In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Arguably, a minimally invasive system using subcutaneous (s.c.) continuous glucose monitoring (CGM) and s.c. insulin delivery via insulin pump would be a most feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). Consequently, diabetes technology is focusing on developing an artificial pancreas using control algorithms to link CGM with s.c. insulin delivery. The future development of the artificial pancreas will be greatly accelerated by employing mathematical modeling and computer simulation. Realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner. Thus computer simulation testing of closed-loop control algorithms is regarded as a prerequisite to clinical trials of the artificial pancreas. In this paper, we present a system for in silico testing of control algorithms that has three principal components: (1) a large cohort of n = 300 simulated “subjects” ( n = 100 adults, 100 adolescents, and 100 children) based on real individuals' data and spanning the observed variability of key metabolic parameters in the general population of people with T1DM; (2) a simulator of CGM sensor errors representative of Freestyle Navigator™, Guardian RT, or Dexcom™ STS™, 7-day sensor; and (3) a simulator of discrete s.c. insulin delivery via OmniPod Insulin Management System or Deltec Cozmo® insulin pump. The system has been shown to represent adequate glucose fluctuations in T1DM observed during meal challenges, and has been accepted by the Food and Drug Administration as a substitute to animal trials in the preclinical testing of closed-loop control strategies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The characteristics of these”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“This UVA-PADOVA Type 1 Diabetes Simulator (S2008) emulated meal challenges and included a population of 300 in silico subjects (100 adults, 100 adolescents, 100 children).”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“However, the extensive use of computer simulation started in 2008 when a paradigm change occurred in the field of type 1 diabetes mellitus (T1DM): for the first time a computer model has been accepted by FDA as a substitute for preclinical trials of certain insulin treatments, including closed-loop algorithms. 4”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“Thus, the creation and validation of the in silico population involved proving that the parameters of the in silico population cover well key parameter distributions observed in vivo and provide comprehensive analysis of control performance.66,67”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“The tracer-based”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · cited 1×
“[20,30] mg/dl 3.”
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 433
(1985) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 417
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Research works printed but not linked: 4
- Clemens AH, 1977, Horm Metab Res., 23
- Fischer U, 1978, Endokrinologie., 71, 65
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Zisser H, Shwartz S, Ratner R, Wise J, Bailey T. Accuracy of a seven-day continuous glucose sensor compared to YSI blood glucose values. Proc 27th Workshop of the AIDPIT Study Group. Innsbruck, Austria. AIDPIT; 2008. p. S03. http://www.aidpit.org.
Cited by
Items 401–500 of 870
A genetic algorithm tuned optimal controller for glucose regulation in type 1 diabetic subjects
Ghosh, S., & Gude, S. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2466 · Cited by 13
Campetelli, G., Lombarte, M., BASUALDO, M. S., & Rigalli, A. (2013) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2013.06.012 · Cited by 13
A differential evolution based approach for estimating minimal model parameters from IVGTT data
Ghosh, S. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.12.014 · Cited by 13
“The subject specific parameters estimated from the model provide valuable information about the feasibility and effectiveness of any glucose regulation strategy [3,4].”
MethodXie, J., & Wang, Q. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4041522 · Cited by 13
Predicting Insulin Treatment Scenarios with the Net Effect Method: Domain of Validity
Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0148 · Cited by 13
Self-citationGriva, L. O., Breton, M. D., Cherñavvsky, D. R., & BASUALDO, M. S. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2482 · Cited by 13
Self-citationFault Detection in Continuous Glucose Monitoring Sensors for Artificial Pancreas Systems
Yu, X., Rashid, M. M., Feng, J., Hobbs, N., Hajizadeh, I., Samadi, S., Sevil, M., Lazaro, C., Maloney, Z., & Çınar, A. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.09.279 · Cited by 13
Personal Health Systems for Diabetes Management, Early Diagnosis and Prevention
Zarkogianni, K., & Nikita, K. S. (2015) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-4666-8828-5.ch022 · Cited by 13
Shortcomings in the Evaluation of Blood Glucose Forecasting
Lee, J. M., Pop‐Busui, R., Lee, J. M., Fleischer, J., & Wiens, J. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3424665 · Cited by 12
“The UVA/Padova simulator is based on a physiological model of the glucoregulatory system and includes a large virtual patient “cohort” that spans the variability of key parameters in the general population [24].”
