In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Arguably, a minimally invasive system using subcutaneous (s.c.) continuous glucose monitoring (CGM) and s.c. insulin delivery via insulin pump would be a most feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). Consequently, diabetes technology is focusing on developing an artificial pancreas using control algorithms to link CGM with s.c. insulin delivery. The future development of the artificial pancreas will be greatly accelerated by employing mathematical modeling and computer simulation. Realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner. Thus computer simulation testing of closed-loop control algorithms is regarded as a prerequisite to clinical trials of the artificial pancreas. In this paper, we present a system for in silico testing of control algorithms that has three principal components: (1) a large cohort of n = 300 simulated “subjects” ( n = 100 adults, 100 adolescents, and 100 children) based on real individuals' data and spanning the observed variability of key metabolic parameters in the general population of people with T1DM; (2) a simulator of CGM sensor errors representative of Freestyle Navigator™, Guardian RT, or Dexcom™ STS™, 7-day sensor; and (3) a simulator of discrete s.c. insulin delivery via OmniPod Insulin Management System or Deltec Cozmo® insulin pump. The system has been shown to represent adequate glucose fluctuations in T1DM observed during meal challenges, and has been accepted by the Food and Drug Administration as a substitute to animal trials in the preclinical testing of closed-loop control strategies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The characteristics of these”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“This UVA-PADOVA Type 1 Diabetes Simulator (S2008) emulated meal challenges and included a population of 300 in silico subjects (100 adults, 100 adolescents, 100 children).”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“However, the extensive use of computer simulation started in 2008 when a paradigm change occurred in the field of type 1 diabetes mellitus (T1DM): for the first time a computer model has been accepted by FDA as a substitute for preclinical trials of certain insulin treatments, including closed-loop algorithms. 4”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [4]
In the citing paper
“Thus, the creation and validation of the in silico population involved proving that the parameters of the in silico population cover well key parameter distributions observed in vivo and provide comprehensive analysis of control performance.66,67”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
In the citing paper
“The tracer-based”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [66]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · cited 1×
“[20,30] mg/dl 3.”
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 433
(1985) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 417
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Research works printed but not linked: 4
- Clemens AH, 1977, Horm Metab Res., 23
- Fischer U, 1978, Endokrinologie., 71, 65
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Zisser H, Shwartz S, Ratner R, Wise J, Bailey T. Accuracy of a seven-day continuous glucose sensor compared to YSI blood glucose values. Proc 27th Workshop of the AIDPIT Study Group. Innsbruck, Austria. AIDPIT; 2008. p. S03. http://www.aidpit.org.
Cited by
Items 201–300 of 870
In Silico Closed-Loop Control Validation Studies for Optimal Insulin Delivery in Type 1 Diabetes
Zavitsanou, S., Mantalaris, A., Georgiadis, M. C., & Pistikopoulos, E. N. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2427991 · Cited by 41
“The second is UVa/Padova Simulator model [17] for ten adult patients.”
MethodArtificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses
Sánchez‐Peña, R., Colmegna, P. H., Garelli, F., Battista, H. D., García-Violini, D., Moscoso-Vásquez, M., Rosales, N., Fushimi, E., Campos-Náñez, E., Breton, M. D., et al. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818786488 · Cited by 41
Self-citationClosed loop developments to improve glucose control at home
Renard, É., Cobelli, C., & Kovatchev, B. P. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.09.009 · Cited by 40
“[21] Kovatchev BP, Breton MD, Dalla Man C, Cobelli C.”
