Long-term Continuous Glucose Monitor Use in Very Young Children With Type 1 Diabetes: One-Year Results From the SENCE Study
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Objectives: Achieving optimal glycemic outcomes in young children with type 1 diabetes (T1D) is challenging. This study examined the durability of continuous glucose monitoring (CGM) coupled with a family behavioral intervention (FBI) to improve glycemia. Study Design: This one-year study included an initial 26-week randomized controlled trial of CGM with FBI ( CGM+FBI) and CGM alone ( Standard-CGM) compared with blood glucose monitoring (BGM), followed by a 26-week extension phase wherein the BGM Group received the CGM+FBI ( BGM-Crossover) and both original CGM groups continued this technology. Results: Time in range (70-180 mg/dL) did not improve with CGM use (CGM+FBI: baseline 37%, 52 weeks 41%; Standard-CGM: baseline 41%, 52 weeks 44%; BGM-Crossover: 26 weeks 38%, 52 weeks 40%). All three groups sustained decreases in hypoglycemia (<70 mg/dL) with CGM use (CGM+FBI: baseline 3.4%, 52 weeks 2.0%; Standard-CGM: baseline 4.1%, 52 weeks 2.1%; BGM-Crossover: 26 weeks 4.5%, 52 weeks 1.7%, P-values <.001). Hemoglobin A1c was unchanged with CGM use (CGM+FBI: baseline 8.3%, 52 weeks 8.2%; Standard-CGM: baseline 8.2%, 52 weeks 8.0%; BGM-Crossover: 26 weeks 8.1%, 52 weeks 8.3%). Sensor use remained high (52-week study visit: CGM+FBI 91%, Standard-CGM 92%, BGM-Crossover 88%). Conclusion: Over 12 months young children with T1D using newer CGM technology sustained reductions in hypoglycemia and, in contrast to prior studies, persistently wore CGM. However, pervasive hyperglycemia remained unmitigated. This indicates an urgent need for further advances in diabetes technology, behavioral support, and diabetes management educational approaches to optimize glycemia in young children.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“children with diabetes using rtCGM showed the benefits of reducing hypoglycemia concerns and diabetes distress (38,49,58).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [58]
In the citing paper
“Data in children show that rtCGM use in young children with type 1 diabetes reduced hypoglycemia”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [58]
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationOn the adaptive control of the false discovery rate in multiple testing with independent statistics
Benjamini, Y., & Hochberg, Y. (2000) · Journal of Educational and Behavioral Statistics · doi:10.3102/10769986025001060 · Cited by 2,015
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Self-citationMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · cited 1×
“45 % Time > 250 mg/dL 27 (22, 34) 30 (19, 40) 26 (20, 37) .”
Self-citationDiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
Self-citationLaffel, L. M., Kanapka, L. G., Beck, R. W., Bergamo, K., Clements, M. A., Criego, A., DeSalvo, D. J., Goland, R., Hood, K., Liljenquist, D., et al. (2020) · JAMA · doi:10.1001/jama.2020.6940 · Cited by 443 · cited 5×
“17(4) 976 –987 © 2022 Diabetes Technology Society Article reuse guidelines: sagepub.”
BackgroundInfluentialSelf-citationPratley, R. E., Kanapka, L. G., Rickels, M. R., Ahmann, A., Aleppo, G., Beck, R., Bhargava, A., Bode, B. W., Carlson, A., Chaytor, N. S., et al. (2020) · JAMA · doi:10.1001/jama.2020.6928 · Cited by 375
Self-citationBrown, S. A., Forlenza, G. P., Bode, B. W., Pinsker, J. E., Levy, C. J., Criego, A. B., Hansen, D. W., Hirsch, I. B., Carlson, A. L., Bergenstal, R. M., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0172 · Cited by 286
Self-citation13. Children and Adolescents: Standards of Medical Care in Diabetes−2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s013 · Cited by 267
Perantie, D. C., Lim, A., Wu, J., Weaver, P., Warren, S. L., Sadler, M., White, N. H., & Hershey, T. (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00274.x · Cited by 237
Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 Diabetes
Ware, J., Allen, J. M., Boughton, C. K., Wilinska, M. E., Hartnell, S., Thankamony, A., de Beaufort, C., Schierloh, U., Fröhlich-Reiterer, E., Mader, J. K., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2111673 · Cited by 222
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204 · cited 1×