An Intraoperative Glucose Control Benchmark for Formal Verification
Chen, S., O’Kelly, M., Weimer, J. E., Sokolsky, O. V., & Lee, I. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.11.177 · Cited by 12
McGrath, T., Murphy, K. G., & Jones, N. S. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0736 · Cited by 12
Synthetic biomedical data generation in support of In Silico Clinical Trials
Simalatsar, A. (2023) · Frontiers in Big Data · doi:10.3389/fdata.2023.1085571 · Cited by 12
“The first version of the type 1 diabetes mellitus (T1DM) simulator of the University of Virginia/Padova was introduced in 2008 (Kovatchev et al., 2009).”
BackgroundMethodInfluentialLv, D., Kulkarni, S. D., Chan, A., Keith, S., Pettis, R. J., Kovatchev, B. P., Farhy, L. S., & Breton, M. D. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815573864 · Cited by 12
“Accurate representation of the parameter variation has allowed for the creation of an in silico population for preclinical trials, which has been accepted by the Food and Drug Administration (FDA) as a substitute of preclinical trials.(20,21) To our knowledge, the kinetics of the ID delivery route has never been descr…”
MethodSelf-citationA Run-to-Run Approach to Enhance Continuous Glucose Monitor Accuracy Based on Continuous Wear
Lee, J. B., Dassau, E., & Doyle, F. J. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.145 · Cited by 12
Neural inverse optimal control applied to type 1 diabetes mellitus patients
Leon, B. S., Alanís, A. Y., Sanchez, E. N., Tellez, F. O., & Ruiz-Velazquez, E. (2013) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-013-0109-8 · Cited by 12
Mhaskar, H. N., Naumova, V., & Pereverzev, S. V. (2013) · Applied Mathematics and Computation · doi:10.1016/j.amc.2013.09.015 · Cited by 12
Developing personalized empirical models for Type-I diabetes: An extended Kalman filter approach
Wang, Q., Harsh, S., Molenaar, P. C. M., & Freeman, K. A. (2013) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2013.6580278 · Cited by 12
“Our empirical models developed based on the extended Kalman filter (referred to as EKF-models in the rest of the paper) are evaluated using the training version of the FDA-approved UVa T1DM simulator [11] via thirty virtual subjects consisting of 10 adolescents, 10 adults and 10 children.”
MethodPropuesta de un algoritmo de control en lazo cerrado para la diabetes tipo 1
Rodríguez-Herrero, A. (2010) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.3681 · Cited by 12
Jaramillo, G., & Alejandra, M. (2011) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 12
Moscoso-Vásquez, M., Garcia‐Tirado, J., Colmegna, P. H., & Breton, M. D. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.274 · Cited by 11
Self-citationA new insulin-glucose metabolic model of type 1 diabetes mellitus: An in silico study
Fang, Q., Yu, L., & Li, P. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.03.009 · Cited by 11
Multi-level supervision and modification of artificial pancreas control system
Feng, J., Hajizadeh, I., Yu, X., Rashid, M. M., Turksoy, K., Samadi, S., Sevil, M., Hobbs, N., Brandt, R., Lazaro, C., et al. (2018) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2018.02.002 · Cited by 11
Verifying Conformance of Neural Network Models: Invited Paper
Narasimhamurthy, M., Kushner, T., Dutta, S., & Sankaranarayanan, S. (2019) · doi:10.1109/iccad45719.2019.8942151 · Cited by 11
“Besides their use in controls, models have been used extensively as part of testing and verification of AP systems [10, 36, 37, 48].”
MethodAdvancing treatment of retinal disease through in silico trials
Hernandez, R. J., Roberts, P. A., & El‐Bouri, W. K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acc8a9 · Cited by 11
“…ISCTs often revolve around testing differing dosing strategies either through having complex multi-arm ISCTs as is the case when studying optimal warfarin dosing [238], or through developing optimal control algorithms and testing those algorithms in an ISCT as with insulin control models [161].”