BackgroundSelf-citationModel-based analysis of postprandial glycemic response dynamics for different types of food
Wesseling-Rozendaal, Y. J. W., Maas, A. H., van Pul, C., Cottaar, E. J. E., Haak, H. R., Hilbers, P. A. J., & van Riel, N. A. W. (2018) · Clinical Nutrition Experimental · doi:10.1016/j.yclnex.2018.01.003 · Cited by 42
“However, in contrast to other population-based glucose-insulin models, our PBDM allows for a subject-specific framework in which postprandial data can be analyzed in a personalized setting, and could be employed for the use in in silico clinical trials with virtual patients [60,61] We have shown that our PBDM can easi…”
MethodModeling and Control of Diabetes: Towards the Artificial Pancreas
Nicolao, G. D., Magni, L., Man, C. D., & Cobelli, C. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.03036 · Cited by 40
Self-citationLeber, A. J., Hontecillas, R., Abedi, V., Tubau‐Juni, N., Zoccoli-Rodriguez, V., Stewart, C., & Bassaganya-Riera, J. (2017) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.05.003 · Cited by 39
Glucose-insulin model identified in free-living conditions for hypoglycaemia prevention
Toffanin, C., Favero, S. D., Aiello, E. M., Messori, M., Cobelli, C., & Magni, L. (2018) · Journal of Process Control · doi:10.1016/j.jprocont.2018.02.003 · Cited by 39
Self-citationKovatchev, B. P. (2012) · Scientifica · doi:10.6064/2012/283821 · Cited by 39
“) were tailored to span a wide range of intersubject variability approximating the variability observed in people in vivo [150].”
BackgroundSelf-citationModel-based personalization scheme of an artificial pancreas for Type 1 diabetes applications
Lee, J. B., Dassau, E., Seborg, D. E., & Doyle, F. J. (2013) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2013.6580276 · Cited by 38
“The controllers are evaluated as a part of a ten subject study using the Food and Drug Administration (FDA) accepted University of Virginia and Padova (UVA/Padova) metabolic simulator [17].”
MethodYu, X., Littlejohn, E., Quinn, L., Çınar, A., Rashid, M. M., Feng, J., Hobbs, N., Hajizadeh, I., Samadi, S., Sevil, M., et al. (2018) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2018.2843785 · Cited by 38
“For the evaluation of in-silico subjects, the online prediction of BGC values is performed using the academic version of the FDA approved UVa/Padova metabolic simulator [58], which has 30 in-silico subjects (ten adults, ten adolescents, and ten children).”
MethodMeneghetti, L., Facchinetti, A., & Favero, S. D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3004270 · Cited by 38
Applicability Results of a Nonlinear Model-Based Robust Blood Glucose Control Algorithm
Kovács, L., Szalay, P., Almássy, Z., & Barkai, L. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700316 · Cited by 38
Inverse optimal neural control of blood glucose level for type 1 diabetes mellitus patients
Leon, B. S., Alanís, A. Y., Sanchez, E. N., Tellez, F. O., & Ruiz-Velazquez, E. (2012) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2012.02.011 · Cited by 38
Kovatchev, B. P., Lobo, B. J., Fabris, C., Ganji, M., Fathi, A. E., Breton, M. D., Kanapka, L. G., Kollman, C., Battelino, T., & Beck, R. W. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0404 · Cited by 37
“…for in silico testing of automated insulin delivery algorithms, which is recognized by the FDA as a substitute for animal preclinical trials, 19,20 and (2) we have shown 15 and extensively validated 16 that the multitude of daily CGM pro fi les can be approximated by a fi nite set of 483…”
Self-citationVisentin, R., Giegerich, C., Jäger, R., Dahmen, R., Boss, A., Grant, M., Dalla Man, C., Cobelli, C., & Klabunde, T. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0128 · Cited by 36
“Can the efficacy of TI be improved by changing the dosing regimen? Could an improvement be clinically significant? Which titration rule would be optimal to guide patients to their individual dose with modified dosing regimens? The availability of validated simulation models allows us to address these questions by perf…”
BackgroundSelf-citationAlternative strategies in cardiac preclinical research and new clinical trial formats
Kreutzer, F. P., Meinecke, A., Schmidt, K., Fiedler, J., & Thum, T. (2022) · Cardiovascular Research · doi:10.1093/cvr/cvab075 · Cited by 36
Hettiarachchi, C., Malagutti, N., Nolan, C. J., Suominen, H., & Daskalaki, E. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105839 · Cited by 36
Robust PBPK/PD-Based Model Predictive Control of Blood Glucose
Schaller, S., Lippert, J., Schaupp, L. A., Pieber, T. R., Schuppert, A., & Eißing, T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2497273 · Cited by 36
“Federal Drug Administration as a replacement for animal testing of glucose controllers [29].”
