Cough aerosol in healthy participants: fundamental knowledge to optimize droplet-spread infectious respiratory disease management
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The Influenza A H1N1 virus can be transmitted via direct, indirect, and airborne route to non-infected subjects when an infected patient coughs, which expels a number of different sized droplets to the surrounding environment as an aerosol. The objective of the current study was to characterize the human cough aerosol pattern with the aim of developing a standard human cough bioaerosol model for Influenza Pandemic control. METHOD: 45 healthy non-smokers participated in the open bench study by giving their best effort cough. A laser diffraction system was used to obtain accurate, time-dependent, quantitative measurements of the size and number of droplets expelled by the cough aerosol. RESULTS: Voluntary coughs generated droplets ranging from 0.1 - 900 microns in size. Droplets of less than one-micron size represent 97% of the total number of measured droplets contained in the cough aerosol. Age, sex, weight, height and corporal mass have no statistically significant effect on the aerosol composition in terms of size and number of droplets. CONCLUSIONS: We have developed a standard human cough aerosol model. We have quantitatively characterized the pattern, size, and number of droplets present in the most important mode of person-to-person transmission of IRD: the cough bioaerosol. Small size droplets (< 1 μm) predominated the total number of droplets expelled when coughing. The cough aerosol is the single source of direct, indirect and/or airborne transmission of respiratory infections like the Influenza A H1N1 virus. STUDY DESIGN: Open bench, Observational, Cough, Aerosol study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultChao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultGuideline for Isolation Precautions in Hospitals
Garner, J. S., & Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1086/647190 · Cited by 1,068
Guideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 1×
“The fact that several of the most prestigious international professional organizations dealing with lung health and/or respiratory diseases, including the Council of Canadian Academies, are not discussing droplet formation and expulsion during coughing as a critical factor in IRD transmission and dispersion indicates…”
BackgroundTransmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744
ERS guidelines on the assessment of cough
Morice, A. H., Fontana, G. A., Belvisi, M. G., Birring, S. S., Chung, K. F., Dicpinigaitis, P. V., Kastelik, J. A., McGarvey, L. P., Smith, J. A., Tatar, M., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00101006 · Cited by 693
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 1×
“Other than the general suggestion to “cover your mouth when coughing“ or to voluntarily quarantine yourself (i.e. “if you have flu symptoms, please delay your visit“), we found no evidence-based information on procedures or techniques regarding cough aerosol control at the source, the respiratory…”
BackgroundModality of human expired aerosol size distributions
Johnson, G. R., Morawska, L., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., Katoshevski, D., et al. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.07.009 · Cited by 655 · cited 1×
“Johnson in a recent publication, using a different methodology and technique, also reported a third mode peaking at around 200 μm [49].”
MethodManaging Cough as a Defense Mechanism and as a Symptom
Irwin, R. S., Boulet, L.-P., Cloutier, M. M., Fuller, R., Gold, P. M., Hoffstein, V., Ing, A. J., McCool, F. D., O’Byrne, P., Poe, R. H., et al. (1998) · Chest · doi:10.1378/chest.114.2_supplement.133s · Cited by 648
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605 · cited 1×
“When the layer of mucus lining the airways interacts with the high-speed airflow of the expulsive phase (up to100 km/h) [25,26] droplets of different sizes are formed and forced up the airway tree, during which droplet collision and coalescing may occur.”
BackgroundGuideline for Isolation Precautions in Hospitals
Garner, J. S. (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30142367 · Cited by 590
Aerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589 · cited 1×
“The fact that several of the most prestigious international professional organizations dealing with lung health and/or respiratory diseases, including the Council of Canadian Academies, are not discussing droplet formation and expulsion during coughing as a critical factor in IRD transmission and dispersion indicates…”
BackgroundTransmission of Influenza: Implications for Control in Health Care Settings
Weinstein, R. A., Bridges, C. B., Kuehnert, M. J., & Hall, C. B. (2003) · Clinical Infectious Diseases · doi:10.1086/378292 · Cited by 536
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultThe Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultMurray and Nadel’s Textbook of Respiratory Medicine
Nomellini, V., & Chen, H. (2012) · Journal of Surgical Research · doi:10.1016/j.jss.2011.08.019 · Cited by 430
Influenza in the acute hospital setting
Salgado, C. D., Farr, B. M., Hall, K. K., & Hayden, F. G. (2002) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(02)00221-9 · Cited by 417 · cited 1×
“Consequently, viruses such as Influenza A H1N1 are transmitted when an infected patient expels droplets of different sizes loaded with pathogenic microorganisms, to the surrounding environment as an aerosol during coughing [17-22].”
BackgroundInhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultThe guinea pig as a transmission model for human influenza viruses
Lowen, A. C., Mubareka, S., Tumpey, T. M., García-Sastre, A., & Palese, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604157103 · Cited by 354 · cited 1×
“Interestingly, a group of researchers led by Palesi [46,47], have published several studies indicating that, using a small mammalian model, a viral infection was transmitted to animals in different cages connected only by a tube with no direct contact involved.”
BackgroundTang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0295.focus · Cited by 300 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultGuideline for isolation precautions in hospitals
GARNER, J., & SIMMONS, B. (1984) · American Journal of Infection Control · doi:10.1016/0196-6553(84)90025-7 · Cited by 287
Sullivan, S. J., Jacobson, R. M., Dowdle, W. R., & Poland, G. A. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2009.0588 · Cited by 225
Clearance of mucus by simulated cough
King, M., Brock, G., & Lundell, C. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.6.1776 · Cited by 221 · cited 1×
“05) with respect to the non-smoker population [50-53].”