BackgroundArtificial pancreas for type 1 diabetes: Closed-loop algorithm based on Error Dynamics Shaping
Cormerais, H., & Richard, P.-Y. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.05.008 · Cited by 11
Digital mockups for the testing of a medical ventilator
Miller, B., Vahid, F., & Givargis, T. (2012) · International Health Informatics Symposium · doi:10.1145/2110363.2110473 · Cited by 11
LMI Based Robust Blood Glucose Regulation in Type-1 Diabetes Patient with Daily Multi-meal Ingestion
Mandal, S., Bhattacharjee, A., & Sutradhar, A. (2014) · Journal of The Institution of Engineers (India) Series B · doi:10.1007/s40031-014-0083-2 · Cited by 11
Yu, C., & Zhao, C. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.00534 · Cited by 11
“As a proof-of-concept study, the simulated data are generated from the FDA-accepted University of Virginia/University of Padova (UVA/Padova) metabolic simulator with a 5 min sampling interval (Kovatchev et al., 2009).”
MethodModel predictive control with event-triggered communication for an embedded artificial pancreas
Chakrabarty, A., Zavitsanou, S., Doyle, F. J., & Dassau, E. (2017) · IEEE Conference on Control Technology and Applications (CCTA) · doi:10.1109/ccta.2017.8062517 · Cited by 11
“In this section, we report the clinical scenario used to test the proposed ETC-based AP on ten subjects from the academic version of the UVA/Padova metabolic simulator [25].”
MethodInverse Optimal Control Using A Neural Multi-Step Predictor For T1DM Treatment
Ríos, Y. Y., García-Rodríguez, J. A., Sánchez, O. D., Sanchez, E. N., Alanís, A. Y., Ruiz-Velazquez, E., & Arana‐Daniel, N. (2018) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2018.8489197 · Cited by 11
Monitoring and fault detection of continuous glucose sensor measurements
Turksoy, K., Quinn, L., Littlejohn, E., & Çınar, A. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172133 · Cited by 11
“Preprocessing of Data As a proof-of-concept study, seven different three-day CL scenarios are generated with a five-minute sampling time tested on a virtual patient using the UVa/Padova metabolic simulator [28].”
MethodAsare, P., Dickerson, R. F., Wu, X., Lach, J., & Stankovic, J. A. (2013) · Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2517351.2517392 · Cited by 8
The impact of insulin pharmacokinetics and pharmacodynamics on the closed-loop artificial pancreas
Lee, J. J., Dassau, E., Zisser, H., Tamborlane, W. V., WEINZIMER, S. A., & Doyle, F. J. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6759870 · Cited by 11
“controller time constant ( C W varying from 25 min to 175 min) on 10 in silico adult subjects from the UVA/Padova simulator [22].”
MethodHussain, F., Jha, S. K., Jha, S., & LANGMEAD, C. J. (2014) · International Journal of Bioinformatics Research and Applications · doi:10.1504/ijbra.2014.062998 · Cited by 11
Testing PFC Controller On A Well Validated In Silico Model of a Type I Diabetic Patient
Campetelli, G., Zumoffen, D., BASUALDO, M. S., & Rigalli, A. (2010) · IFAC Proceedings Volumes · doi:10.3182/20100705-3-be-2011.00042 · Cited by 11
Closed-Loop Insulin Delivery: We're “Virtually” There
Tamborlane, W. V. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0261 · Cited by 11
“More recently, at the University of Virginia, Boris Kovatchev and associates developed computer models of glucose metabolism in people with type 1 diabetes that could be used for in silico testing of closed-loop controller algorithms.(4) When the University of Virginia in silico model was accepted by the U.”
Metabolic Models, in Silico Trials, and Algorithms
Çınar, A., Basu, A., Bequette, B. W., Breton, M. D., Buckingham, B. A., Cengiz, E., Cobelli, C., Dassau, E., Doyle, F. J., Fabris, C., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251338300 · Cited by 10
Self-citationA differential simulator using past clinical trial data to run simulated clinical trials
Cameron, F., Baysal, N., & Bequette, B. W. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172135 · Cited by 10
“We can then simulate clinical trials by using the proposed controller to determine what insulin to provide to these models[12].”
