The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
What the pulmonary specialist should know about the new inhalation therapies
Open accessAbstract
A collaboration of multidisciplinary experts on the delivery of pharmaceutical aerosols was facilitated by the European Respiratory Society (ERS) and the International Society for Aerosols in Medicine (ISAM), in order to draw up a consensus statement with clear, up-to-date recommendations that enable the pulmonary physician to choose the type of aerosol delivery device that is most suitable for their patient. The focus of the consensus statement is the patient-use aspect of the aerosol delivery devices that are currently available. The subject was divided into different topics, which were in turn assigned to at least two experts. The authors searched the literature according to their own strategies, with no central literature review being performed. To achieve consensus, draft reports and recommendations were reviewed and voted on by the entire panel. Specific recommendations for use of the devices can be found throughout the statement. Healthcare providers should ensure that their patients can and will use these devices correctly. This requires that the clinician: is aware of the devices that are currently available to deliver the prescribed drugs; knows the various techniques that are appropriate for each device; is able to evaluate the patient's inhalation technique to be sure they are using the devices properly; and ensures that the inhalation method is appropriate for each patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GLOBAL STRATEGY FOR ASTHMA MANAGEMENT AND PREVENTION
PAUWELS, R. A. (1996) · Arerugī/Arerugi · doi:10.15036/arerugi.45.792 · Cited by 9,994
The Nature of Small-Airway Obstruction in Chronic Obstructive Pulmonary Disease
Hogg, J. C., Chu, F., Utokaparch, S., Woods, R., Elliott, W. M., Buzatu, L., Cherniack, R. M., Rogers, R. M., Sciurba, F. C., Coxson, H. O., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032158 · Cited by 3,782
Can Guideline-defined Asthma Control Be Achieved?: The Gaining Optimal Asthma ControL Study
Bateman, E. D., Boushey, H. A., Bousquet, J., Busse, W. W., Clark, T. J. H., Pauwels, R. A., & Pedersen, S. E. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200401-033oc · Cited by 1,594
Labiris, N. R., & Dolovich, M. B. (2003) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2003.01892.x · Cited by 1,245
Cystic Fibrosis Pulmonary Guidelines: Chronic Medications for Maintenance of Lung Health
Flume, P. A., O'Sullivan, B. P., Robinson, K. A., Goss, C. H., Mogayzel, P. J., Willey-Courand, D. B., Bujan, J., Finder, J., Lester, M., Quittell, L., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200705-664oc · Cited by 1,024
Device Selection and Outcomes of Aerosol Therapy: Evidence-Based Guidelines
Dolovich, M. B., Ahrens, R. C., Hess, D. R., Anderson, P., Dhand, R., Rau, J. L., Smaldone, G. C., & Guyatt, G. (2005) · Chest · doi:10.1378/chest.127.1.335 · Cited by 794
Self-citationGardon, J., Gardon-Wendel, N., Demanga-Ngangue, Kamgno, J., Chippaux, J.-P., & Boussinesq, M. (1997) · The Lancet · doi:10.1016/s0140-6736(96)11094-1 · Cited by 745
Mucus Clearance and Lung Function in Cystic Fibrosis with Hypertonic Saline
Donaldson, S. H., Bennett, W. D., Zeman, K. L., Knowles, M. R., Tarran, R., & Boucher, R. C. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa043891 · Cited by 694
Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD
Lavorini, F., Magnan, A., Christophe Dubus, J., Voshaar, T., Corbetta, L., Broeders, M., Dekhuijzen, R., Sanchis, J., Viejo, J. L., Barnes, P., et al. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2007.11.003 · Cited by 609
Self-citationRegional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Respiratory Drug Delivery (1989)
Byron, P. R. (2018) · CRC Press eBooks · doi:10.4324/9780203710456 · Cited by 449
Leach, C., Davidson, P., & Boudreau, R. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12061346 · Cited by 430
Guidelines on the management of asthma.
