CoChat

A Closed-Loop Artificial Pancreas Based on Risk Management

Open access
Cameron, Fraser, Bequette, B. Wayne, Wilson, Darrell M., Buckingham, Bruce A., Lee, Hyunjin, Niemeyer, Günter · 2011 · Journal of Diabetes Science and Technology
Cited by 85

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Background: Control algorithms that regulate blood glucose (BG) levels in individuals with type 1 diabetes mellitus face several fundamental challenges. Two of these are the asymmetric risk of clinical complications associated with low and high glucose levels and the irreversibility of insulin action when using only insulin. Both of these nonlinearities force a controller to be more conservative when uncertainties are high. We developed a novel extended model predictive controller (EMPC) that explicitly addresses these two challenges. Method: Our extensions to model predictive control (MPC) operate in three ways. First, they explicitly minimize the combined risk of hypoglycemia and hyperglycemia. Second, they integrate the effect of prediction uncertainties into the risk. Third, they understand that future control actions will vary if measurements fall above or below predictions. Using the University of Virginia/Padova Simulator, we compared our novel controller (EMPC) against optimized versions of a proportional-integral-derivative (PID) controller, a traditional MPC, and a basal/bolus (BB) controller, as well as against published results of an independent MPC (IMPC). The BB controller was optimized retrospectively to serve as a bound on the possible performance. Results: We tuned each controller, where possible, to minimize a published blood glucose risk index (BGRI). The simulated controllers (PID/MPC/EMPC/BB) provided BGRI values of 2.99/3.05/2.51/1.27 as compared to the published IMPC BGRI value of 4.10. These correspond to 73/79/84/92% of BG values lying in the euglycemic range (70–180 mg/dl), respectively, with mean BG levels of 151/156/147/140 mg/dl. Conclusion: The EMPC strategy extends MPC to explicitly address the issues of asymmetric glycemic risk and irreversible insulin action using estimated prediction uncertainties and an explicit risk function. This controller reduces the avoidable BGRI by 56% ( p < .05) relative to a published MPC algorithm studied on a similar population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681100500226

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 85

Metadata

Authors
Cameron, F., Bequette, B. W., Wilson, D. M., Buckingham, B. A., Lee, H., & Niemeyer, G.
Venue
Journal of Diabetes Science and Technology
Published
2011-03
Volume
5
Issue
2
Pages
368-379
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2048701218
Cited by
85
References
10
FWCI
6.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Closed-Loop Artificial Pancreas Based on Risk Management. https://app.cochat.ai/papers/10.1177/193229681100500226
The paper
Cameron, F., Bequette, B. W., Wilson, D. M., Buckingham, B. A., Lee, H., & Niemeyer, G. (2011). A Closed-Loop Artificial Pancreas Based on Risk Management. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681100500226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.