MethodSystems biology platform for efficient development and translation of multitargeted therapeutics
Azer, K., & Leaf, I. A. (2023) · Frontiers in Systems Biology · doi:10.3389/fsysb.2023.1229532 · Cited by 12
Chalumuri, Y. R., Arabidarrehdor, G., Tivay, A., Sampson, C. M., Khan, M., Kinsky, M. P., Kramer, G. C., Hahn, J., Scully, C. G., & Bighamian, R. (2024) · IEEE Access · doi:10.1109/access.2024.3395008 · Cited by 10
Nonlinear glucose–insulin control considering delays—Part II: Control algorithm
Mythreyi, K., Subramanian, S. C., & Kumar, R. K. (2014) · Control Engineering Practice · doi:10.1016/j.conengprac.2014.02.012 · Cited by 11
Leon, B. S., Alanís, A. Y., Sanchez, E. N., Tellez, F. O., & Ruiz-Velazquez, E. (2014) · Intelligent Automation & Soft Computing · doi:10.1080/10798587.2014.891307 · Cited by 10
“These schemes include the classical PID control scheme [12–16], the MPC (model predictive control) [13,17,18], MPILC (A combination of iterative learning control and MPC) [19] among others.”
MethodReal-Time Insulin Bolusing for Unannounced Meals Using CGM Measurements
Turksoy, K., & Çınar, A. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.142 · Cited by 10
Shaping the MPC Cost Function for Superior Automated Glucose Control
Lee, J. B., Gondhalekar, R., Dassau, E., & Doyle, F. J. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.07.283 · Cited by 10
“The US FDA-accepted Universities of Virginia/Padova metabolic simulator (Kovatchev et al. 2009) was utilized to evaluate the proposed controller in silico.”
MethodDesign of an online-tuned model based compound controller for a fully automated artificial pancreas
Bhattacharjee, A., Easwaran, A., Leow, M. K., & Cho, N. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-01972-5 · Cited by 10
Çankaya, N., & Aydoğdu, Ö. (2020) · IEEE Access · doi:10.1109/access.2020.3015454 · Cited by 10
“These algorithms were also enhanced by new approaches such as deep learning [18]–[20].”
MethodKoutný, T., & Úbl, M. (2020) · Procedia Computer Science · doi:10.1016/j.procs.2020.10.048 · Cited by 10
Godoy, J. L., Sereno, J. E., & Rivadeneira, P. S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102715 · Cited by 11
Main glucose hepatic fluxes in healthy subjects predicted from a phenomenological-based model
Builes-Montaño, C. E., Lema-Pérez, L., Garcia‐Tirado, J., & Álvarez, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105232 · Cited by 10
Camerlingo, N., Vettoretti, M., Favero, S. D., Facchinetti, A., Choudhary, P., & Sparacino, G. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106862 · Cited by 10
Linear Parameter-Varying Control to Minimize Risks in Type 1 Diabetes
Colmegna, P. H., & Sánchez‐Peña, R. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.00628 · Cited by 10
Mandal, S., & Sutradhar, A. (2015) · International Journal of Dynamics and Control · doi:10.1007/s40435-015-0160-7 · Cited by 10
Physiological models for artificial pancreas development
VISENTIN, R., Schiavon, M., Basu, R., Basu, A., Man, C. D., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00015-6 · Cited by 11
Self-citationPersonal Health Systems for Diabetes Management, Early Diagnosis and Prevention
Zarkogianni, K., & Nikita, K. S. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-6198-9.ch012 · Cited by 10
Clinically Relevant Hypoglycemia Prediction Metrics for Event Mitigation
Harvey, R. A., Dassau, E., Zisser, H., Bevier, W. C., Seborg, D. E., Jovanovič, L., & Doyle, F. J. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0198 · Cited by 10
“An in silico study to mimic hypoglycemia caused by an over-bolus was conducted using the Food and Drug Administration–accepted UVA/Padova metabolic simulator set of 10 published subjects.(18) The simulated CGM, with preprogrammed noise, was used for all calculations.”