Jones, K. P. (1993) · Thorax · doi:10.1136/thx.48.10.1050 · Cited by 422
Brocklebank, D., Ram, F., Wright, J., Barry, P., Cates, C., Davies, L., Douglas, G., Muers, M., Smith, D., & White, J. (2001) · Health Technology Assessment · doi:10.3310/hta5260 · Cited by 401
Molimard, M., Raherison, C., Lignot, S., Depont, F., Abouelfath, A., & Moore, N. (2003) · Journal of Aerosol Medicine · doi:10.1089/089426803769017613 · Cited by 398
Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Welsh, E. J., & Rowe, B. H. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052.pub3 · Cited by 359
Nebulised hypertonic saline solution for acute bronchiolitis in infants
Zhang, L., Mendoza-Sassi, R. A., Wainwright, C., & Klassen, T. P. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006458.pub3 · Cited by 353
CLARK, A. R., & HOLLINGWORTH, A. M. (1993) · Journal of Aerosol Medicine · doi:10.1089/jam.1993.6.99 · Cited by 332
Walmrath, D., Schneider, T., Schermuly, R., Olschewski, H., Grimminger, F., & Seeger, W. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.3.8630585 · Cited by 331
Newman, S. P., Weisz, A. W., Talaee, N., & Clarke, S. W. (1991) · Thorax · doi:10.1136/thx.46.10.712 · Cited by 326
Corticosteroids: The drugs to beat
Barnes, P. J. (2006) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2005.12.052 · Cited by 301
Crompton, G. K., Barnes, P. J., Broeders, M., Corrigan, C., Corbetta, L., Dekhuijzen, R., Dubus, J. C., Magnan, A., Massone, F., Sanchis, J., et al. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.01.008 · Cited by 280
Self-citationCo-Chairmen of the Task Force:, Boe, J., Dennis, J. H., O'Driscoll, B. R., Members of Task Force:, Bauer, T. T., Carone, M., Dautzenberg, B., Diot, P., Heslop, K., et al. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00220001 · Cited by 280
Self-citationAutoradiographic visualization of beta-adrenoceptor subtypes in human lung.
Carstairs, J. R., Nimmo, A. J., & Barnes, P. J. (1985) · PubMed · doi:10.1164/arrd.1985.132.3.541 · Cited by 278
Influence of inspiratory flow rate upon the effect of a Turbuhaler.
Pedersen, S. S., Hansen, O. R., & Fuglsang, G. (1990) · Archives of Disease in Childhood · doi:10.1136/adc.65.3.308 · Cited by 270
Heijerman, H., Westerman, E., Conway, S., & Touw, D. (2009) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2009.04.005 · Cited by 264
Busse, W. W., Brazinsky, S., Jacobson, K., Stricker, W., Schmitt, K., Vanden Burgt, J., Donnell, D., Hannon, S., & Colice, G. L. (1999) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(99)70016-3 · Cited by 260
Autoradiographic Visualization of Muscarinic Receptor Subtypes in Human and Guinea Pig Lung
Mak, J. C. W., & Barnes, P. J. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.6.1559 · Cited by 255
Quantitative Deposition of Aerosolized Gentamicin in Cystic Fibrosis
Ilowite, J. S., Gorvoy, J. D., & Smaldone, G. C. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.6.1445 · Cited by 247
Leach, C. L., Davidson, P. J., Hasselquist, B. E., & Boudreau, R. J. (2002) · Chest · doi:10.1378/chest.122.2.510 · Cited by 231
Aerosol Delivery and Modern Mechanical Ventilation
Miller, D. D., Amin, M. M., Palmer, L. B., Shah, A. R., & Smaldone, G. C. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1167oc · Cited by 224
Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers
Pauwels, R., Newman, S., & Borgstrom, L. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10092127 · Cited by 198
Choosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.04.012 · Cited by 190
Self-citationBritish guidelines on the management of asthma.
Clancy, K. X. (2004) · PubMed · Cited by 189
The Expanding Role of Aerosols in Systemic Drug Delivery, Gene Therapy, and Vaccination
Laube, B. L. (2005) · Respiratory Care · doi:10.4187/respcare.05501161 · Cited by 176
Self-citationEffects of various inhalation modes on the deposition of radioactive pressurized aerosols.
