In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Arguably, a minimally invasive system using subcutaneous (s.c.) continuous glucose monitoring (CGM) and s.c. insulin delivery via insulin pump would be a most feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). Consequently, diabetes technology is focusing on developing an artificial pancreas using control algorithms to link CGM with s.c. insulin delivery. The future development of the artificial pancreas will be greatly accelerated by employing mathematical modeling and computer simulation. Realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner. Thus computer simulation testing of closed-loop control algorithms is regarded as a prerequisite to clinical trials of the artificial pancreas. In this paper, we present a system for in silico testing of control algorithms that has three principal components: (1) a large cohort of n = 300 simulated “subjects” ( n = 100 adults, 100 adolescents, and 100 children) based on real individuals' data and spanning the observed variability of key metabolic parameters in the general population of people with T1DM; (2) a simulator of CGM sensor errors representative of Freestyle Navigator™, Guardian RT, or Dexcom™ STS™, 7-day sensor; and (3) a simulator of discrete s.c. insulin delivery via OmniPod Insulin Management System or Deltec Cozmo® insulin pump. The system has been shown to represent adequate glucose fluctuations in T1DM observed during meal challenges, and has been accepted by the Food and Drug Administration as a substitute to animal trials in the preclinical testing of closed-loop control strategies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The characteristics of these”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“This UVA-PADOVA Type 1 Diabetes Simulator (S2008) emulated meal challenges and included a population of 300 in silico subjects (100 adults, 100 adolescents, 100 children).”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“However, the extensive use of computer simulation started in 2008 when a paradigm change occurred in the field of type 1 diabetes mellitus (T1DM): for the first time a computer model has been accepted by FDA as a substitute for preclinical trials of certain insulin treatments, including closed-loop algorithms. 4”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“Thus, the creation and validation of the in silico population involved proving that the parameters of the in silico population cover well key parameter distributions observed in vivo and provide comprehensive analysis of control performance.66,67”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“The tracer-based”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · cited 1×
“[20,30] mg/dl 3.”
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 433
(1985) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 417
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Research works printed but not linked: 4
- Clemens AH, 1977, Horm Metab Res., 23
- Fischer U, 1978, Endokrinologie., 71, 65
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Zisser H, Shwartz S, Ratner R, Wise J, Bailey T. Accuracy of a seven-day continuous glucose sensor compared to YSI blood glucose values. Proc 27th Workshop of the AIDPIT Study Group. Innsbruck, Austria. AIDPIT; 2008. p. S03. http://www.aidpit.org.
Cited by
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932
“73 Another powerful example is a computer simulator of type 1 diabetes mellitus, 74 which was accepted by the FDA as a substitute to animal trials for the pre-clinical testing of control strategies in artificial pancreas studies.”
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
“In particular, the main user interface window of the software (Figure 3) allows one (1) to define a testing scenario, that is, a schedule of meals with corresponding CHO amounts; (2) to select subjects for running the desired scenario; (3) to select the hardware, for example, a particular glucose sensor and insulin pu…”
MethodSelf-citationReinforcement Learning in Healthcare: A Survey
Yu, C., Liu, J., Nemati, S., & Yin, G. (2023) · ACM Computing Surveys · doi:10.1145/3477600 · Cited by 628
“se-insulin dynamics. Daskalaki et al. [115] presented an AC controller for the estimation of insulin infusion rate in silico trial based on the University of Virginia/Padova type 1 diabetes simulator [116]. In an evaluation of 12 day meal scenario for 10 adults, results showed that the approach could prevent hypoglyca…”
MethodArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
“Building on the large scale meal model developed in the healthy state (116,117), we have developed a type 1 diabetes simulator that, thanks to its ability to realistically describe intersubject variability, has been accepted by the Food and Drug Administration as a substitute of preclinical animal trials for certain i…”