Smith Predictor Sliding Mode Closed-loop Glucose Controller in Type 1 Diabetes
Abu-Rmileh, A., & García-Gabín, W. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.01213 · Cited by 10
“The modified model was implemented in the UVa/Padova metabolic simulator (Kovatchev et al. [2009]), designed to support the development of closed-loop artificial pancreas. In addition to the patient model, the simulator incorporates a sensor-related errors model to account for sensor noise and measurements errors (Kov…”
MethodLiu, S.-W., Huang, H., Lin, C.-H., & Chien, I. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie202308w · Cited by 10
Behavior monitoring under uncertainty using Bayesian surprise and optimal action selection
Ávila, L. O., & Martínez, E. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.04.031 · Cited by 10
Frei, T., Chang, C.-H., Filo, M., Arampatzis, A., & Khammash, M. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.12.06.412304 · Cited by 11
“for both T1DM [42, 43] and T2DM [38], which originated from the UVA-PADOVA Type 1 Diabetes Simulator (S2008) and its updated versions [42, 44].”
BackgroundVisentin, R., Schiavon, M., Giegerich, C., Klabunde, T., Man, C. D., & Cobelli, C. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513234 · Cited by 9
“In particular, thanks to its ability to reproduce glucose variability characterizing the T1D population [2],[3], the University of Virginia (UVA) and Padova T1D Simulator has been widely used to test artificial pancreas algorithms and, recently, glucose sensors and novel insulin formulations [4].”
BackgroundSelf-citationRenuse, S., Benson, L. M., Vanderboom, P. M., RUCHI, F., YADAV, Y. R., Johnson, K. L., Brown, B. C., Peterson, J. A., Basu, R., McCormick, D., et al. (2022) · Clinical Proteomics · doi:10.1186/s12014-022-09344-2 · Cited by 9
“The proposed method will also allow, for the first time, to precisely determine the key paracrine interaction, its dysregulation and help develop an explicit glucagon model for testing in the FDA-approved T1D simulator [17, 18] prior to clinical trials.”
MethodCappon, G., Facchinetti, A., Sparacino, G., & Favero, S. D. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856846 · Cited by 9
A Multiple Hypothesis Approach to Estimating Meal Times in Individuals With Type 1 Diabetes
Corbett, J. P., Breton, M. D., & Patek, S. D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883267 · Cited by 9
Self-citationEstremera, E., Beneyto, A., Cabrera, A., Contreras, I., & Vehí, J. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107568 · Cited by 9
SugarNet: Personalized blood glucose forecast with a Fourier Kolmogorov–Arnold network
Zhu, B., & Connor, C. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.127476 · Cited by 10
SystematicallyIn SilicoComparison of Unihormonal and Bihormonal Artificial Pancreas Systems
Gao, X., Ning, H., & Wang, Y. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/712496 · Cited by 9
“The dynamic model for a virtual subject [26] consists of a glucose subsystem, an insulin subsystem, a meal subsystem, and a glucagon subsystem.”
MethodPerformance Assessment of Model-Based Artificial Pancreas Control Systems
Feng, J., Turksoy, K., & Çınar, A. (2015) · Lecture notes in bioengineering · doi:10.1007/978-3-319-25913-0_13 · Cited by 9
“Significant progress has been made in AP systems [2, 4, 7, 17, 25, 30].”
BackgroundMethodGaetano, A. D., Gaz, C., & Panunzi, S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0211331 · Cited by 9
Artificial Pancreas Control for Diabetes using TD3 Deep Reinforcement Learning
Mackey, A., & Furey, E. (2022) · Irish Signals and Systems Conference · doi:10.1109/issc55427.2022.9826219 · Cited by 9
Tailoring the Padova Type 2 Diabetes Simulator for Treatment Guidance in Target Populations
VISENTIN, R., Schiavon, M., Bonet, J., Riz, M., Wagenhuber, B., & Man, C. D. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3352153 · Cited by 9
“An example of such in silico tools is the UVA/Padova type 1 diabetes (T1D) simulator [2], [3], [4] that has been accepted and widely used as decision support system for testing several diabetes technology treatments, such as artificial pancreas prototypes (e.g., [5], [6], [7]) and, more recently,…”
MethodPatient-specific deep offline artificial pancreas for blood glucose regulation in type 1 diabetes
Deng, Y., Arao, K., Mantzoros, C. S., & Karniadakis, G. E. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100633 · Cited by 9
Steps towards a closed-loop artificial pancreas
Bequette, B. W., Baysal, N., Howsmon, D. P., & Cameron, F. (2015) · Annual Northeast Biomedical Engineering Conference · doi:10.1109/nebec.2015.7117081 · Cited by 9
A Robust Receding Horizon Control Approach to Artificial Glucose Control for Type 1 Diabetes
Penet, M., Guéguen, H., & Belmiloudi, A. (2013) · IFAC Proceedings Volumes · doi:10.3182/20130904-3-fr-2041.00154 · Cited by 9
“IN SILICO VALIDATION The proposed approach is tested thanks to numerical simulation on a virtual patient testing platform (Uva/Padova T1DM metabolic simulator the distributed version [B.P.Kovatchev et al., 2009]).”