“Following successful completion of the screening period, participants were randomized to one of three groups: (1) CGM+FBI Group used the Dexcom G5 realtime CGM with standardized training and a family behavioral intervention, (2) Standard-CGM Group used the Dexcom G5 real-time CGM with standardized training without the…”
MethodSelf-citationAlterations in White Matter Structure in Young Children With Type 1 Diabetes
Barnea-Goraly, N., Raman, M., Mazaika, P., Marzelli, M., Hershey, T., Weinzimer, S. A., Aye, T., Buckingham, B., Mauras, N., White, N. H., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1388 · Cited by 166
Van Name, M. A., Hilliard, M. E., Boyle, C. T., Miller, K. M., DeSalvo, D. J., Anderson, B. J., Laffel, L. M., Woerner, S. E., DiMeglio, L. A., & Tamborlane, W. V. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12525 · Cited by 139
Self-citationBenefits and Barriers of Continuous Glucose Monitoring in Young Children with Type 1 Diabetes
Hilliard, M. E., Levy, W., Anderson, B. J., Whitehouse, A. L., Commissariat, P. V., Harrington, K. R., Laffel, L. M., Miller, K. M., Van Name, M., Tamborlane, W. V., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0142 · Cited by 134
Self-citationCOMMISSARIAT, P. V., Harrington, K. R., Whitehouse, A. L., Miller, K. M., Hilliard, M. E., Name, M. A. V., DeSalvo, D. J., Tamborlane, W. V., Anderson, B. J., DiMeglio, L. A., et al. (2019) · Pediatric Diabetes · doi:10.1111/pedi.12956 · Cited by 132
Self-citationNeuroanatomical Correlates of Dysglycemia in Young Children With Type 1 Diabetes
Marzelli, M. J., Mazaika, P. K., Barnea-Goraly, N., Hershey, T., Tsalikian, E., Tamborlane, W., Mauras, N., White, N. H., Buckingham, B., Beck, R. W., et al. (2014) · Diabetes · doi:10.2337/db13-0179 · Cited by 131
Self-citationStrategies to Enhance New CGM Use in Early Childhood (SENCE) Study Group, Laffel, L., Harrington, K., Hanono, A., Naik, N., Ambler-Osborn, L., Schultz, A., DiMeglio, L., Woerne, S., Jolivette, H., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1060 · Cited by 95
Self-citationVariations in Brain Volume and Growth in Young Children With Type 1 Diabetes
Mazaika, P. K., Weinzimer, S. A., Mauras, N., Buckingham, B., White, N. H., Tsalikian, E., Hershey, T., Cato, A., Aye, T., Fox, L., et al. (2016) · Diabetes · doi:10.2337/db15-1242 · Cited by 85
Self-citationTsalikian, E., Fox, L., Weinzimer, S., Buckingham, B., White, N. H., Beck, R., Kollman, C., Xing, D., Ruedy, K., & Diabetes Research in Children Network (DirecNet) Study Group (2012) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00837.x · Cited by 83 · cited 1×
“18 % Time > 300 mg/dL 14 (9, 19) 15 (9, 26) 14 (8, 19) .”
Forlenza, G. P., Ekhlaspour, L., DiMeglio, L. A., Fox, L. A., Rodriguez, H., Shulman, D. I., Kaiserman, K. B., Liljenquist, D. R., Shin, J., Lee, S. W., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13312 · Cited by 67
Self-citationExtended Use of the Control-IQ Closed-Loop Control System in Children With Type 1 Diabetes
Kanapka, L. G., Wadwa, R. P., Breton, M. D., Ruedy, K. J., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M. J., Jost, E., Carria, L., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1729 · Cited by 56
Self-citationPersistence of abnormalities in white matter in children with type 1 diabetes
Fox, L. A., Hershey, T. G., Mauras, N., Arbeláez, A. M., Tamborlane, W. V., Buckingham, B. A., Tsalikian, E., Englert, K., Raman, M. M., Jo, B., et al. (2018) · Diabetologia · doi:10.1007/s00125-018-4610-6 · Cited by 51
Self-citationSundberg, F., & Forsander, G. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12057 · Cited by 30 · cited 1×
“Following successful completion of the screening period, participants were randomized to one of three groups: (1) CGM+FBI Group used the Dexcom G5 realtime CGM with standardized training and a family behavioral intervention, (2) Standard-CGM Group used the Dexcom G5 real-time CGM with standardized training without the…”
MethodLongitudinal assessment of hippocampus structure in children with type 1 diabetes
Foland-Ross, L. C., Reiss, A. L., Mazaika, P. K., Mauras, N., Weinzimer, S. A., Aye, T., Tansey, M. J., White, N. H., & the Diabetes Research in Children Network (DirecNet) (2018) · Pediatric Diabetes · doi:10.1111/pedi.12683 · Cited by 30 · cited 1×
“18 % Time > 300 mg/dL 14 (9, 19) 15 (9, 26) 14 (8, 19) .”
