Zone Model Predictive Control: A Strategy to Minimize Hyper- and Hypoglycemic Events
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Development of an artificial pancreas based on an automatic closed-loop algorithm that uses a subcutaneous insulin pump and continuous glucose sensor is a goal for biomedical engineering research. However, closing the loop for the artificial pancreas still presents many challenges, including model identification and design of a control algorithm that will keep the type 1 diabetes mellitus subject in normoglycemia for the longest duration and under maximal safety considerations. Method: An artificial pancreatic β-cell based on zone model predictive control (zone-MPC) that is tuned automatically has been evaluated on the University of Virginia/University of Padova Food and Drug Administration-accepted metabolic simulator. Zone-MPC is applied when a fixed set point is not defined and the control variable objective can be expressed as a zone. Because euglycemia is usually defined as a range, zone-MPC is a natural control strategy for the artificial pancreatic β-cell. Clinical data usually include discrete information about insulin delivery and meals, which can be used to generate personalized models. It is argued that mapping clinical insulin administration and meal history through two different second-order transfer functions improves the identification accuracy of these models. Moreover, using mapped insulin as an additional state in zone-MPC enriches information about past control moves, thereby reducing the probability of overdosing. In this study, zone-MPC is tested in three different modes using unannounced and announced meals at their nominal value and with 40% uncertainty. Ten adult in silico subjects were evaluated following a scenario of mixed meals with 75, 75, and 50 grams of carbohydrates (CHOs) consumed at 7 am, 1 pm, and 8 pm, respectively. Zone-MPC results are compared to those of the “optimal” open-loop preadjusted treatment. Results: Zone-MPC succeeds in maintaining glycemic responses closer to euglycemia compared to the “optimal” open-loop treatment in te three different modes with and without meal announcement. In the face of meal uncertainty, announced zone-MPC presented only marginally improved results over unannounced zone-MPC. When considering user error in CHO estimation and the need to interact with the system, unannounced zone-MPC is an appealing alternative. Conclusions: Zone-MPC reduces the variability of control moves over fixed set point control without the need to detune the controller. This strategy gives zone-MPC the ability to act quickly when needed and reduce unnecessary control moves in the euglycemic range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
Model predictive control: Theory and practice—A survey
García, C. E., Prett, D. M., & Morari, M. (1989) · Automatica · doi:10.1016/0005-1098(89)90002-2 · Cited by 5,284 · cited 2×
“ Sg β1βq1 ⎣ ⎦ ( ) = 0, where Sg x ( ) is defined by Equation (7).”
BackgroundA survey of industrial model predictive control technology
Qin, S. J., & Badgwell, T. A. (2003) · Control Engineering Practice · doi:10.1016/s0967-0661(02)00186-7 · Cited by 5,099
Predictive Control With Constraints
Maciejowski, J. M. (2001) · Cambridge University Engineering Department Publications Database · Cited by 4,368
Predictive control with constraints
Camacho, E. F. (2003) · Automatica · doi:10.1016/s0005-1098(03)00056-6 · Cited by 3,530
Dynamic matrix control¿A computer control algorithm
Cutler, C. R., & Ramaker, B. L. (1980) · IEEE Transactions on Automatic Control · doi:10.1109/jacc.1980.4232009 · Cited by 1,835 · cited 1×
“yk + j range = [yk + j lower -lower bound, yk + j upper − upper bound] (9)”
BackgroundNonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · cited 2×
“In all MPC experiments, the weight upon predicted outputs, Q, is set to 1, while the weight upon future CM, R, is set automatically by Equation (14).”
BackgroundMarlin, T. E. (1995) · Medical Entomology and Zoology · Cited by 1,042
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500 · cited 1×
“1 for all yk + j > upper bound j = 1, P 0 for all yk + j ≤ upper bound j = 1, P 2 ⎨ ⎩ (11)”
Self-citationHovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450 · cited 4×
“In order to generate a prediction using Equation (12), we need p past measurements of G and d1 + q1 and d2 + q2 past insulin and meal measurements, respectively.”