MethodSelf-citationGarg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Self-citationYeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Challenges and Research Directions in Medical Cyber–Physical Systems
Lee, I., Sokolsky, O., Chen, S., Hatcliff, J., Jee, E., Kim, B., King, A., Mullen-Fortino, M., Park, S., Roederer, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165270 · Cited by 373
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
“The control algorithms used by studies 1 and 2—sCTR and eCTR, respectively—were designed and tested in silico using computer simulation (26), and each algorithm had a different focus: in study 1, the”
MethodSelf-citationIn silico clinical trials: how computer simulation will transform the biomedical industry
Viceconti, M., Henney, A., & Morley-Fletcher, E. (2016) · International Journal of Clinical Trials · doi:10.18203/2349-3259.ijct20161408 · Cited by 289
The UVA/Padova Type 1 Diabetes Simulator Goes From Single Meal to Single Day
Visentin, R., Campos-Náñez, E., Schiavon, M., Lv, D., Vettoretti, M., Breton, M., Kovatchev, B. P., Dalla Man, C., & Cobelli, C. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818757747 · Cited by 280
“In particular, in 2008 the US Food and Drug Administration (FDA) accepted the T1D simulator developed by Universities of Virginia (UVA) and Padova as a substitute for preclinical trials for certain insulin treatments, including closed-loop algorithms for artificial pancreas (AP).(2) This dramatically accelerated the A…”
BackgroundSelf-citationStatistical Tools to Analyze Continuous Glucose Monitor Data
Clarke, W., & Kovatchev, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0138 · Cited by 249
Self-citationSimulation Environment to Evaluate Closed-Loop Insulin Delivery Systems in Type 1 Diabetes
Wilinska, M. E., Chassin, L. J., Acerini, C. L., Allen, J. M., Dunger, D. B., & Hovorka, R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400117 · Cited by 244
Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2017) · Electronics · doi:10.3390/electronics6030065 · Cited by 237
“The proposed method has been evaluated in-silico over a population of 10 adults and 10 adolescents using a simulation approach [71].”
MethodZone Model Predictive Control: A Strategy to Minimize Hyper- and Hypoglycemic Events
Grosman, B., Dassau, E., Zisser, H. C., Jovanovič, L., & Doyle, F. J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400428 · Cited by 204
Computational Medicine: Translating Models to Clinical Care
Winslow, R. L., Trayanova, N., Geman, D., & Miller, M. I. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003528 · Cited by 202
“Models of glucose sensor errors for commercially available systems and insulin kinetics in the subcutaneous space were integrated with the glucose-insulin metabolism model ( 64 ).”
MethodKovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Self-citationChase, J. G., Preiser, J.-C., Dickson, J. L., Pironet, A., Chiew, Y. S., Pretty, C. G., Shaw, G. M., Benyo, B., Moeller, K., Safaei, S., et al. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0455-y · Cited by 189
“…variability of model parameters including physiological and behavioural changes using Bayesian virtual patients and cloning and statistical models [300, 301], which are part of the validation of the Padova type 1 diabetes simulator [99] recently approved for use in some regulatory submissions.”
BackgroundMethodInfluentialClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Self-citationChallenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
Modular Closed-Loop Control of Diabetes
Patek, S. D., Magni, L., Dassau, E., Hughes-Karvetski, C., Toffanin, C., De Nicolao, G., Del Favero, S., Breton, M., Man, C. D., Renard, E., et al. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192930 · Cited by 180
Self-citationFeasibility of Outpatient Fully Integrated Closed-Loop Control
Kovatchev, B. P., Renard, E., Cobelli, C., Zisser, H. C., Keith-Hynes, P., Anderson, S. M., Brown, S. A., Chernavvsky, D. R., Breton, M. D., Farret, A., et al. (2013) · Diabetes Care · doi:10.2337/dc12-1965 · Cited by 177
Self-citationContinuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“The UVA/Padova T1D simulator is a large-scale maximal computer model of glucose, insulin and glucagon dynamics in patients with T1D, described by 13 differential equations and provided with three different populations: 100 adult, 100 pediatric and 100 adolescent virtual subjects [52,53].”
BackgroundPinsker, J. E., Lee, J. B., Dassau, E., Seborg, D. E., Bradley, P. K., Gondhalekar, R., Bevier, W. C., Huyett, L., Zisser, H. C., & Doyle, F. J. (2016) · Diabetes Care · doi:10.2337/dc15-2344 · Cited by 151
“Food and Drug Administration–accepted Universities of Virginia/Padova metabolic simulator with 100 in silico adult subjects (26).”