MethodGlucose prediction for type 1 diabetes using KLMS algorithm
Sun, X., Yu, X., Liu, J., & Wang, H. (2017) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2017.8027498 · Cited by 9
“3 Simulation Results The time series data sets for simulation analyses are generated from the UVa/Padova metabolic simulator [12].”
MethodLombarte, M., Lupo, M., Brenda, L. F., Campetelli, G., Marília, A. R. B., BASUALDO, M. S., & Rigalli, A. (2017) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2017.12.001 · Cited by 9
Úbl, M., Koutný, T., Cioppa, A. D., Falco, I. D., Tarantino, E., & Scafuri, U. (2022) · Sensors · doi:10.3390/s22239445 · Cited by 9
Online Glucose Prediction in Type-1 Diabetes by Neural Network Models
Zecchin, C. (2014) · Padua@research (University of Padova) · Cited by 10
The impact of glucose sensing dynamics on the closed-loop artificial pancreas
Huyett, L. M., Dassau, E., Zisser, H., & Doyle, F. J. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172137 · Cited by 9
“I. INTRODUCTION Type 1 diabetes mellitus (T1DM) is a metabolic disorder characterized by the destruction of the pancreatic beta cells.”
MethodInfluentialRevert, A., Rossetti, P., Calm, R., Vehí, J., & Bondía, J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400617 · Cited by 9
Noguchi, C. C. Y., Hashimoto, S., Furutani, E., & Sumi, S. (2016) · SICE Journal of Control Measurement and System Integration · doi:10.9746/jcmsi.9.201 · Cited by 9
“Mathematical modeling of glucose-insulin metabolism in diabetes is an essential instrument for the understanding of the disease [1] and the development of diabetes-related technologies including model-based blood glucose (BG) control algorithms [2].”
BackgroundDesign and Validation of an Open-Source Closed-Loop Testbed for Artificial Pancreas SystemsPreprint
Zhou, X., Kouzel, M., Ren, H., & Alemzadeh, H. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2208.06479 · Cited by 9
“The UVAPadova simulator [11] was the first APS simulator to be approved by the FDA in 2008 as a substitute for animal testing.”
MethodAhmadasas, M., Inanc, E., Ozkara, E., Siket, M., Rashid, M. M., Bilgic, M., Quinn, L., & Çınar, A. (2025) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2025.101033 · Cited by 8
A perfectly imperfect engine: Utilizing the digital twin paradigm in pulmonary hypertension
Walker, M., Moore, H., Ataya, A., Pham, A. T., Corris, P. A., Laubenbacher, R., & Bryant, A. J. (2024) · Pulmonary Circulation · doi:10.1002/pul2.12392 · Cited by 8
Learning control-ready forecasters for Blood Glucose Management
Rubin‐Falcone, H., Lee, J. M., & Wiens, J. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108995 · Cited by 10
Synthesis of insulin pump controllers from safety specifications using Bayesian model validation
Jha, S. K., Dutta, R. G., LANGMEAD, C. J., Jha, S., & Sassano, E. R. (2012) · International Journal of Bioinformatics Research and Applications · doi:10.1504/ijbra.2012.048964 · Cited by 8
“For example, one model (Kovatchev et al., 2009) uses 26 in silico parameters while another model (Wilinska et al.”
BackgroundMethodRapid Prototyping of Neuro-Fuzzy Inverse Optimal Control as Applied to T1DM Patients
Ríos, Y. Y., García-Rodríguez, J. A., Sanchez, E. N., Alanís, A. Y., & Ruiz-Velazquez, E. (2018) · IEEE Latin American Conference on Computational Intelligence (LA-CCI) · doi:10.1109/la-cci.2018.8625241 · Cited by 8
“Since 2008, this simulator is approved by the Food and Drug Administration (FDA) for the preclinical testing of control strategies in Artificial Pancreas [17], [18].”
