CoChat

Model-Based Closed-Loop Glucose Control in Type 1 Diabetes: The DiaCon Experience

Open access
Schmidt, Signe, Boiroux, Dimitri, Duun-Henriksen, Anne Katrine, Frøssing, Laurits, Skyggebjerg, Ole, Jørgensen, John Bagterp, Poulsen, Niels Kjølstad, Madsen, Henrik, Madsbad, Sten, Nørgaard, Kirsten · 2013 · Journal of Diabetes Science and Technology
Cited by 35

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Background: To improve type 1 diabetes mellitus (T1DM) management, we developed a model predictive control (MPC) algorithm for closed-loop (CL) glucose control based on a linear second-order deterministic-stochastic model. The deterministic part of the model is specified by three patient-specific parameters: Insulin sensitivity factor, insulin action time, and basal insulin infusion rate. The stochastic part is identical for all patients but identified from data from a single patient. Results of the first clinical feasibility test of the algorithm are presented. Methods: We conducted two randomized crossover studies. Study 1 compared CL with open-loop (OL) control. Study 2 compared glucose control after CL initiation in the euglycemic (CL-Eu) and hyperglycemic (CL-Hyper) ranges, respectively. Patients were studied from 22:00–07:00 on two separate nights. Results: Each study included six T1DM patients (hemoglobin A1c 7.2% ± 0.4%). In study 1, hypoglycemic events (plasma glucose < 54 mg/dl) occurred on two OL and one CL nights. Average glucose from 22:00–07:00 was 90 mg/dl [74–146 mg/dl; median (interquartile range)] during OL and 108 mg/dl (101–128 mg/dl) during CL (determined by continuous glucose monitoring). However, median time spent in the range 70–144 mg/dl was 67.9% (3.0–73.3%) during OL and 80.8% (70.5–89.7%) during CL. In study 2, there was one episode of hypoglycemia with plasma glucose <54 mg/dl in a CL-Eu night. Mean glucose from 22:00–07:00 and time spent in the range 70–144 mg/dl were 121 mg/dl (117–133 mg/dl) and 69.0% (30.7–77.9%) in CL-Eu and 149 mg/dl (140–193 mg/dl) and 48.2% (34.9–72.5%) in CL-Hyper, respectively. Conclusions: This study suggests that our novel MPC algorithm can safely and effectively control glucose overnight, also when CL control is initiated during hyperglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681300700515

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 35

Metadata

Authors
Schmidt, S., Boiroux, D., Duun-Henriksen, A. K., Frøssing, L., Skyggebjerg, O., Jørgensen, J. B., Poulsen, N. K., Madsen, H., Madsbad, S., & Nørgaard, K.
Venue
Journal of Diabetes Science and Technology
Published
2013-09
Volume
7
Issue
5
Pages
1255-1264
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2102109202
Cited by
35
References
10
FWCI
3.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Model-Based Closed-Loop Glucose Control in Type 1 Diabetes: The DiaCon Experience. https://app.cochat.ai/papers/10.1177/193229681300700515
The paper
Schmidt, S., Boiroux, D., Duun-Henriksen, A. K., Frøssing, L., Skyggebjerg, O., Jørgensen, J. B., Poulsen, N. K., Madsen, H., Madsbad, S., & Nørgaard, K. (2013). Model-Based Closed-Loop Glucose Control in Type 1 Diabetes: The DiaCon Experience. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700515

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.