Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Mandibular advancement devices (MADs) represent the main non-continuous positive airway pressure (non-CPAP) therapy for patients with obstructive sleep apnoea (OSA). The aim of the European Respiratory Society Task Force was to review the evidence in favour of MAD therapy. Effects of tongue-retaining devices are not included in this report. Custom-made MADs reduce apnoea/hypopnoea index (AHI) and daytime sleepiness compared with placebo devices. CPAP more effectively diminishes AHI, while increasing data suggest fairly similar outcomes in relation to symptoms and cardiovascular health from these treatments. Patients often prefer MADs to CPAP. Milder cases and patients with a proven increase in upper airway size as a result of mandibular advancement are most likely to experience treatment success with MADs. A custom-made device titrated from an initial 50% of maximum mandibular advancement has been recommended. More research is needed to define the patients who will benefit from MAD treatment compared with CPAP, in terms of the effects on sleep-disordered breathing and on other diseases related to OSA. In conclusion, MADs are recommended for patients with mild to moderate OSA (Recommendation Level A) and for those who do not tolerate CPAP. The treatment must be followed up and the device adjusted or exchanged in relation to the outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficacy of Positive Airway Pressure and Oral Appliance in Mild to Moderate Obstructive Sleep Apnea
Barnes, M., McEvoy, R. D., Banks, S., Tarquinio, N., Murray, C. G., Vowles, N., & Pierce, R. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200311-1571oc · Cited by 597
A Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Non-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Self-citationMandibular Advancement Devices in 630 Men and Women With Obstructive Sleep Apnea and Snoring
Marklund, M., Stenlund, H., & Franklin, K. A. (2004) · Chest · doi:10.1378/chest.125.4.1270 · Cited by 372
Self-citationGotsopoulos, H., Kelly, J. J., & Cistulli, P. A. (2004) · Sleep · doi:10.1093/sleep/27.5.934 · Cited by 340
Oral Appliance Therapy Improves Symptoms in Obstructive Sleep Apnea: A Randomized, Controlled Trial
Gotsopoulos, H., Chen, C., Qian, J., & Cistulli, P. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200203-208oc · Cited by 331
Engleman, H. M., McDonald, J. P., Graham, D., Lello, G. E., Kingshott, R. N., Coleman, E. L., Mackay, T. W., & Douglas, N. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109023 · Cited by 289
Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea
Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200701-114oc · Cited by 289
Self-citationTitrated mandibular advancement versus positive airway pressure for sleep apnoea
Gagnadoux, F., Fleury, B., Vielle, B., Pételle, B., Meslier, N., N’Guyen, X. L., Trzepizur, W., & Racineux, J. L. (2009) · European Respiratory Journal · doi:10.1183/09031936.00148208 · Cited by 275
Randomised study of three non-surgical treatments in mild to moderate obstructive sleep apnoea
Lam, B., Sam, K., Mok, W. Y., Cheung, M. T., Fong, D. Y., Lam, J. C., Lam, D. C., Yam, L. Y., & lp, M. S. (2007) · Thorax · doi:10.1136/thx.2006.063644 · Cited by 261
Randerath, W. J., Heise, M., Hinz, R., & Ruehle, K.-H. (2002) · Chest · doi:10.1378/chest.122.2.569 · Cited by 257
Self-citationWalker-Engström, M.-L., Tegelberg, Å., Wilhelmsson, B., & Ringqvist, I. (2002) · Chest · doi:10.1378/chest.121.3.739 · Cited by 223
A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment
BLOCH, K. E., ISELI, A., ZHANG, J. N., XIE, X., KAPLAN, V., STOECKLI, P. W., & RUSSI, E. W. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9908112 · Cited by 223
Effect of Oral Appliance Therapy on Upper Airway Collapsibility in Obstructive Sleep Apnea
Ng, A. T., Gotsopoulos, H., Qian, J., & Cistulli, P. A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200211-1275oc · Cited by 221
Liu, Y., Lowe, A. A., Orthodont, D., Fleetham, J. A., & Park, Y.-C. (2001) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1067/mod.2001.118782 · Cited by 208
Tan, Y. K. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.3.239 · Cited by 206
Walker-Engström, M.-L., Ringqvist, I., Vestling, O., Wilhelmsson, B., & Tegelberg, Å. (2003) · Sleep and Breathing · doi:10.1007/s11325-003-0119-3 · Cited by 193
Obstructive Sleep apnea Therapy
