Glucose Clamp Algorithms and Insulin Time-Action Profiles

Open access
Bequette, B. Wayne · 2009 · Journal of Diabetes Science and Technology

Abstract

Motivation: Most current insulin pumps include an insulin-on-board (IOB) feature to help subjects avoid problems associated with “insulin stacking.” In addition, many control algorithms proposed for a closed-loop artificial pancreas make use of IOB to reduce the probability of hypoglycemic events that often occur due to the integral action of the controller. The IOB curves are generated from the pharmacodynamic (time-activity profiles) actions of subcutaneous insulin, which are obtained from glycemic clamp studies. Methods: Glycemic clamp algorithms are reviewed and in silico studies are performed to analyze the effect of glucose meter bias and noise on glycemic control and the manipulated glucose infusion rates. The glucose infusion rates are used to obtain insulin time-activity profiles, which are then used to generate IOB curves. Results: A model-based, three-step-ahead controller is shown to be equivalent to a proportional-integral control algorithm with time-delay compensation. A systematic glucose meter bias of +6 mg/dl results in a decrease in the glucose area under the curve of 3% but no change in the IOB profiles. Conclusions: Based on these preliminary simulation studies, a substantial amount of glucose meter bias and noise during a glycemic clamp can be tolerated with little net effect on the IOB curves. It is suggested that handheld glucose meters can therefore be used in clamp studies if the measurements are filtered (averaged) before processing by the control algorithm. Clinical studies are needed to confirm these preliminary results.

Overview

Integrity signals

Registry

Crossref · 10.1177/193229680900300503

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 25 references

Research works printed but not linked: 7

  1. Lee H, 2009, J Diabetes Sci Technol., 3, A101
  2. Walsh J, 2006, Pumping insulin.
  3. Heinemann L, 2004, Time-action profiles of insulin preparations
  4. DeFronzo RA, 1979, Am J Physiol., 237, E214
  5. Clemens AH, 1979, Med Prog Technol., 6, 91
  6. Bergman RN, 1979, Am J Physiol., 236, E667
  7. Lee H, Biomed Signal Process Control.

Cited by

See all 43

Metadata

Authors
Bequette, B. W.
Affiliations
Rensselaer Polytechnic Institute (US)
Corresponding author
Bequette, B. Wayne
Venue
Journal of Diabetes Science and Technology
Published
2009-09
Volume
3
Issue
5
Pages
1005-1013
ISSN
1932-2968 (ISSN-L)
OpenAlex
W14770939
Cited by
43
References
25
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 5 · 2012: 3
Type
conference abstract
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
Keywords
insulin on board, glucose infusion rate, PI controller, time delay compensation, hypoglycemia
MeSH terms
Algorithms, Blood Glucose, Computer Simulation, Diabetes Mellitus, Equipment Design, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Models, Biological, Predictive Value of Tests, Reproducibility of Results, Glucose Clamp Technique, Pancreas, Artificial, Diagnostic Equipment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glucose Clamp Algorithms and Insulin Time-Action Profiles. https://app.cochat.ai/papers/10.1177/193229680900300503
The paper
Bequette, B. W. (2009). Glucose Clamp Algorithms and Insulin Time-Action Profiles. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.