BackgroundA Closed-Loop Artificial Pancreas Using Model Predictive Control and a Sliding Meal Size Estimator
Lee, H., Buckingham, B. A., Wilson, D. M., & Bequette, B. W. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300511 · Cited by 147
The Artificial Pancreas: How Closed-Loop Control Is Revolutionizing Diabetes
Haidar, A. (2016) · IEEE Control Systems · doi:10.1109/mcs.2016.2584318 · Cited by 165
“Multivariate distributions of the parameters of the glucose-insulin model were estimated and modified for the type 1 diabetes population, and random samples from these distributions used to generate virtual subjects [108].”
InfluentialMultivariable Adaptive Identification and Control for Artificial Pancreas Systems
Turksoy, K., Quinn, L., Littlejohn, E., & Cinar, A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2291777 · Cited by 162
Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring
Dassau, E., Cameron, F., Lee, H., Bequette, B. W., Zisser, H., Jovanovič, L., Chase, H. P., Wilson, D. M., Buckingham, B. A., & Doyle, F. J. (2010) · Diabetes Care · doi:10.2337/dc09-1487 · Cited by 143
“1252 DIABETES CARE, VOLUME 33, NUMBER 6, JUNE 2010 care.diabetesjournals.org prospectively using the UVa/Padova FDA-accepted (23) Metabolic Simulator and is currently under clinical evaluation that will be reported in a subsequent publication.”
MethodKanderian, S. S., Weinzimer, S., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300508 · Cited by 161
Turksoy, K., Bayrak, E. S., Quinn, L., Littlejohn, E., & Cinar, A. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0283 · Cited by 161
“The MPC method(5,12,13,15) can be implemented by using an in silico metabolic model.(16) Using the model created, meal and exercise information is given to the model as known disturbances during closed-loop operation.”
Control-Relevant Models for Glucose Control Using A Priori Patient Characteristics
van Heusden, K., Dassau, E., Zisser, H. C., Seborg, D. E., & Doyle, F. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2176939 · Cited by 160
Glucose-responsive insulin by molecular and physical design
Bakh, N. A., Cortinas, A. B., Weiss, M. A., Langer, R., Anderson, D. G., Gu, Z., Dutta, S., & Strano, M. S. (2017) · Nature Chemistry · doi:10.1038/nchem.2857 · Cited by 160
Gondhalekar, R., Dassau, E., & Doyle, F. J. (2016) · Automatica · doi:10.1016/j.automatica.2016.04.015 · Cited by 159
“To demonstrate we consider the numerical simulation of one subject using the UVA/Padova simulator (Dalla Man et al., 2014; Kovatchev et al., 2009).”
MethodWang, Y., Dassau, E., & Doyle, F. J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2024409 · Cited by 150
“In this section, ten extra in silico subjects presented in [20],”
BackgroundMethodBruttomesso, D., Farret, A., Costa, S., Marescotti, M. C., Vettore, M., Avogaro, A., Tiengo, A., Dalla Man, C., Place, J., Facchinetti, A., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300504 · Cited by 141
Self-citationTurksoy, K., Samadi, S., Feng, J., Littlejohn, E., Quinn, L., & Çınar, A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2446413 · Cited by 156
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
A Review of Emerging Technologies for the Management of Diabetes Mellitus
Zarkogianni, K., Litsa, E., Mitsis, K., Wu, P.-Y., Kaddi, C. D., Cheng, C.-W., Wang, M. D., & Nikita, K. S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2470521 · Cited by 112
“The IIAS has been in silico evaluated using the UVa T1DM simulator [100] and its performance has been compared against both the adaptive basal therapy presented in [41] and the artificial pancreatic b-cell,”
MethodBlood glucose control algorithms for type 1 diabetic patients: A methodological review
Lunze, K., Singh, T., Walter, M., Brendel, M. D., & Leonhardt, S. K. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.09.003 · Cited by 140
Validation of a model-based virtual trials method for tight glycemic control in intensive care
Chase, J. G., Suhaimi, F. M., Penning, S., Preiser, J., Compte, A. J. L., Lin, J., Pretty, C. G., Shaw, G. M., Moorhead, K. T., & Desaive, T. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-84 · Cited by 133
“Others have developed them for evaluating type 1 diabetes treatments [22,23] and in critical care [24], but none have been specifically validated in comparison to clinical trial or patient-specific outcomes.”