BackgroundGallardo-Hernández, A. G., Gonzalez-Olvera, M. A., Revilla, M., Escobar, J. A., Castellanos-Fuentes, M., & Leder, R. S. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.03.028 · Cited by 8
van Sloun, B., Goossens, G. H., Erdõs, B., O’Donovan, S. D., Singh‐Povel, C. M., Geurts, J. M. W., van Riel, N. A. W., & Arts, I. C. W. (2023) · iScience · doi:10.1016/j.isci.2023.106218 · Cited by 8
A classification-based fault detection method for Continuous glucose monitoring (CGM)
Song, G., Zhao, C., & Sun, Y. (2016) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2016.7578449 · Cited by 8
Wilinska, M. E., & Hovorka, R. (2014) · Lecture notes in bioengineering · doi:10.1007/978-3-642-54464-4_6 · Cited by 8
Rojas, R., García-Gabín, W., & Bequette, B. W. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.03147 · Cited by 8
Zhao, C., Dassau, E., Harvey, R. A., Seborg, D. E., & Doyle, F. J. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.02330 · Cited by 8
“Simulation studies with the FDAaccepted University of Virginia (UVA)/University of Padova metabolic simulator (Kovatchev et al., 2009) demonstrate the relevance of the proposed method.”
MethodOptimization of Insulin Dosing in Patients with Type 1 Diabetes Mellitus
Zavitsanou, S., Mantalaris, A., Georgiadis, M. C., & Pistikopoulos, E. N. (2014) · Computer-aided chemical engineering/Computer aided chemical engineering · doi:10.1016/b978-0-444-63455-9.50078-7 · Cited by 8
Artificial Pancreas: from Control-to-Range to Control-to-Target
Incremona, G. P., Messori, M., Toffanin, C., Cobelli, C., & Magni, L. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1152 · Cited by 9
Self-citationLuo, S., & Zhao, C. (2019) · Cited by 8
Penet, M. (2013) · theses.fr (ABES) · doi:10.70675/f8c3f521z3233z4b7dza049za351e75a0d5d · Cited by 8
Simulating Realistic Continuous Glucose Monitor Time Series By Data Augmentation
Gomez, L., Toye, A. A., Hum, R. S., & Kleinberg, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231181138 · Cited by 7
Basu, S., Legault, M., Romero, A., & Precup, D. (2023) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v37i12.26650 · Cited by 7
Deep Reinforcement Learning Control of Type-1 Diabetes with Cross-Patient Generalization
Atanasious, M. M. H., Becchetti, V., Baldisseri, F., Menegatti, D., & Wrona, A. (2024) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med61351.2024.10566186 · Cited by 8
“Further details can be found in [23].”
Filo, M., Gupta, A., & Khammash, M. (2024) · Science Advances · doi:10.1126/sciadv.adl5439 · Cited by 7
“( 47 , 48 , 61 ) as the controlled process.”
Method
Metadata
- Authors
- Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C.
- Affiliations
- University of Virginia (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- University of Padua (IT)
- Corresponding author
- Kovatchev, Boris P.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-01
- Volume
- 3
- Issue
- 1
- Pages
- 44-55
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2681269
- OpenAlex
- W2167160009
- Semantic Scholar
- 98207f5f90ddab161fa26eb0ed21911b4960fc86
- Cited by
- 760
- References
- 49
- Citations by year
- 2026: 26 · 2025: 23 · 2024: 29 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 50 · 2019: 55 · 2018: 54 · 2017: 51 · 2016: 48 · 2015: 48 · 2014: 64 · 2013: 66 · 2012: 49
- Type
- conference abstract
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01-DK-051562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, feedback control, artificial pancreas, continuous glucose monitoring, subcutaneous insulin administration, insulin pump, control algorithm simulation, meal challenge, glycemic variability
- MeSH terms
- Adolescent, Adult, Algorithms, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Drug Evaluation, Preclinical, Glucose, Humans, Insulin Infusion Systems, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.