Newman, S. P., Pavia, D., GARLAND, N., & Clarke, S. W. (1982) · PubMed · Cited by 172
BISGAARD, H., GILLIES, J., GROENEWALD, M., & MADEN, C. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9811024 · Cited by 171
Glucocorticoid receptor localization in normal and asthmatic lung.
Adcock, I. M., Gilbey, T., Gelder, C. M., Chung, K. F., & Barnes, P. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810618 · Cited by 171
ROBINSON, T. D., FREIBERG, D. B., REGNIS, J. A., & YOUNG, I. H. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9904119 · Cited by 169
An audiovisual reminder function improves adherence with inhaled corticosteroid therapy in asthma
Charles, T., Quinn, D., Weatherall, M., Aldington, S., Beasley, R., & Holt, S. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2006.11.700 · Cited by 168
Holding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Crilly, J. A., & Rowe, B. H. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052.pub2 · Cited by 160
Williamson, I., Matusiewicz, S. P., Brown, P., Greening, A. P., & Crompton, G. K. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08040590 · Cited by 158
Inhaled corticosteroids for asthma: impact of practice level device switching on asthma control
Thomas, M. D., Price, D. B., Chrystyn, H., Lloyd, A., Williams, A., & von Ziegenweidt, J. (2009) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-9-1 · Cited by 147
Self-citationBeclomethasone/formoterolversusbudesonide/formoterol combination therapy in asthma
Papi, A. A., Paggiaro, P., Nicolini, G., Vignola, A. M., & Fabbri, L. M. (2006) · European Respiratory Journal · doi:10.1183/09031936.00095906 · Cited by 139
Inhaled therapy in elderly COPD patients; time for re-evaluation?
Jarvis, S., Ind, P. W., & Shiner, R. J. (2007) · Age and Ageing · doi:10.1093/ageing/afl174 · Cited by 134
Feller-Kopman, D. J., Schwartzstein, R. M., Robinson, T., & Young, I. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.16372a · Cited by 133
Beclomethasone/formoterol vs fluticasone/salmeterol inhaled combination in moderate to severe asthma
Papi, A. A., Paggiaro, P. L., Nicolini, G., Vignola, A. M., Fabbri, L. M., & ICAT SE study group (2007) · Allergy · doi:10.1111/j.1398-9995.2007.01493.x · Cited by 133
Leach, C., Davidson, P. J., Hasselquist, B. E., & Boudreau, R. J. (2005) · Journal of Aerosol Medicine · doi:10.1089/jam.2005.18.379 · Cited by 105
New Aerosol Delivery Devices for Cystic Fibrosis
Kesser, K. C., & Geller, D. E. (2009) · Respiratory Care · doi:10.4187/002013209790983250 · Cited by 103
Comparison of twenty three nebulizer/compressor combinations for domiciliary use
Smith, E. C., Denyer, J., & Kendrick, A. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08071214 · Cited by 99
Variation in Pediatric Aerosol Delivery: Importance of Facemask
Smaldone, G. C., Berg, E., & Nikander, K. (2005) · Journal of Aerosol Medicine · doi:10.1089/jam.2005.18.354 · Cited by 91
Waldrep, J. C., Keyhani, K., Black, M., & Knight, V. (1994) · CHEST Journal · doi:10.1378/chest.105.1.106 · Cited by 88
Kleemann, E., Schmehl, T., Gessler, T., Bakowsky, U., Kissel, T., & Seeger, W. (2006) · Pharmaceutical Research · doi:10.1007/pl00022055 · Cited by 87
Schulte, M. M., Osseiran, K., Betz, R., Wencker, M., Brand, P., Meyer, T. S., & Haidl, P. (2008) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2007.0634 · Cited by 85
Putensen, C., Hörmann, C., Kleinsasser, A. T., & Putensen-Himmer, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9609017 · Cited by 77
Adaptive Aerosol Delivery (AAD®) technology