BackgroundMethodA Simple Robust Method for Estimating the Glucose Rate of Appearance from Mixed Meals
Herrero, P., Bondía, J., Palerm, C. C., Vehí, J., Georgiou, P., Oliver, N. S., & Toumazou, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600119 · Cited by 36
“By replacing Equation (3) into Equation (4), ∫T 0 ⎛ ⎜ ⎝ Ġ(t) + [SG + X(t)]G(t) – SGGb ⎛ ⎜ ⎝ Vdt = fD (5) Defining I’(t) as [I(t) – Ib], Equation (2) becomes Ẋ(t) = –p2X(t) + p2SII’(t) (6) which, by applying the Laplace transform, can be expressed as X(s) I’(s) = SI p2 s + p2 (7) The impulse response of Equation (7) is…”
MethodInfluentialA Gain-Scheduling Model Predictive Controller for Blood Glucose Control in Type 1 Diabetes
Abu-Rmileh, A., & García-Gabín, W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033663 · Cited by 37
“while providing realistic results and covering a wider range of the variability observed among diabetic population [7].”
BackgroundMethodInfluentialControl-oriented physiological modeling of hemodynamic responses to blood volume perturbation
Bighamian, R., Parvinian, B., Scully, C. G., Kramer, G. C., & Hahn, J. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.01.008 · Cited by 37
Khodakaramzadeh, S., Batmani, Y., & Meskin, N. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101603 · Cited by 36
Modeling impulsive insulin delivery in insulin pump with time delays
Song, X., Huang, M., & Li, J. (2014) · SIAM Journal on Applied Mathematics · doi:10.1137/130933137 · Cited by 35
“A number of mathematical models and algorithms have been developed for the artificial pancreas ([17], [20], [25], [45], [47], [46], [48], and the references therein).”
BackgroundMethodMathematical model of glucose–insulin homeostasis in healthy rats
Lombarte, M., Lupo, M., Campetelli, G., BASUALDO, M. S., & Rigalli, A. (2013) · Mathematical Biosciences · doi:10.1016/j.mbs.2013.07.017 · Cited by 35
Assessment of Blood Glucose Predictors: The Prediction-Error Grid Analysis
Sampath, S., Naumova, V., Man, C. D., Facchinetti, A., Renard, É., Cobelli, C., & Pereverzev, S. V. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0033 · Cited by 35
“We perform our reliability and robustness tests with data of 10 virtual subjects provided by the Padova/University of Virginia simulator.(12) Data of the first three subjects (Virtual ID 1, 2, and 3) have been randomly chosen from 100 traces generated by the simulator.”
Self-citationTowards Safe Policy Improvement for Non-Stationary MDPsPreprint
Chandak, Y., Jordan, S. M., Theocharous, G., White, M., & Thomas, P. S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2010.12645 · Cited by 34
“Non-Stationary Diabetes Treatment: This environment is based on an open-source implementation [68] of the FDA approved Type-1 Diabetes Mellitus simulator (T1DMS) [44, 37] for treatment of Type-1 diabetes.”
Artificial Intelligence for In Silico Clinical Trials: A ReviewPreprint
Wang, Z., Gao, C., Glass, L. M., & Sun, J. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2209.09023 · Cited by 35
“Other relevant works on artificial pancreas include an FDA-approved computer simulation of glucose sensing, and insulin delivery [23], improvements on existing simulators [24], and improvements on the control algorithm using modern ML methods like reinforcement learning [31].”