BackgroundModeling the glucose sensor error
Facchinetti, A., Del Favero, S., Sparacino, G., Castle, J. R., Ward, W. K., & Cobelli, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2284023 · Cited by 130
“according to [26], [27]; a precise assessment of the BG-to-IG kinetics can render enhancement and calibration methods more effective [10], [28]; finally, an accurate sensor error model is crucial in the type 1 diabetes simulator [29], [30] to test in silico AP closed-loop control algorithms.”
MethodSelf-citationBreton, M. D., Brown, S. A., Karvetski, C. H., Kollar, L., Topchyan, K. A., Anderson, S. M., & Kovatchev, B. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0333 · Cited by 128
“The CTR + HR algorithm was designed and tested in silico using computer simulation.(29)”
Self-citationZou, Y., Chu, Z., Guo, J., Liu, S., Ma, X., & Guo, J. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115103 · Cited by 131
Diurnal Pattern of Insulin Action in Type 1 Diabetes
Hinshaw, L., Dalla Man, C., Nandy, D. K., Saad, A., Bharucha, A. E., Levine, J. A., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., et al. (2013) · Diabetes · doi:10.2337/db12-1759 · Cited by 125
“This observation that SI varies in a subject-specific fashion is an important finding and will be incorporated into the type 1 diabetes simulator (33,34) to allow more reliable testing of closed-loop control algorithms.”
Self-citationBlood Glucose Level Prediction Using Physiological Models and Support Vector Regression
Bunescu, R., Struble, N., Marling, C., Shubrook, J., & Schwartz, F. (2013) · 2013 12th International Conference on Machine Learning and Applications · doi:10.1109/icmla.2013.30 · Cited by 106
“Most importantly, our best performing model was shown to make better predictions than all three diabetes experts involved in the study.”
MethodMessori, M., Incremona, G. P., Cobelli, C., & Magni, L. (2018) · IEEE Control Systems · doi:10.1109/mcs.2017.2766314 · Cited by 127
“Three “virtual populations” (children, adolescents, and adults), each comprised of 100 subjects, were included in the simulator [34].”
BackgroundMethodInfluentialSelf-citationPersonalized glucose forecasting for type 2 diabetes using data assimilation
Albers, D. J., Levine, M., Gluckman, B., Ginsberg, H., Hripcsak, G., & Mamykina, L. (2017) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005232 · Cited by 106
Advanced Insulin Bolus Advisor based on Run-To-Run Control and Case-Based Reasoning
(2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2331896 · Cited by 90
“The validity of the presented algorithm is demonstrated through an in-silico study using the UVa-Padova T1DM simulator [17], which has been modified to incorporate intrasubject variability, noise in the capillary blood measurements, and uncertainty in the carbohydrate intake.”
MethodVettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2746340 · Cited by 111
“The UVA/Padova T1D model was accepted by FDA as a tool to substitute pre-clinical trials for certain insulin treatments first in 2008 [19] and then in its updated version in 2013 [18].”
BackgroundMethodSelf-citationVelocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance
Gondhalekar, R., Dassau, E., & Doyle, F. J. (2018) · Automatica · doi:10.1016/j.automatica.2018.01.025 · Cited by 121
“5 using the Universities of Virginia (UVA)/Padova United States (US) Food & Drug Administration (FDA) accepted metabolic simulator (Kovatchev et al. 2009, Dalla Man et al. 2014).”
MethodInfluentialDeep Reinforcement Learning for Closed-Loop Blood Glucose ControlPreprint
Fox, I., Lee, J. M., Pop‐Busui, R., & Wiens, J. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.09051 · Cited by 119
“A more detailed explanation can be found in Kovatchev et al. (2009).”
BackgroundMethodInfluentialClosed-loop insulin delivery for treatment of type 1 diabetes
Elleri, D., Dunger, D. B., & Hovorka, R. (2011) · BMC Medicine · doi:10.1186/1741-7015-9-120 · Cited by 115
“In silico studies play a crucial role in complementing clinical testing, and address scenarios that cannot, for practical or ethical reasons, be tested in clinical studies [49-51].”
BackgroundCircadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113
“Most of these AP prototypes received the approval from the Food and Drug Administration or local ethical committees on the basis of in silico simulations of glucose metabolism.(13) In particular, in 2008 the Food and Drug Administration accepted the University of Virginia/Padova type 1 diabetes simulator (S2008)(13) a…”
Self-citationRun-to-Run Tuning of Model Predictive Control for Type 1 Diabetes Subjects: In Silico Trial
Magni, L., Forgione, M., Toffanin, C., Dalla Man, C., Kovatchev, B., De Nicolao, G., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300512 · Cited by 106
Self-citationSmart closed-loop drug delivery systems
Paci, M. M., Saha, T., Djassemi, O., Wu, S. T., Chua, C. Y. X., Wang, J., & Grattoni, A. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00328-z · Cited by 113
“For example, FDA-approved simulators based on glucose data during meals in individuals with T1D offer a platform for modelling the CLS behaviour across different age groups, aiding in the refinement and validation of these systems prior to clinical deployment 113 .”
Event-Triggered Model Predictive Control for Embedded Artificial Pancreas Systems
Chakrabarty, A., Zavitsanou, S., Doyle, F. J., & Dassau, E. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2707344 · Cited by 107
Lee, S., Kim, J., Park, S. W., Jin, S., & Park, S. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3002022 · Cited by 108
“of the 2008 version of the UVA/Padova simulator [22].”
An Insulin Infusion Advisory System Based on Autotuning Nonlinear Model-Predictive Control
Zarkogianni, K., Vazeou, A., Mougiakakou, S. G., Prountzou, A., & Nikita, K. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2157823 · Cited by 80
“In order to evaluate the performance and the robustness of the designed IIAS, the UVa T1DM simulator [21] has been used.”
BackgroundMethodVisentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103
“2Center for Diabetes Technology, University of Virginia, Charlottesville, Virginia.”
MethodInfluentialSelf-citationBreton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400309 · Cited by 103
Self-citationDesign and Evaluation of a Robust PID Controller for a Fully Implantable Artificial Pancreas
Huyett, L. M., Dassau, E., Zisser, H. C., & Doyle, F. J. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b01237 · Cited by 90
The Virtual Physiological Human: Ten Years After
Viceconti, M., & Hunter, P. J. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110915-114742 · Cited by 103
“The development of the sugar metabolism model now used in the FDA-approved Cobelli-Kovatchev pre-clinical simulator (96) started in 1979 (97).”
MethodMirshekarian, S., Shen, H., Bunescu, R., & Marling, C. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856940 · Cited by 101
A Closed-Loop Artificial Pancreas Based on Risk Management
Cameron, F., Bequette, B. W., Wilson, D. M., Buckingham, B. A., Lee, H., & Niemeyer, G. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500226 · Cited by 85
Wang, Q., Molenaar, P., Harsh, S., Freeman, K., Xie, J., Gold, C., Rovine, M., & Ulbrecht, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524080 · Cited by 90
Felizardo, V., García, N. M., Pombo, N. G. C. C., & Megdiche, I. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102120 · Cited by 99
Hughes, C. S., Patek, S. D., Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400513 · Cited by 89
Self-citationQuest for the Artificial Pancreas: Combining Technology with Treatment
Harvey, R. A., Wang, Y., Grosman, B., Percival, M. W., Bevier, W. C., Finan, D. A., Zisser, H., Seborg, D. E., Jovanovič, L., Doyle, F. J., et al. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935711 · Cited by 98
Automatic Detection and Estimation of Unannounced Meals for Multivariable Artificial Pancreas System
Samadi, S., Rashid, M., Turksoy, K., Feng, J., Hajizadeh, I., Hobbs, N., Lazaro, C., Sevil, M., Littlejohn, E., & Cinar, A. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0364 · Cited by 90
Of rodents and men: Species-specific glucose regulation and type 2 diabetes research
Chandrasekera, P. C. (2014) · ALTEX · doi:10.14573/1309231 · Cited by 89
“This is merely one example that “realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner” (Kovatchev et al., 2009).”
