Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurate physical activity monitoring is important for cardiac patients. Novel activity monitoring devices may enable precise measurement of physical activity. This study aimed to validate Fitbit-Flex against Actigraph accelerometer for monitoring physical activity. DESIGN: A validation study with a comparative design. METHODS: Cardiac patients and family members participating in community-based exercise programs wore Fitbit-Flex and Actigraph simultaneously over four days to monitor daily step counts and minutes of moderate to vigorous physical activity (MVPA). RESULTS: Participants (N = 48) comprised 52.1% males, with a mean age of 65.6 ± 6.9 years and 58.9% had a cardiac diagnosis. Fitbit-Flex and Actigraph were significantly correlated in males, females, total participants and cardiac patients for step counts (r = .96; r = .95; r = .95; r = .95), though less so for MVPA (r = .81; r = .65, r = .74; r = .71). As step counts increased the differences between Fitbit-Flex and Actigraph also increased. Fitbit-Flex over-estimated step counts in females (556 steps/day), males (1462 steps/day) and total participants (1038 steps/day) as well as for minutes of MVPA in females (4 min/day), males (15 min/day) and total participants (10 min/day). Fitbit-Flex had high sensitivity and specificity in classifying participants who achieved the recommended physical activity guidelines. CONCLUSION: Fitbit-Flex is accurate in assessing attainment of physical activity guideline recommendations and is useful for monitoring physical activity in cardiac patients. The device does, however, slightly over-estimate step counts and MVPA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Garber, C. E., Blissmer, B., Deschenes, M. R., Franklin, B. A., Lamonte, M. J., Lee, I.-M., Nieman, D. C., & Swain, D. P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318213fefb · Cited by 9,319
Prince, S. A., Adamo, K. B., Hamel, M., Hardt, J., Connor Gorber, S., & Tremblay, M. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-56 · Cited by 3,162
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 12×
“Similarly, Ferguson et al.15 demonstrated that over two days Fitbit-Zip (intraclass correlation coefficient (ICC)¼ 0.98) and Fitbit-One (ICC¼ 0.95) had high reliability coefficients for measuring step counts.”
BackgroundMethodResultInfluentialAerobic Exercise Reduces Blood Pressure in Resistant Hypertension
Dimeo, F., Pagonas, N., Seibert, F., Arndt, R., Zidek, W., & Westhoff, T. H. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.197780 · Cited by 370
Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295 · cited 1×
“Males are commonly identified as being more physically active than females,(27,42) advanced age is a significant independent predictor of less physical activity,(43,44) and increasing BMI is associated with decreasing accuracy of activity monitor output.(44,45) However, the regression analysis results in our study did…”
ResultAdam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202 · cited 1×
“Fitbit devices were reported to be valid instruments to measure daily caloric expenditure among older adults(28) and step counts among healthy adults.(21) The devices are reported by the manufacturers to sense motion in three dimensions and to convert these readings into activity information.”
BackgroundAccuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182 · cited 1×
“However, our results are consistent with the results of previous studies which found Fitbit devices are valid for measuring step counts in healthy participants,(15,16,21,34-36) and perform better than Fuelband devices in populations diagnosed with brain and stroke injury.(37) The findings of our study also demonstrate…”
ResultTully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172
Évaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Self-citation
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[45,50,72,79,80,88-117] Thigh or wrist Discontinued 2013 Flex Fitbit”
BackgroundAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“A total of 13 studies examined Fitbit accuracy for step count in free-living conditions (20 accuracy comparisons; Multimedia Appendix 3) [36,52-63].”
BackgroundHenriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“Fitbit devices were used in 54 studies [9,13,28-79].”
MethodStraiton, N., Alharbi, M., Bauman, A., Neubeck, L., Gullick, J., Bhindi, R., & Gallagher, R. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.03.016 · Cited by 147
Self-citationTedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
Van Blarigan, E. L., Chan, H., Van Loon, K., Kenfield, S. A., Chan, J. M., Mitchell, E., Zhang, L., Paciorek, A., Joseph, G., Laffan, A., et al. (2019) · BMC Cancer · doi:10.1186/s12885-019-5427-5 · Cited by 85
Collins, J. E., Yang, H. Y., Trentadue, T. P., Gong, Y., & Losina, E. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211231 · Cited by 55
Nicholls, S. J., Nelson, M., Astley, C., Briffa, T., Brown, A., Clark, R., Colquhoun, D., Gallagher, R., Hare, D. L., Inglis, S., et al. (2020) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2020.04.007 · Cited by 43
“Advice and activity plans are available online [17,21,22], with additional support provided through telehealth [23] and use of activity trackers [24].”
Self-citationButryn, M. L., Godfrey, K. M., Martinelli, M. K., Roberts, S. R., Forman, E. M., & Zhang, F. (2020) · Obesity Science & Practice · doi:10.1002/osp4.391 · Cited by 42
“Participants also were provided with the Fitbit Flex, a physical activity sensor worn on the wrist that has established reliability and validity.(5,6) Participants could view physical activity data in the Fitbit app and were instructed to track “active minutes” (ie, bouts of moderate‐to‐vigorous physical activity) in…”
MethodMarin, T. S., Kourbelis, C., Foote, J., Newman, P., Brown, A., Daniel, M., Coffee, N. T., Nicholls, S. J., Ganesan, A., Versace, V. L., et al. (2019) · European Journal of Preventive Cardiology · doi:10.1177/2047487318805580 · Cited by 33
Herkert, C., Kraal, J. J., van Loon, E. M. A., van Hooff, M., & Kemps, H. M. C. (2019) · JMIR mHealth and uHealth · doi:10.2196/15045 · Cited by 19
Metadata
- Authors
- Alharbi, M., Bauman, A., Neubeck, L., & Gallagher, R.
- Venue
- European Journal of Preventive Cardiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-07-10
- Volume
- 23
- Issue
- 14
- Pages
- 1476-1485
- ISSN
- 2047-4873 (ISSN-L)
- 2047-4881
- OpenAlex
- W2299195106
- Cited by
- 142
- References
- 12
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.