BackgroundHughes, J., Gautier, T., Colmegna, P., Fabris, C., & Breton, M. D. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820973193 · Cited by 34
“ Q t k k Q t u t q q m 1 1 1 12 ( ) = − + ( ) + ( ) ( ) (3)”
Self-citationA coordinated control strategy for insulin and glucagon delivery in type 1 diabetes
Herrero, P., Bondía, J., Oliver, N. S., & Georgiou, P. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1378352 · Cited by 34
Hybrid Knowledge and Data Driven Synthesis of Runtime Monitors for Cyber-Physical Systems
Zhou, X., Ahmed, B., Aylor, J. H., Asare, P., & Alemzadeh, H. (2023) · IEEE Transactions on Dependable and Secure Computing · doi:10.1109/tdsc.2023.3242653 · Cited by 35
“The state-of-the-art UVA-Padova Type 1 Diabetes Simulator S2013 (T1DS2013) contains 30 virtual patients, which were demonstrated to be representative of the T1DM population observed in a clinical trial [65], and has been approved by the FDA for pre-clinical testing of APS [63], [66].”
BackgroundAdaptive Calibration Algorithm for Plasma Glucose Estimation in Continuous Glucose Monitoring
Barceló-Rico, F., Díez, J.-L., Rossetti, P., Vehí, J., & Bondía, J. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2253325 · Cited by 34
Modeling of Diabetes and Its Clinical Impact
Fritzen, K., Heinemann, L., & Schnell, O. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818785642 · Cited by 34
Open source automated insulin delivery: addressing the challenge
Oliver, N. S., Reddy, M., Marriott, C., Walker, T. C., & Heinemann, L. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0202-1 · Cited by 34
González, A. H., Rivadeneira, P. S., Ferramosca, A., Magdelaine, N., & Moog, C. H. (2020) · Optimal Control Applications and Methods · doi:10.1002/oca.2647 · Cited by 34
Advances and Computational Tools towards Predictable Design in Biological Engineering
Pasotti, L., & Zucca, S. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/369681 · Cited by 33
“Some mathematical models of biological/physiological systems have also been approved by the US Food and Drug Administration (FDA) for use in simulated clinical trials, thus enabling researchers, for example, to support or even skip expensive in vivo trials [26].”
BackgroundSanz, A. J. L., Doyle, F. J., & Dassau, E. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816680632 · Cited by 32
Copp, D. A., Gondhalekar, R., & Hespanha, J. P. (2017) · Optimal Control Applications and Methods · doi:10.1002/oca.2388 · Cited by 32
“The efficacy of this combined MPC/MHE estimation and control approach is demonstrated via in-silico trials of 10 virtual subjects using the commercially available UVA/Padova USFDA accepted metabolic simulator.31 While we do not present formal stability proofs for either approach in this work, we note that all simulati…”
MethodInfluentialAutomatic Artificial Pancreas Systems Using an Intelligent Multiple-Model PID Strategy
Batmani, Y., Khodakaramzadeh, S., & Moradi, P. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3116376 · Cited by 31
Viroonluecha, P., Egea-López, E., & Santa, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274608 · Cited by 31
Yu, X., Yang, Z., Sun, X., Liu, H., Li, H., Lu, J., Zhou, J. H., & Çınar, A. (2025) · AI · doi:10.3390/ai6050087 · Cited by 31
“While the simulator may not adequately capture inter-patient differences or changes in the glucose regulatory system over time, its successful use as an FDA-approved alternative to animal testing, UVa/Padova simulator [110], is a non-trivial achievement [48].”
Gondhalekar, R., Dassau, E., & Doyle, F. J. (2014) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2014.6859247 · Cited by 30
Laxminarayan, S., Reifman, J., & Steil, G. M. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600621 · Cited by 30
“001] or without [262 (12) versus 284 (14) mg/dl; p < .”