BackgroundSelf-citationTransmission of Influenza Virus via Aerosols and Fomites in the Guinea Pig Model
Mubareka, S., Lowen, A. C., Steel, J., Coates, A. L., García‐Sastre, A., & Palese, P. (2009) · The Journal of Infectious Diseases · doi:10.1086/597073 · Cited by 210 · cited 1×
“Interestingly, a group of researchers led by Palesi [46,47], have published several studies indicating that, using a small mammalian model, a viral infection was transmitted to animals in different cages connected only by a tube with no direct contact involved.”
BackgroundTransmission of viral respiratory infections in the home
GOLDMANN, D. A. (2000) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-200010001-00002 · Cited by 196 · cited 1×
“Consequently, viruses such as Influenza A H1N1 are transmitted when an infected patient expels droplets of different sizes loaded with pathogenic microorganisms, to the surrounding environment as an aerosol during coughing [17-22].”
BackgroundParticle Concentration in Exhaled Breath
FAIRCHILD, C. I., & STAMPFER, J. F. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385868 · Cited by 175 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultSchwarz, K., Biller, H., Windt, H., Koch, W., & Hohlfeld, J. M. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0809 · Cited by 119 · cited 3×
“During our brief literature review, we found several key differences between those studies and our methods: they all used closed systems of various designs to assess the respiratory droplets; the majority of them used equipment with much lower resolution, limited range of sizes and biased droplet collection to charact…”
MethodResultUse of Quarantine to Prevent Transmission of Severe Acute Respiratory Syndrome—Taiwan, 2003
(2003) · JAMA · doi:10.1001/jama.290.8.1021 · Cited by 112
The numbers and the sites of origin of the droplets expelled during expiratory activities.
Jp, D. (1945) · PubMed Central · Cited by 106
The role of mucus viscoelasticity in cough clearance
King, M. (1987) · Biorheology · doi:10.3233/bir-1987-24611 · Cited by 99
Self-citationNosocomial transmission of influenza
Stott, D. J., Kerr, G., & Carman, W. F. (2002) · Occupational Medicine · doi:10.1093/occmed/52.5.249 · Cited by 95 · cited 1×
“Consequently, viruses such as Influenza A H1N1 are transmitted when an infected patient expels droplets of different sizes loaded with pathogenic microorganisms, to the surrounding environment as an aerosol during coughing [17-22].”
BackgroundRoyston, P. J. (1993) · Statistics in Medicine · doi:10.1002/sim.4780120209 · Cited by 78
Impact of Health on Particle Size of Exhaled Respiratory Aerosols: Case‐control Study
Hersen, G., Moularat, S., Robine, E., Géhin, E., Corbet, S., Vabret, A., & Freymuth, F. (2008) · CLEAN – Soil, Air, Water · doi:10.1002/clen.200700189 · Cited by 56
Next Flu Pandemic: What to Do Until the Vaccine Arrives?
Morse, S. S., Garwin, R. L., & Olsiewski, P. J. (2006) · Science · doi:10.1126/science.1135823 · Cited by 42
Zayas, J. G., Dimitry, J., Zayas, A. I., O’Brien, D. W., & King, M. (2005) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-5-11 · Cited by 37 · cited 2×
“This is a concept we described in previous publications [44,45].”
BackgroundResultSelf-citationSpectroscopic methods for medical diagnosis at terahertz wavelengths
Reid, C. B. (2009) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 37
Bronchial Mucus Properties in Lung Cancer: Relationship with Site of Lesion
Zayas, J. G., Rubin, B. K., York, E. L., Lien, D. C., & King, M. (1999) · Canadian Respiratory Journal · doi:10.1155/1999/459084 · Cited by 14 · cited 1×
“Previous studies found that viscoelastic properties of tracheal mucus from subjects exposed to tobacco smoke determined by rheological analysis are different (p < 0.05) with respect to the non-smoker population [50] [51] [52] [53] .”
BackgroundInfluentialSelf-citation
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Aerosol Emission and Superemission during Human Speech Increase with Voice Loudness
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-38808-z · Cited by 919
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828
The fluid dynamics of disease transmission
Bourouiba, L. (2021) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-060220-113712 · Cited by 366
“…crown splashes upon drop impact on a thin film (Roisman & Tropea 2002, Josserand & Zaleski 2003, Berberović et al. 2009) or a deep pool (Zhang et al. 2012, Agbaglah et al. 2015), crescent-moon splashes (Roisman et al. 2002, Gilet & Bourouiba 2015,Wang & Bourouiba 2018a) (Figures 11a,b…”
BackgroundSimulated Sunlight Rapidly Inactivates SARS-CoV-2 on Surfaces
Ratnesar-Shumate, S., Williams, G., Green, B., Krause, M., Holland, B., Wood, S., Bohannon, J., Boydston, J., Freeburger, D., Hooper, I., et al. (2020) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa274 · Cited by 356
Metadata
- Authors
- Zayas, G., Chiang, M. C., Wong, E., MacDonald, F., Lange, C. F., Senthilselvan, A., & King, M.
- Venue
- BMC Pulmonary Medicine
- Published
- 2012-03-21
- Volume
- 12
- Issue
- 1
- Pages
- 11-11
- ISSN
- 1471-2466 (ISSN-L)
- OpenAlex
- W2064935442
- Cited by
- 227
- References
- 38
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.