented. A new differential viscoelastic model is used to describe the mechanical response of brain tissue. The model is formulated in terms of a large strain viscoelastic framework and considers non-linear viscous deformations in combination with non-linear elastic behaviour. This constitutive model is readily applicable in three-dimensional head models in order to predict the mechanical response of the intra-cranial contents due to an impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langlois, J. A., Rutland-Brown, W., & Thomas, K. E. (2006) · PsycEXTRA Dataset · doi:10.1037/e721222007-001 · Cited by 1,162
Regional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 635
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 635 · cited 1×
“The mechanical behaviour of brain tissue has been tested mostly in vitro in shear [1,4,5,9,10,13,24–30], compression [11,19,27] and tension [21].”
BackgroundBain, A. C., & Meaney, D. F. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324667 · Cited by 587 · cited 2×
“At these strain levels, functional damage may still occur (as observed by for example Bain and Meaney [3] and Morrison III et al. [23]) and at larger time scales also mechanical changes could develop.”
BackgroundA Review of the Severity Index
Versace, J. (1971) · SAE Technical Paper Series · doi:10.4271/710881 · Cited by 587 · cited 1×
“To assess the likelihood of head injury, in the early sixties, the Head Injury Criterion was developed [32] and is still used in most current test standards.”
MethodMechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501 · cited 1×
“Moreover, some in vivo results from probe indentation [14,22] and magnetic resonance elastography [15,17] have been reported.”
BackgroundAre in vivo and in situ brain tissues mechanically similar?
Gefen, A., & Margulies, S. S. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.032 · Cited by 417 · cited 1×
“Moreover, some in vivo results from probe indentation [14,22] and magnetic resonance elastography [15,17] have been reported.”
BackgroundA viscoelastic study of scalp, brain, and dura
Galford, J. E., & McElhaney, J. H. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90007-2 · Cited by 347
Rheological Response of Human Brain Tissue in Shear
Shuck, L. Z., & Advani, S. H. (1972) · Journal of Basic Engineering · doi:10.1115/1.3425588 · Cited by 308 · cited 2×
“On the other hand data presented by Shuck and Advani [28], Bilston et al.”
MethodThibault, K. L., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00122-5 · Cited by 299 · cited 6×
“[26], and approximately 50 percent more compliant than data presented by Arbogast and Margulies [1] and Thibault and Margulies [30].”
InfluentialConstitutive model of brain tissue suitable for finite element analysis of surgical procedures
Miller, K. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00010-x · Cited by 263 · cited 2×
“…in combination with Ogden hyper-elasticity to describe the viscoelastic behaviour of brain tissue (Darvish and Crandall, 2001; Mendis et al. , 1995; Miller, 1999; Nicolle et al. , 2004; Prange and Margulies, 2002; Takhounts et al. , 2003), and some propose a differential constitutive equation…”
Shear Properties of Human Brain Tissue
Donnelly, B. R., & Medige, J. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798289 · Cited by 237 · cited 2×
“Many researchers used an integral model, often in combination with Ogden hyper-elasticity to describe the viscoelastic behaviour of brain tissue [9,18,20,24,27,29], and some propose a differential constitutive equation [4,8,10].”
Material characterization of the brainstem from oscillatory shear tests
Arbogast, K. B., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00068-2 · Cited by 225 · cited 14×
“[26], and approximately 50 percent more compliant than data presented by Arbogast and Margulies [1] and Thibault and Margulies [30].”
InfluentialMorrison, B., Cater, H. L., Wang, C. C.-B., Thomas, F. C., Hung, C. T., Ateshian, G. A., & Sundstrom, L. E. (2003) · SAE Technical Paper Series · doi:10.4271/2003-22-0006 · Cited by 210 · cited 1×
“[23]) and at larger time scales also mechanical changes could develop.”
BackgroundNonlinear viscoelastic effects in oscillatory shear deformation of brain tissue
Darvish, K. K., & Crandall, J. R. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00101-1 · Cited by 198 · cited 5×
“…behaviour of brain tissue has been mostly tested in vitro in shear (Arbogast and Margulies, 1998; Bilston et al. , 2001; Brands et al. , 2000; Darvish and Crandall, 2001; Donnely and Medige, 1997; Galford and McElhaney, 1970; Nicolle et al. , 2004; Peters et al. , 1997; Shuck and Advani,…”
InfluentialNicolle, S., Lounis, M., & Willinger, R. (2004) · SAE Technical Paper Series · doi:10.4271/2004-22-0011 · Cited by 193 · cited 9×
“All shear experiments were preceded by a 10 cycle sinusoidal preconditioning with a frequency of 0.16 Hz and a strain amplitude of 0.01, which was previously determined to be the linear viscoelastic limit by Brands et al. (1999) and Nicolle et al. (2004).”