Astillo, P. V., Choudhary, G., Duguma, D. G., Kim, J., & You, I. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3063173 · Cited by 30
Model-Free Intelligent Diabetes Management Using Machine Learning
Bastani, M. (2014) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r34q7qx0s · Cited by 30
A multi-scale digital twin for adiposity-driven insulin resistance in humans: diet and drug effects
Herrgårdh, T., Simonsson, C., Ekstedt, M., Lundberg, P., Stenkula, K. G., Nyman, E., Gennemark, P., & Cedersund, G. (2023) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-023-01223-6 · Cited by 29
Intensive Insulin Therapy in Patients with Type 1 Diabetes Mellitus
Switzer, S., Moser, E. G., Rockler, B. E., & Garg, S. K. (2012) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2011.12.001 · Cited by 29
Regenerative orthopaedics: in vitro, in vivo … in silico
Geris, L. (2014) · International Orthopaedics · doi:10.1007/s00264-014-2419-6 · Cited by 29
“In diabetes, the US Food and Drug Administration (FDA) has approved the use of computational models as valid preclinical evidence for the dossier of implantable insulin pumps [66].”
BackgroundNormal-only Anomaly detection in environmental sensors in CPS: A comprehensive review
Acquaah, Y. T., & Roy, K. (2024) · IEEE Access · doi:10.1109/access.2024.3513714 · Cited by 29
“Zhao and Fu [104] presented a statistical analysis-based failure detection method, where a high-level glucose monitoring tool detects sensor problems solely using continuous glucose monitoring (CGM) data [105].”
Network and systems biology: essential steps in virtualising drug discovery and development
Wierling, C., Keßler, T., Ogilvie, L. A., Lange, B. M. H., Yaspo, M., & Lehrach, H. (2015) · Drug Discovery Today Technologies · doi:10.1016/j.ddtec.2015.07.002 · Cited by 28
Automatic Bolus and Adaptive Basal Algorithm for the Artificial Pancreatic β-Cell
Wang, Y., Dassau, E., Zisser, H., Jovanovic, L. G., & Doyle, F. J. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0029 · Cited by 28
“22 These subjects are based on a clinical study using tracers conducted by Toffolo et al. 28 The underlying assumption in the metabolic simulator is that the 100 subjects can represent the range of the T1DM population.”
Revert, A., Calm, R., Vehí, J., & Bondía, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2058805 · Cited by 28
Automatic Adaptation of Basal Insulin Using Sensor-Augmented Pump Therapy
Herrero, P., Bondía, J., Giménez, M., Oliver, N. S., & Georgiou, P. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818761752 · Cited by 28
A review on control-relevant glucose–insulin dynamics models and regulation strategies
Bhonsle, S., & Saxena, S. (2019) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651819870328 · Cited by 28
Galvanin, F., Barolo, M., Macchietto, S., & Bezzo, F. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0717-8 · Cited by 28
Steil, G. M., Hipszer, B., & Reifman, J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400334 · Cited by 27
“[2] Typically is within 15% if the subject has accurately administered insulin for all meals during the previous day and not eaten for 10 h.”
BackgroundInfluentialPagkalos, I., Herrero, P., Toumazou, C., & Georgiou, P. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2301377 · Cited by 28
“To carry out such comparison, the FDA-accepted UVa-Padova T1DM simulator [15] was employed.”
MethodInfluentialSymbolic Control Design of an Artificial Pancreas for Type-2 Diabetes
Borri, A., Pola, G., Pepe, P., Benedetto, M. D. D., & Palumbo, P. J. (2021) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2021.3135320 · Cited by 27
“We now consider a population of 10 000 type-2 diabetic VPs, each represented by an extended high-dimensional VP model [41], [46], which well describes both type-1 and type-2 diabetic patients and constitutes the core of the UVA/Padova Type-1 Diabetes Simulator, approved by the FDA as a substitute to animal trials in t…”
BackgroundLu, S., Naumova, V., & Pereverzev, S. V. (2012) · Journal of Inverse and Ill-Posed Problems · doi:10.1515/jip-2012-0050 · Cited by 27
“To illustrate how these predictors work we use data set of 100 virtual subjects which are obtained from Padova/University of Virginia simulator [10].”