DiMeglio, L. A., Kanapka, L. G., DeSalvo, D. J., Anderson, B. J., Harrington, K. R., Hilliard, M. E., Laffel, L. M., Tamborlane, W. V., Name, M. A. V., Wadwa, R. P., et al. (2020) · Diabetic Medicine · doi:10.1111/dme.14276 · Cited by 25 · cited 1×
“Following successful completion of the screening period, participants were randomized to one of three groups: (1) CGM+FBI Group used the Dexcom G5 realtime CGM with standardized training and a family behavioral intervention, (2) Standard-CGM Group used the Dexcom G5 real-time CGM with standardized training without the…”
MethodSelf-citationContinuous Glucose Monitoring in Healthy Children Aged 2–8 Years
Sundberg, F., & Forsander, G. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0270 · Cited by 21
Dovč, K., Name, M. A. V., Bizjan, B. J., Rusak, E., Piona, C. A., Mutlu, G. Y., Mentink, R., Frontino, G., Macedoni, M., Ferreira, S., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14607 · Cited by 21
COMMISSARIAT, P. V., Whitehouse, A. L., Hilliard, M. E., Miller, K. M., Harrington, K. R., Levy, W. L., DeSalvo, D. J., Name, M. A. V., Anderson, B. J., Tamborlane, W. V., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0497 · Cited by 15
Self-citationTansey, M., Weinzimer, S., Beck, R., Ruedy, K., Cheng, P., Tamborlane, W., Kollman, C., Mauras, N., Fox, L., Coffey, J., et al. (2013) · Diabetes Care · doi:10.2337/dc12-2021 · Cited by 14 · cited 2×
“45 % Time > 250 mg/dL 27 (22, 34) 30 (19, 40) 26 (20, 37) .”
Self-citation
Research works printed but not linked: 1
- Group DR, 1988, DCCT Protocol (Publication No PB 88-116462-AS)
Cited by
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 293
Self-citationTauschmann, M., Cardona‐Hernandez, R., DeSalvo, D. J., Hood, K. K., Лаптев, Д. Н., Olinder, A. L., Wheeler, B. J., & Smart, C. E. (2025) · Hormone Research in Paediatrics · doi:10.1159/000543156 · Cited by 83
Self-citation
Metadata
- Authors
- Van Name, M. A., Kanapka, L. G., DiMeglio, L. A., Miller, K. M., Albanese-O’Neill, A., Commissariat, P., Corathers, S. D., Harrington, K. R., Hilliard, M. E., Anderson, B. J., Kelley, J. C., Laffel, L. M., MacLeish, S. A., Nathan, B. M., Tamborlane, W. V., Wadwa, R. P., Willi, S. M., Williams, K. M., Wintergerst, K. A., Woerner, S., Wong, J. C., & DeSalvo, D. J.
- Affiliations
- Yale School of Medicine, New Haven, CT, USA
- Jaeb Center for Health Research (US)
- Riley Hospital for Children (US)
- University of Florida Health (US)
- Joslin Diabetes Center (US)
- Cincinnati Children's Hospital Medical Center (US)
- Baylor College of Medicine (US)
- Vanderbilt University Medical Center (US)
- Rainbow Babies & Children's Hospital (US)
- University of Minnesota (US)
- Yale University (US)
- University of Colorado Anschutz (US)
- Children's Hospital of Philadelphia (US)
- Columbia University (US)
- University of Louisville (US)
- University of California, San Francisco (US)
- Corresponding author
- Kanapka, Lauren G.
- ORCID
- Kanapka, Lauren G.
- DiMeglio, Linda A.
- Miller, Kellee M.
- Albanese-O’Neill, Anastasia
- Commissariat, Persis
- Corathers, Sarah D.
- Harrington, Kara R.
- Hilliard, Marisa E.
- Anderson, Barbara J.
- Kelley, Jennifer C.
- Laffel, Lori M.
- MacLeish, Sarah A.
- Nathan, Brandon M.
- Tamborlane, William V.
- Wadwa, R. Paul
- Willi, Steven M.
- Williams, Kristen M.
- Wintergerst, Kupper A.
- Wong, Jenise C.
- DeSalvo, Daniel J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2022-03-26
- Volume
- 17
- Issue
- 4
- Pages
- 976-987
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC10348002
- OpenAlex
- W4220990420
- Cited by
- 20
- References
- 31
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 4 · 2023: 6 · 2022: 1
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons-TMC (Texas Medical Center) (submittedVersion)
- IUScholarWorks (Indiana University) (submittedVersion)
- Funders
- Leona M. and Harry B. Helmsley Charitable Trust
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, continuous glucose monitoring, very young children, glycemic control, time in range, hypoglycemia, HbA1c, blood glucose monitoring, diabetes management education
- MeSH terms
- Blood Glucose, Child, Child, Preschool, Diabetes Mellitus, Type 1, Humans, Hyperglycemia, Hypoglycemia, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.