BackgroundMethodInfluentialProcess control: Designing processes and control systems for dynamic performance
Barton, G. (1996) · Journal of Process Control · doi:10.1016/s0959-1524(96)90017-7 · Cited by 434
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403 · cited 3×
“An alternative formulation of the model, which provides a full reliable input memory to the system, is described in Equation (13):”
BackgroundMethodAn Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313 · cited 4×
“Mmap (s) = 1 (10s + 1)(45s + 1) M(s) (5)”
BackgroundMethodInfluentialPfeiffer, E., Thum, C., & Clemens, A. (1974) · Hormone and Metabolic Research · doi:10.1055/s-0028-1093841 · Cited by 238 · cited 1×
“For example, Equation (3) describes the connection between predicted output ŷ at instant k and past p and q output and input records, respectively.”
BackgroundClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Ellingsen, C., Dassau, E., Zisser, H., Grosman, B., Percival, M. W., Jovanovič, L., & Doyle, F. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300319 · Cited by 153
Self-citationLee, H., & Bequette, B. W. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.03.002 · Cited by 115
Quest for the Artificial Pancreas: Combining Technology with Treatment
Harvey, R. A., Wang, Y., Grosman, B., Percival, M. W., Bevier, W. C., Finan, D. A., Zisser, H., Seborg, D. E., Jovanovič, L., Doyle, F. J., et al. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935711 · Cited by 98 · cited 2×
“This procedure is repeated for all data points in each group, and the ability to predict all groups is used as a cost function for optimization, Equation (6).”
BackgroundMethodSelf-citationControl to Range for Diabetes: Functionality and Modular Architecture
Kovatchev, B., Patek, S., Dassau, E., Doyle, F. J., Magni, L., De Nicolao, G., Cobelli, C., & Juvenile Diabetes Research Foundation Artificial Pancreas Consortium (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300509 · Cited by 83 · cited 1×
“The ST is defined by sampling times, and FIT3 h is assumed to have a value greater than 0 and lower than 1 and is calculated by Equation (15): FIT3 h = 1 − y 3 h ,k − y k k = p+1 N − PH ∑”
BackgroundSelf-citationDevelopment of the Biostator Glucose clamping algorithm.
Clemens, A. H., Hough, D. L., & D'Orazio, P. A. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.9.1899 · Cited by 49 · cited 3×
“In the presence of observed data y ∈R , where N is the number of collected data points, linear regression can be performed to establish regression vector q values by minimizing the sum squares of errors between N data records y and predicted values ŷ as it is formulated in Equation (4).”
MethodInfluentialSkyler, J. S. (2012) · Springer eBooks · doi:10.1007/978-1-4614-1028-7 · Cited by 35 · cited 3×
“The solution of optimization using the objective function described by Equation (1) for a single control variable is the vector u ∈R M.”
BackgroundMethodInfluential
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
“Other recent AP reviews include Bequette (2005), Cobelli et al. (2009), Doyle, Jovanovic, and Seborg (2007), El-Youssef, Castle, and Ward (2009), Harvey et al. (2010), Hovorka (2008, 2011), Kumareswaran, Evans, and Hovorka (2009) and Cobelli, Renard, and Kovatchev (2011).”
BackgroundModular Closed-Loop Control of Diabetes
Patek, S. D., Magni, L., Dassau, E., Hughes-Karvetski, C., Toffanin, C., De Nicolao, G., Del Favero, S., Breton, M., Man, C. D., Renard, E., et al. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192930 · Cited by 180
“[20], [41], [42], [43], [44], [45], [46]) owing to its ability to account for the anticipated impact of meals and insulin in the face of significant sensor and actuation delay.”
BackgroundSelf-citationThe artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Self-citation
Metadata
- Authors
- Grosman, B., Dassau, E., Zisser, H. C., Jovanovič, L., & Doyle, F. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-07
- Volume
- 4
- Issue
- 4
- Pages
- 961-975
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2167830353
- Cited by
- 204
- References
- 24
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.