MethodClinically Accurate Prediction of Glucose Levels in Patients with Type 1 Diabetes
Amar, Y., Shilo, S., Oron, T., Amar, E., Phillip, M., & Segal, E. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0435 · Cited by 27
“In addition to the real-life data acquired, we also trained and tested the computational models on data generated by the distributed version of the UVA/Padova T1DM simulator, which include in silico data of 30 simulated T1DM patients (10 adults, 10 adolescents, and 10 children).(15) This simulator was accepted in 2008…”
A clinical review of the t:slim X2 insulin pump
Berget, C., Lange, S. L., Messer, L. H., & Forlenza, G. P. (2020) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2020.1814734 · Cited by 27
El Páncreas Artificial: Control Automático de Infusión de Insulina en Diabetes Mellitus Tipo 1
Bondía, J., Vehí, J., Palerm, C. C., & Herrero, P. (2010) · Revista Iberoamericana de Automática e Informática Industrial RIAI · doi:10.1016/s1697-7912(10)70021-2 · Cited by 27
Mathematical Modeling of the Blood Glucose Regulation System in Diabetes Mellitus Patients
Александрович, К. В., Philippov, Y. I., Tarasov, Y. V., Boyarsky, M. D., Mayorov, A. Y., Shestakova, M. V., & Dedov, I. I. (2015) · Annals of the Russian academy of medical sciences · doi:10.15690/vramn.v70.i5.1441 · Cited by 27
“Схема математической модели системы инсулин–глюкоза, лежащей в основе симулятора UVA / PADOVA (адаптировано из [72, 73]).”
InfluentialAlbers, D. J., Hripcsak, G. M., & Schmidt, J. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048058 · Cited by 26
“For example, recently an endocrine model of the type 1 diabetes, being used in the context of developing an artificial pancreas [36], has been approved by the FDA as a substitute for animal trials for preclinical trials [41] [39] [40].”
MethodZhou, T., Dickson, J. L., Shaw, G. M., & Chase, J. G. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817738791 · Cited by 26
Yousefi, M., van Heusden, K., West, N., Mitchell, I. M., Ansermino, J. M., & Dumont, G. A. (2018) · Control Engineering Practice · doi:10.1016/j.conengprac.2018.11.009 · Cited by 26
Mapping data to virtual patients in type 1 diabetes
Colmegna, P. H., Wang, K., Garcia‐Tirado, J., & Breton, M. D. (2020) · Control Engineering Practice · doi:10.1016/j.conengprac.2020.104605 · Cited by 26
Self-citationModeling of Testosterone Regulation by Pulse-Modulated Feedback
Mattsson, P., & Medvedev, A. V. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-10984-8_2 · Cited by 26
Turksoy, K., Bayrak, E. S., Quinn, L., Littlejohn, E., & Çınar, A. (2013) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2013.6580275 · Cited by 26
A Spatially Continuous Model of Carbohydrate Digestion and Transport Processes in the Colon
Moorthy, A. S., Brooks, S. P. J., Kalmokoff, M. L., & Eberl, H. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0145309 · Cited by 26
“Mathematical models currently used in investigating properties of colon function provide a similar level of abstraction as in vitromodels, greatly simplifying the geometric/physical representation of the colon and often focusing on the microbiology of the anaerobic digestion processes that occur [17, 18], or as proof-…”
MethodZhao, C., Sun, Y., & Zhao, L. (2013) · AIChE Journal · doi:10.1002/aic.14176 · Cited by 25
Loutseiko, M., Voskanyan, G. R., Keenan, D. B., & Steil, G. M. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500605 · Cited by 25
Evaluating Glycemic Control Algorithms by Computer Simulations
Wilinska, M. E., Bláha, J., Chassin, L. J., Cordingley, J. J., Dormand, N. C., Ellmerer, M., Haluzík, M., Plank, J., Vlasselaers, D., Wouters, P. J., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0016 · Cited by 25
A simple modeling framework for prediction in the human glucose–insulin system
Sirlanci, M., Levine, M. E., Wang, C. C. L., Albers, D. J., & Stuart, A. M. (2023) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0146808 · Cited by 25
“In all these works and many others, [26, 27, 49, 79], that are focused on closed-loop-control of BG levels of T1DM patients, the amount of insulin to be infused via a pump is decided based on mainly the CGM.”