Hoekema, A., Stegenga, B., Wijkstra, P. J., van der Hoeven, J. H., Meinesz, A. F., & de Bont, L. G. M. (2008) · Journal of Dental Research · doi:10.1177/154405910808700917 · Cited by 186
Mandibular advancement appliances and obstructive sleep apnoea: a randomized clinical trial
Johnston, C. D. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.3.251 · Cited by 185
Itzhaki, S., Dorchin, H., Clark, G., Lavie, L., Lavie, P., & Pillar, G. (2007) · Chest · doi:10.1378/chest.06-0965 · Cited by 172
Prospective evaluation of an oral appliance in the treatment of obstructive sleep apnea syndrome
Blanco, J., Zamarr�n, C., Abeleira Pazos, M. T., Lamela, C., & Suarez Quintanilla, D. (2005) · Sleep and Breathing · doi:10.1007/s11325-005-0003-4 · Cited by 172
PETRI, N., SVANHOLT, P., SOLOW, B., WILDSCHIØDTZ, G., & WINKEL, P. (2008) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00645.x · Cited by 152
Trzepizur, W., Gagnadoux, F., Abraham, P., Rousseau, P., Meslier, N., Saumet, J.-L., & Racineux, J.-L. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2008.06.013 · Cited by 144
Naismith, S. L., Winter, V. R., Hickie, I. B., & Cistulli, P. A. (2005) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26365 · Cited by 140
Rose, E. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.2.191 · Cited by 132
Lawton, H. M. (2005) · The European Journal of Orthodontics · doi:10.1093/ejo/cjh067 · Cited by 127
Comparison of two dental devices for treatment of obstructive sleep apnea syndrome (OSAS)
Hans, M. G., Nelson, S., Luks, V. G., Lorkovich d, P., & Baek, S.-J. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)70293-2 · Cited by 123
Gauthier, L., Laberge, L., Beaudry, M., Laforte, M., Rompré, P. H., & Lavigne, G. J. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2008.03.011 · Cited by 115
Hoekema, A., Stegenga, B., Bakker, M., Brouwer, W. H., de Bont, L. G. M., Wijkstra, P. J., & van der Hoeven, J. H. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0093-7 · Cited by 107
A randomized prospective long‐term study of two oral appliances for sleep apnoea treatment
GHAZAL, A., SORICHTER, S., JONAS, I., & ROSE, E. C. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00738.x · Cited by 106
Oral appliance treatment of obstructive sleep apnea: an update
Chan, A. S., & Cistulli, P. A. (2009) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e3283319b12 · Cited by 103
Effects of oral appliances and CPAP on the left ventricle and natriuretic peptides
Hoekema, A., Voors, A. A., Wijkstra, P. J., Stegenga, B., van der Hoeven, J. H., Tol, C. G., & de Bont, L. G. M. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.06.016 · Cited by 81
Autonomic Cardiac Modulation in Obstructive Sleep Apnea
Coruzzi, P., Gualerzi, M., Bernkopf, E., Brambilla, L., Brambilla, V., Broia, V., Lombardi, C., & Parati, G. (2006) · Chest · doi:10.1378/chest.130.5.1362 · Cited by 65
Cited by
Obstructive sleep apnoea syndrome
Lévy, P., Kohler, M., McNicholas, W. T., Barbé, F., McEvoy, R. D., Somers, V. K., Lavie, L., & Pépin, J.-L. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.15 · Cited by 1,235
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“11,101 Although subjective adherence reports suggest short-term adherence is relatively good, 23,60,63,101 exceeding that of CPAP, the discrepancy between subjective and objective CPAP usage 4 suggests that better adherence to OA m cannot be confirmed in the absence of objective moni - toring.”
Self-citationObjective measurement of compliance during oral appliance therapy for sleep-disordered breathing
Vanderveken, O. M., Dieltjens, M., Wouters, K., De Backer, W. A., Van de Heyning, P. H., & Braem, M. J. (2013) · Thorax · doi:10.1136/thoraxjnl-2012-201900 · Cited by 297
Randerath, W., Bassetti, C. L., Bonsignore, M. R., Farre, R., Ferini-Strambi, L., Grote, L., Hedner, J., Kohler, M., Martinez-Garcia, M.-A., Mihaicuta, S., et al. (2018) · European Respiratory Journal · doi:10.1183/13993003.02616-2017 · Cited by 245
Self-citationDieltjens, M., Braem, M. J., Vroegop, A. V. M. T., Wouters, K., Verbraecken, J. A., De Backer, W. A., Van de Heyning, P. H., & Vanderveken, O. M. (2013) · Chest · doi:10.1378/chest.13-0613 · Cited by 171
Self-citation
Metadata
- Authors
- Marklund, M., Verbraecken, J., & Randerath, W.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-11-10
- Volume
- 39
- Issue
- 5
- Pages
- 1241-1247
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2140030900
- Cited by
- 239
- References
- 35
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.