Denyer, J., Nikander, K., & Smith, N. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.165 · Cited by 75
Peripheral deposition of α1‐protease inhibitor using commercial inhalation devices
Brand, P., Beckmann, H., Enriquez, M. M., Meyer, T. S., Müllinger, B., Sommerer, K., Weber, N., Weuthen, T., & Scheuch, G. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00096802 · Cited by 70
True device compliance: the need to consider both competence and contrivance
Brennan, V. K., Osman, L. M., Graham, H., Critchlow, A., & Everard, M. L. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2004.05.015 · Cited by 62
Self-citationSelecting and using nebuliser equipment
Kendrick, A. H., Smith, E. C., & Wilson, R. S. (1997) · Thorax · doi:10.1136/thx.52.2008.s92 · Cited by 60
The Mask for Noninvasive Ventilation: Principles of Design and Effects on Aerosol Delivery
HESS, D. R. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0574 · Cited by 58
Inhaler choice in primary practice
Chapman, K. R., Voshaar, T., & Virchow, J. C. (2005) · European Respiratory Review · doi:10.1183/09059180.05.00009607 · Cited by 58
Self-citationMedicines used in respiratory diseases only seen in children
Lenney, W., Boner, A. L., Bont, L., Bush, A., Carlsen, K.-H., Eber, E., Fauroux, B., Götz, M., Greenough, A., Grigg, J., et al. (2009) · European Respiratory Journal · doi:10.1183/09031936.00166508 · Cited by 40
Steed, K. P., Towse, L., Freund, B., & Newman, S. P. (1997) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(96)00016-4 · Cited by 38
In Vivo Measurements of Aerosol Dose and Distribution: Clinical Relevance
Laube, B. L. (1996) · Journal of Aerosol Medicine · doi:10.1089/jam.1996.9.suppl_1.s-77 · Cited by 36
Self-citationMoore, A. C., & Stone, S. (2004) · International Journal of Clinical Practice · doi:10.1111/j.1368-5031.2004.00123.x · Cited by 36
Bousquet, J., Poli, G., Acerbi, D., Monno, R., Ramael, S., & Nollevaux, F. (2009) · Clinical Pharmacokinetics · doi:10.2165/00003088-200948060-00001 · Cited by 26
What you need to know about inhalers and how to use them
Chrystyn, H., & Price, D. B. (2009) · Prescriber · doi:10.1002/psb.529 · Cited by 20
Self-citation
Cited by
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Systematic Review of Errors in Inhaler Use
Sanchis, J., Gich, I., & Pedersen, S. (2016) · CHEST · doi:10.1016/j.chest.2016.03.041 · Cited by 538
Medication adherence and the risk of severe asthma exacerbations: a systematic review
Engelkes, M., Janssens, H. M., de Jongste, J. C., Sturkenboom, M. C. J. M., & Verhamme, K. M. C. (2015) · European Respiratory Journal · doi:10.1183/09031936.00075614 · Cited by 534
Self-citationAdherence to inhaled therapies, health outcomes and costs in patients with asthma and COPD
Mäkelä, M. J., Backer, V., Hedegaard, M., & Larsson, K. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.04.005 · Cited by 485
International consensus on (ICON) pediatric asthma
Papadopoulos, N. G., Arakawa, H., Carlsen, K. ‐., Custovic, A., Gern, J., Lemanske, R., Le Souef, P., Mäkelä, M., Roberts, G., Wong, G., et al. (2012) · Allergy · doi:10.1111/j.1398-9995.2012.02865.x · Cited by 455
Self-citation
Metadata
- Authors
- Laube, B. L., Janssens, H. M., de Jongh, F. H. C., Devadason, S. G., Dhand, R., Diot, P., Everard, M. L., Horvath, I., Navalesi, P., Voshaar, T., & Chrystyn, H.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-02-10
- Volume
- 37
- Issue
- 6
- Pages
- 1308-1417
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2101909755
- Cited by
- 806
- References
- 67
- FWCI
- 32.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.