BackgroundA Novel Adaptive Basal Therapy Based on the Value and Rate of Change of Blood Glucose
Wang, Y., Percival, M. W., Dassau, E., Zisser, H., Jovanovic, L. G., & Doyle, F. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300513 · Cited by 25
Geris, L., Guyot, Y., Schrooten, J., & Papantoniou, I. (2016) · Interface Focus · doi:10.1098/rsfs.2015.0105 · Cited by 25
A comparison among three maximal mathematical models of the glucose-insulin system
Pompa, M., Panunzi, S., Borri, A., & De Gaetano, A. (2021) · PLOS ONE · doi:10.1371/journal.pone.0257789 · Cited by 24
Goodwin, G. C., Seron, M. M., Medioli, A. M., Smith, T. A., King, B. R., & Smart, C. E. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101813 · Cited by 24
Zone-MPC Automated Insulin Delivery Algorithm Tuned for Pregnancy Complicated by Type 1 Diabetes
Özaslan, B., Deshpande, S., Doyle, F. J., & Dassau, E. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.768639 · Cited by 24
“The simulations for each scenario are repeated ten times per subject to produce variability through random CGM noise (33) and hence, the CGM readings received by the controller are noisy.”
BackgroundIntelligent Control with Artificial Neural Networks for Automated Insulin Delivery Systems
de Farias, J. L. C. B., & Bessa, W. M. (2022) · Bioengineering · doi:10.3390/bioengineering9110664 · Cited by 24
“MPC has been extensively used [6–9] and, when compared PID controllers, show better performance [10,11].”
MethodRoman, P., Natalia, P., Andrij, M., & Iryna, S. (2015) · International Conference on Experience of Designing and Applications of CAD Systems in Microelectronics · doi:10.1109/cadsm.2015.7230822 · Cited by 24
“In most models the intensity reduction of glucose depends on the concentration of insulin [5].”
BackgroundChase, J. G., Desaive, T., & Preiser, J.-C. (2016) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-319-27349-5_35 · Cited by 24
Xie, J., & Wang, Q. (2019) · Smart Health · doi:10.1016/j.smhl.2019.100069 · Cited by 25
In Silico Trial of Optimized Versus Actual Public Defibrillator Locations
Sun, C. L. F., Karlsson, L., Torp-Pedersen, C. T., Morrison, L. J., Brooks, S. C., Folke, F., & Chan, T. C. Y. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.06.075 · Cited by 24
(2018) · doi:10.1177/1932296817735341 · Cited by 23
Prediction of Blood Glucose Level Using Nonlinear System Identification Approach
Aljamaan, I. A., & Al-Naib, I. A. I. (2021) · IEEE Access · doi:10.1109/access.2021.3139578 · Cited by 23
“A more detailed formulation of different nonlinear Box-Jenkins approaches is presented in References [21], [40]–[42].”
MethodInfluentialHettiarachchi, C., Malagutti, N., Nolan, C. J., Daskalaki, E., & Suominen, H. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871054 · Cited by 23
Shedding light on grey noise in diabetes modelling
Mansell, E. J., Docherty, P. D., & Chase, J. G. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.06.007 · Cited by 23
Control-Oriented Model With Intra-Patient Variations for an Artificial Pancreas
Moscoso-Vásquez, M., Colmegna, P. H., Rosales, N., Garelli, F., & Sánchez‐Peña, R. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2969389 · Cited by 24
Cobelli, C., & Man, C. D. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211015268 · Cited by 24
Self-citationHerrgårdh, T., Li, H., Nyman, E., & Cedersund, G. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.619254 · Cited by 23
“…the insulin signaling part does not describe most of the proteins involved in the insulin signaling network (Humphrey et al., 2013), other stimuli which cross-talk with insulin signaling, such as insulin-like growth factor (De Meyts, 1994), catecholamines (Krieger and Landsberg, 1988), etc.”