Danne, T., Tsioli, C., Kordonouri, O., Blaesig, S., Remus, K., Roy, A., Keenan, B., Lee, S. W., & Kaufman, F. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0327 · Cited by 91
Closed-Loop Artificial Pancreas Systems: Physiological Input to Enhance Next-Generation Devices
Kudva, Y. C., Carter, R. E., Cobelli, C., Basu, R., & Basu, A. (2014) · Diabetes Care · doi:10.2337/dc13-2066 · Cited by 83
“lengthy preclinical animal studies with in silico (computer-based) simulations and “simulators” (2,3) to expedite the approval processes with integrated efforts of all”
BackgroundMethodSelf-citationPatek, S. D., Bequette, B. W., Breton, M., Buckingham, B. A., Dassau, E., Doyle, F. J., Lum, J., Magni, L., & Zisser, H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300207 · Cited by 83
Self-citationModel-Free Machine Learning in Biomedicine: Feasibility Study in Type 1 Diabetes
Daskalaki, E., Diem, P., & Mougiakakou, S. G. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158722 · Cited by 95
Jacobs, P. G., El Youssef, J., Castle, J., Bakhtiani, P., Branigan, D., Breen, M., Bauer, D., Preiser, N., Leonard, G., Stonex, T., et al. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323248 · Cited by 82
Automated closed-loop control of diabetes: the artificial pancreas
Kovatchev, B. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0015-6 · Cited by 80
“The 2008 FDA acceptance of the UVA/ University of Padova computer simulator as a substitute to animal trials in the design and safety pre-clinical testing of AP controllers opened the field for rapid and cost-effective in silico experiments (Kovatchev et al. 2009a).”
BackgroundSelf-citationSafety Auxiliary Feedback Element for the Artificial Pancreas in Type 1 Diabetes
Revert, A., Garelli, F., Picó, J., Battista, H. D., Rossetti, P., Vehí, J., & Bondía, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2247602 · Cited by 88
“Finally, an in silico study using a cohort of ten adult virtual patients available in the educational version of the UVA simulator [48] is presented below.”
MethodInfluentialChase, J. G., Compte, A. J. L., Preiser, J.-C., Shaw, G. M., Penning, S., & Desaive, T. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-11 · Cited by 88
“Finally, physiologically relevant computer models have a longer, similar history in the broader diabetes field, primarily for research to gain patho-physiological insight rather than direct use in controlling glycemia [18,54,55,59-64].”
BackgroundSchaller, S., Willmann, S., Lippert, J., Schaupp, L., Pieber, T., Schuppert, A., & Eissing, T. (2013) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1038/psp.2013.40 · Cited by 71
Visentin, R., Man, C. D., & Cobelli, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2535241 · Cited by 86
“Several simulation tools have been developed (see [1] and [2]–[5] for a review), each one based on a comprehensive mathematical model and equipped with an in silico population.”
MethodSelf-citationControl to Range for Diabetes: Functionality and Modular Architecture
Kovatchev, B., Patek, S., Dassau, E., Doyle, F. J., Magni, L., De Nicolao, G., Cobelli, C., & Juvenile Diabetes Research Foundation Artificial Pancreas Consortium (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300509 · Cited by 83
Self-citationA Novel Method to Detect Pressure-Induced Sensor Attenuations (PISA) in an Artificial Pancreas
Baysal, N., Cameron, F., Buckingham, B. A., Wilson, D. M., Chase, H. P., Maahs, D. M., Bequette, B. W., for the In Home Closed-Loop Study Group (IHCL), Buckingham, B. A., Wilson, D. M., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814553267 · Cited by 78
“Facchinetti et al(17) present a Kalman-filter-based algorithm to detect sensor and infusion set anomalies and apply the approach in simulation studies using the UVa simulator.(18) In another study, different cases were investigated to evaluate the performances of CGM systems.”
MethodFrei, T., Chang, C.-H., Filo, M., Arampatzis, A., & Khammash, M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2122132119 · Cited by 86
Switched LPV Glucose Control in Type 1 Diabetes
Colmegna, P. H., Sánchez‐Peña, R., Gondhalekar, R., Dassau, E., & Doyle, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2487043 · Cited by 84
Parvinian, B., Scully, C., Wiyor, H., Kumar, A., & Weininger, S. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002329 · Cited by 75
Bekisz, S., & Geris, L. (2020) · Journal of Computational Science · doi:10.1016/j.jocs.2020.101198 · Cited by 83
Daskalaki, E., Prountzou, A., Diem, P., & Mougiakakou, S. G. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0093 · Cited by 71
Glucodensities: A new representation of glucose profiles using distributional data analysis
Matabuena, M., Petersen, A., Vidal, J. C., & Gude, F. (2021) · Statistical Methods in Medical Research · doi:10.1177/0962280221998064 · Cited by 82
“Traditionally, CGM was designed for the risk management in real-time for type 1 diabetes and the control of glucose values with insulin pumps (Kovatchev et al., 2009; Feig et al., 2017; DiMeglio et al., 2018).”
