The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Glucose Clamp Algorithms and Insulin Time-Action Profiles
Open accessAbstract
Motivation: Most current insulin pumps include an insulin-on-board (IOB) feature to help subjects avoid problems associated with “insulin stacking.” In addition, many control algorithms proposed for a closed-loop artificial pancreas make use of IOB to reduce the probability of hypoglycemic events that often occur due to the integral action of the controller. The IOB curves are generated from the pharmacodynamic (time-activity profiles) actions of subcutaneous insulin, which are obtained from glycemic clamp studies. Methods: Glycemic clamp algorithms are reviewed and in silico studies are performed to analyze the effect of glucose meter bias and noise on glycemic control and the manipulated glucose infusion rates. The glucose infusion rates are used to obtain insulin time-activity profiles, which are then used to generate IOB curves. Results: A model-based, three-step-ahead controller is shown to be equivalent to a proportional-integral control algorithm with time-delay compensation. A systematic glucose meter bias of +6 mg/dl results in a decrease in the glucose area under the curve of 3% but no change in the IOB profiles. Conclusions: Based on these preliminary simulation studies, a substantial amount of glucose meter bias and noise during a glycemic clamp can be tolerated with little net effect on the IOB curves. It is suggested that handheld glucose meters can therefore be used in clamp studies if the measurements are filtered (averaged) before processing by the control algorithm. Clinical studies are needed to confirm these preliminary results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Control engineering approaches have been applied to the glucose–insulin closed-loop system [99]”
From Health behavior models in the age of mobile interventions: are our theories up to the task? (2011) · cites this paper as [99]
Citations
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Process Control: Modeling, Design and Simulation
Bequette, B. W. (2002) · Medical Entomology and Zoology · Cited by 815
Self-citationAn Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Clinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
Insulin Control of Glucose Metabolism in Man
Insel, P. A., Liljenquist, J. E., Tobin, J. D., Sherwin, R. S., Watkins, P., Andres, R., & Berman, M. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108006 · Cited by 244
Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting Insulin
Wilinska, M. E., Chassin, L. J., Schaller, H. C., Schaupp, L., Pieber, T. R., & Hovorka, R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839639 · Cited by 237
Ellingsen, C., Dassau, E., Zisser, H., Grosman, B., Percival, M. W., Jovanovic, L. G., & Doyle, F. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300319 · Cited by 174
Research works printed but not linked: 7
- Lee H, 2009, J Diabetes Sci Technol., 3, A101
- Walsh J, 2006, Pumping insulin.
- Heinemann L, 2004, Time-action profiles of insulin preparations
- DeFronzo RA, 1979, Am J Physiol., 237, E214
- Clemens AH, 1979, Med Prog Technol., 6, 91
- Bergman RN, 1979, Am J Physiol., 236, E667
- Lee H, Biomed Signal Process Control.
Cited by
Health behavior models in the age of mobile interventions: are our theories up to the task?
Riley, W. T., Rivera, D. E., Atienza, A. A., Nilsen, W., Allison, S. M., & Mermelstein, R. (2011) · Translational Behavioral Medicine · doi:10.1007/s13142-011-0021-7 · Cited by 978
Insulin Stacking Versus Therapeutic Accumulation: Understanding the Differences
Heise, T., & Meneghini, L. F. (2014) · Endocrine Practice · doi:10.4158/ep13090.ra · Cited by 87
Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs)
Howsmon, D., Cameron, F., Baysal, N., Ly, T., Forlenza, G., Maahs, D., Buckingham, B., Hahn, J., & Bequette, B. (2017) · Sensors · doi:10.3390/s17010161 · Cited by 27
Self-citationResalat, N., Youssef, J. E., Reddy, R., & Jacobs, P. G. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2270 · Cited by 15
Metadata
- Authors
- Bequette, B. W.
- Affiliations
- Rensselaer Polytechnic Institute (US)
- Corresponding author
- Bequette, B. Wayne
- ORCID
- Bequette, B. Wayne
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-09
- Volume
- 3
- Issue
- 5
- Pages
- 1005-1013
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769898
- OpenAlex
- W14770939
- Cited by
- 43
- References
- 25
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 5 · 2012: 3
- Type
- conference abstract
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
- Keywords
- insulin on board, glucose infusion rate, PI controller, time delay compensation, hypoglycemia
- MeSH terms
- Algorithms, Blood Glucose, Computer Simulation, Diabetes Mellitus, Equipment Design, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Models, Biological, Predictive Value of Tests, Reproducibility of Results, Glucose Clamp Technique, Pancreas, Artificial, Diagnostic Equipment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose Clamp Algorithms and Insulin Time-Action Profiles. https://app.cochat.ai/papers/10.1177/193229680900300503
- The paper
- Bequette, B. W. (2009). Glucose Clamp Algorithms and Insulin Time-Action Profiles. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300503
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.