BackgroundGarcía-Jaramillo, M., Calm, R., Bondía, J., & Vehí, J. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.04.003 · Cited by 23
“model was implemented in the UVa (University of Virginia) simulator [25], accepted by the US Food and Drug Administration as a substitute for animal trials in the preclinical testing of closed-loop control strategies.”
Micheletto, F., Man, C. D., Kolterman, O., Chiquette, E., Herrmann, K., Schirra, J. R. J., Kovatchev, B. P., & Cobelli, C. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0054 · Cited by 23
“In that sense, the approach presented here is new and only possible because of recent advances in the in silico modeling of insulin–glucose dynamics in diabetes.(3,10) The availability of data from sophisticated tracer studies(26,27) allowed the reconstruction of the effects of pramlintide on the glucose rate of appea…”
BackgroundMethodSelf-citationSchiavon, M., Man, C. D., & Cobelli, C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0248 · Cited by 23
Self-citationAllam, F., Nossair, Z., Gomma, H. W., Ibrahim, I., & Abdelsalam, M. (2012) · International Journal of Intelligent Systems and Applications · doi:10.5815/ijisa.2012.10.07 · Cited by 23
Pretty, C. G. (2012) · UC Research Repository (University of Canterbury) · doi:10.26021/2015 · Cited by 23
Clinical impact of blood glucose monitoring accuracy: an in-silico study
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710474 · Cited by 22
“In this study, we aim to quantify the clinical impact of BG monitoring system accuracy using the latest UVA/Padova simulation platform by (1) constructing models that replicate the characteristics of commercially available BG monitoring systems, (2) modeling type 1 subject behavior related to meals and self-treatment,…”
BackgroundMethodSelf-citationO’Leary, D., Zaheer, A., Redmond, H. P., & Corrigan, M. A. (2016) · mHealth · doi:10.21037/mhealth.2016.09.02 · Cited by 22
“Although the intention is not to completely replace actual clinical trials involving real patients, in silico trials have the potential to reduce the number of patients required to perform a clinical trial as well as limiting the exposure of to adverse effects of trial medications (45).”
BackgroundCescon, M., Deshpande, S., Nimri, R., Doyle, F. J., & Dassau, E. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3005622 · Cited by 22
“insulin in plasma and its degradation in the liver and periphery, for each type of insulin, as a chain of two compartments [21] and propose that the total plasma insulin concentration I(t) [pmol/l]”
BackgroundMethodInfluentialAbbes, I. B., Richard, P.-Y., Lefebvre, M.-A., Guilhem, I., & Poirier, J.-Y. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700315 · Cited by 22
GoCARB in the Context of an Artificial Pancreas
Agianniotis, A., Anthimopoulos, M., Daskalaki, E., Drapela, A., Stettler, C., Diem, P., & Mougiakakou, S. G. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815583333 · Cited by 22
“To this end, we used a population of 10 adult T1D patients provided by the Food and Drug Administration accepted University of Virginia T1D simulator.(21) This group of patients was considered to be either on OL, simulating the standard treatment in which BR and IC ratio were defined by the treating physician, or on C…”
Method
Metadata
- Authors
- Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C.
- Affiliations
- University of Virginia (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- University of Padua (IT)
- Corresponding author
- Kovatchev, Boris P.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-01
- Volume
- 3
- Issue
- 1
- Pages
- 44-55
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2681269
- OpenAlex
- W2167160009
- Semantic Scholar
- 98207f5f90ddab161fa26eb0ed21911b4960fc86
- Cited by
- 760
- References
- 49
- Citations by year
- 2026: 26 · 2025: 23 · 2024: 29 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 50 · 2019: 55 · 2018: 54 · 2017: 51 · 2016: 48 · 2015: 48 · 2014: 64 · 2013: 66 · 2012: 49
- Type
- conference abstract
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01-DK-051562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, feedback control, artificial pancreas, continuous glucose monitoring, subcutaneous insulin administration, insulin pump, control algorithm simulation, meal challenge, glycemic variability
- MeSH terms
- Adolescent, Adult, Algorithms, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Drug Evaluation, Preclinical, Glucose, Humans, Insulin Infusion Systems, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.