BackgroundA Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes
El Youssef, J., Castle, J., & Ward, W. K. (2009) · Algorithms · doi:10.3390/a2010518 · Cited by 69
“Based upon data obtained from over 200 subjects [27], this population model was then modified to describe a patient population of persons with type 1 diabetes from which individual models of virtual patients could be extracted for running a computer simulated trial [26].”
MethodA Century of Diabetes Technology: Signals, Models, and Artificial Pancreas Control
Kovatchev, B. (2019) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2019.04.008 · Cited by 80
Self-citationPeriodic-Zone Model Predictive Control for Diurnal Closed-Loop Operation of an Artificial Pancreas
Gondhalekar, R., Dassau, E., Zisser, H., & Doyle, F. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700605 · Cited by 80
Percival, M. W., Wang, Y., Grosman, B., Dassau, E., Zisser, H., Jovanovič, L., & Doyle, F. J. (2011) · Journal of Process Control · doi:10.1016/j.jprocont.2010.10.003 · Cited by 75
Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control.
McCall, A. L., & Farhy, L. S. (2013) · PubMed · Cited by 82
Insulin Patch Pumps: Their Development and Future in Closed-Loop Systems
Anhalt, H., & Bohannon, N. J. V. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0016 · Cited by 79
“demographic and metabolic parameters of weight, insulin requirements, fasting plasma glucose, insulin effect on glucose utilization, and the CHO ratio.(5) The CHO ratio represents the largest insulin bolus (in U=g) for CHO that does not lower plasma glucose to <95% of fasting plasma glucose after a meal containing 50…”
InfluentialResalat, N., El Youssef, J., Tyler, N., Castle, J., & Jacobs, P. G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0217301 · Cited by 78
Review and Analysis of Blood Glucose (BG) Models for Type 1 Diabetic Patients
Balakrishnan, N. P., Rangaiah, G. P., & Samavedham, L. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie2004779 · Cited by 72
High-fidelity phenotyping: richness and freedom from bias
Hripcsak, G., & Albers, D. J. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocx110 · Cited by 73
“65 Not many biomedical problems have the volume and accuracy of data required for accurate prediction from purely empirical models; instead, clinical data are often sparse, irregularly spaced, and inaccurate.”
BackgroundAutomatic regulatory control in type 1 diabetes without carbohydrate counting
Colmegna, P. H., Garelli, F., Battista, H. D., & Sánchez‐Peña, R. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.02.003 · Cited by 81
Dynamic Insulin on Board: Incorporation of Circadian Insulin Sensitivity Variation
Toffanin, C., Zisser, H., Doyle, F. J., & Dassau, E. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700415 · Cited by 76
Metadata
- Authors
- Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C.
- Affiliations
- University of Virginia (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- University of Padua (IT)
- Corresponding author
- Kovatchev, Boris P.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-01
- Volume
- 3
- Issue
- 1
- Pages
- 44-55
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2681269
- OpenAlex
- W2167160009
- Semantic Scholar
- 98207f5f90ddab161fa26eb0ed21911b4960fc86
- Cited by
- 760
- References
- 49
- Citations by year
- 2026: 26 · 2025: 23 · 2024: 29 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 50 · 2019: 55 · 2018: 54 · 2017: 51 · 2016: 48 · 2015: 48 · 2014: 64 · 2013: 66 · 2012: 49
- Type
- conference abstract
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01-DK-051562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, feedback control, artificial pancreas, continuous glucose monitoring, subcutaneous insulin administration, insulin pump, control algorithm simulation, meal challenge, glycemic variability
- MeSH terms
- Adolescent, Adult, Algorithms, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Drug Evaluation, Preclinical, Glucose, Humans, Insulin Infusion Systems, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.