InfluentialBilston, L. E., Liu, Z., & Phan‐Thien, N. (2001) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2001038004004 · Cited by 188 · cited 6×
“[4] who found the same for a centred rotational configuration.”
BackgroundResultInfluentialShear linear behavior of brain tissue over a large frequency range
Nicolle, S., Lounis, M., Willinger, R., & Palierne, J. ‐. (2005) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2005042003003 · Cited by 176 · cited 6×
“[24], are approximately 10, 8, and 5 times stiffer, respectively.”
BackgroundResultInfluentialMechanical transient‐based magnetic resonance elastography
McCracken, P. J., Manduca, A., Felmlee, J., & Ehman, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20388 · Cited by 175 · cited 1×
“Moreover, some in vivo results from probe indentation [14,22] and magnetic resonance elastography [15,17] have been reported.”
BackgroundOn the Importance of Nonlinearity of Brain Tissue Under Large Deformations
Takhounts, E. G., Crandall, J. R., & Darvish, K. K. (2003) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2003-22-0005 · Cited by 138 · cited 5×
“…and Crandall, 2001; Donnely and Medige, 1997; Galford and McElhaney, 1970; Nicolle et al. , 2004; Peters et al. , 1997; Shuck and Advani, 1972; Takhounts et al. , 2003; Thibault and Margulies, 1998; Prange and Margulies, 2002), compression (Prange and Margulies, 2002; Estes and McElhaney,…”
InfluentialBrands, D. W. A., Peters, G. G., & Bovendeerd, P. H. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00243-4 · Cited by 115 · cited 2×
“[8] for the modelling of the mechanical behaviour of brain tissue.”
BackgroundSelf-citationA high-frequency shear device for testing soft biological tissues
Arbogast, K. B., Thibault, K. L., Pinheiro, B. S., Winey, K. I., & Margulies, S. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00023-7 · Cited by 112 · cited 2×
“Arbogast et al. (1997) did not (cid:2)nd any effect of temperature on the viscoelastic response of brain tissue.”
Modelling of non-isothermal viscoelastic flows
Peters, G. G., & Baaijens, F. F. (1997) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/s0377-0257(96)01511-x · Cited by 110 · cited 1×
“A general differential framework is used to describe the viscoelastic modes [25].”
MethodSelf-citationRegional Differences in Mechanical Properties of the Porcine Central Nervous System
Arbogast, K. B., & Margulies, S. S. (1997) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/973336 · Cited by 78 · cited 1×
“…with results presented by other authors, the values obtained in this study are in the lower part of the range reported in literature and are comparable with the data presented by Arbogast and Margulies (1997, 1998), Brands et al. (2000), Peters et al. (1997) and Thibault and Margulies (1998).”
Biomechanical Characterization of the Constitutive Relationship for the Brainstem
Arbogast, K. B., Meaney, D. F., & Thibault, L. E. (1995) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/952716 · Cited by 66 · cited 3×
“This is supported by the findings of other researchers who performed stress relaxation experiments [2,4,5,24,27,29].”
BackgroundResultBrands, D. W. A., Bovendeerd, P. H. M., & Wismans, J. S. H. M. (2002) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2002-22-0006 · Cited by 55 · cited 2×
“This constitutive model is readily applicable in three-dimensional head models, where the non-linear nature of the constitutive behaviour may have significant consequences for the predicted mechanical response [7].”
BackgroundSelf-citation“Palpation of the Brain” Using Magnetic Resonance Elastography
G-use, S. A., Dresner, M. A., Rossman, P. J., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (1999) · Cited by 35
Cited by
Effects of extracellular matrix viscoelasticity on cellular behaviour
Chaudhuri, O., Cooper-White, J., Janmey, P. A., Mooney, D. J., & Shenoy, V. B. (2020) · Nature · doi:10.1038/s41586-020-2612-2 · Cited by 2,224
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
The influence of substrate creep on mesenchymal stem cell behaviour and phenotype
Cameron, A. R., Frith, J. E., & Cooper-White, J. J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.003 · Cited by 428
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
Mechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
Self-citation
Metadata
- Authors
- Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M.
- Venue
- Biorheology: The Official Journal of the International Society of Biorheology
- Publisher
- SAGE Publications
- Published
- 2006-09
- Volume
- 43
- Issue
- 5
- Pages
- 623-636
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W2130410215
- Cited by
- 208
- References
- 27
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.