Validity of actigraphs uniaxial and triaxial accelerometers for assessment of physical activity in adults in laboratory conditions
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Few studies to date have directly compared the Actigraphs GT1M and the GT3X, it would be of tremendous value to know if these accelerometers give similar information about intensities of PA. Knowing if output is similar would have implications for cross-examination of studies. The purpose of the study was to assess the validity of the GT1M and the GT3X Actigraph accelerometers for the assessment of physical activity against oxygen consumption in laboratory conditions. METHODS: Forty-two college-aged participants aged 18-25 years wore the GT1M and the GT3X on their right hip during treadmill exercise at three different speeds, slow walking 4.8 km.h-1, fast walking 6.4 km.h-1, and running 9.7 km.h-1). Oxygen consumption was measured minute-by minute using a metabolic system. Bland-Altman plots were used to assess agreement between activity counts from the GT3X and GT1M, and correlations were assessed the ability of the accelerometers to assess physical activity. RESULTS: Bias for 4.8 km.h-1 was 2814.4 cpm (limits 1211.3 to 4417.4), for 6.4 km.h-1 was 3713.6 cpm (limits 1573.2 to 5854.0), and for 9.7 km.h-1 was-3811.2 cpm (limits 842.1 to 6780.3). Correlations between counts per minute for the GT1M and the GT3X were significantly correlated with VO2 (r = 0.881, p < 0.001; r = 0.810, p < 0.001 respectively). CONCLUSION: The present study showed that both the GT1M and the GT3X accurately measure physical activity when compared to oxygen consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Establishing a standard definition for child overweight and obesity worldwide: international survey
Cole, T. J. (2000) · BMJ · doi:10.1136/bmj.320.7244.1240 · Cited by 16,480
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“While increasing number of adult and pediatric studies use Actigraphs uniaxial accelerometers [7-15], and various versions have been introduced over the years, numerous investigators have reported on the validity to assess physical activity in the laboratory and in field settings [16-19], to estimate energy expenditur…”
BackgroundMethodValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317 · cited 6×
“The GT3X measures acceleration in three individual orthogonal planes (VT, AP, and medio-lateral (ML)) and provides activity counts as a composite vector magnitude of these three axes (VM3) [4-6,14].”
BackgroundResultInfluentialThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
Cited by
Cleland, C., Ferguson, S., Ellis, G., & Hunter, R. F. (2018) · BMC Medical Research Methodology · doi:10.1186/s12874-018-0642-3 · Cited by 407
Füzéki, E., Engeroff, T., & Banzer, W. (2017) · Sports Medicine · doi:10.1007/s40279-017-0724-0 · Cited by 363
McDermott, M. M., Spring, B., Berger, J. S., Treat-Jacobson, D., Conte, M. S., Creager, M. A., Criqui, M. H., Ferrucci, L., Gornik, H. L., Guralnik, J. M., et al. (2018) · JAMA · doi:10.1001/jama.2018.3275 · Cited by 211
Lynch, B. M., Nguyen, N. H., Moore, M. M., Reeves, M. M., Rosenberg, D. E., Boyle, T., Vallance, J. K., Milton, S., Friedenreich, C. M., & English, D. R. (2019) · Cancer · doi:10.1002/cncr.32143 · Cited by 171
“The Sasaki cut point was employed as the primary measure of MVPA because this method uses the acceleration recorded across 3 axes.(29)”
MethodLee, W., Lin, K.-Y., Seto, E., & Migliaccio, G. C. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.06.012 · Cited by 163
Lotzke, H., Brisby, H., Gutke, A., Hägg, O., Jakobsson, M., Smeets, R., & Lundberg, M. (2019) · Physical Therapy · doi:10.1093/ptj/pzz020 · Cited by 112
“44 The variables, steps per day, time in moderate-to-vigorous physical activity, time spent in light physical activity, and time spent sedentary, were analyzed.”
Oesen, S., Halper, B., Hofmann, M., Jandrasits, W., Franzke, B., Strasser, E.-M., Graf, A., Tschan, H., Bachl, N., Quittan, M., et al. (2015) · Experimental Gerontology · doi:10.1016/j.exger.2015.08.013 · Cited by 100
Zisko, N., Carlsen, T., Salvesen, Ø., Aspvik, N. P., Ingebrigtsen, J. E., Wisløff, U., & Stensvold, D. (2015) · BMC Geriatrics · doi:10.1186/s12877-015-0093-1 · Cited by 32
“VA ð Þ(2) þ antero−posterior ð Þ(2) þ medio−lateral ð Þ(2) q [20].”
Hartman, S. J., Marinac, C. R., Bellettiere, J., Godbole, S., Natarajan, L., Patterson, R. E., & Kerr, J. (2017) · Supportive Care in Cancer · doi:10.1007/s00520-017-3657-0 · Cited by 32
“The ActiGraph is widely used in the field of physical activity and sedentary behavior research and has good validation with VO2 max [29].”
MethodAge-Related Adverse Inflammatory and Metabolic Changes Begin Early in Adulthood
Parker, D., Sloane, R., Pieper, C. F., Hall, K. S., Kraus, V. B., Kraus, W. E., Huebner, J. L., Ilkayeva, O. R., Bain, J. R., Newby, L. K., et al. (2019) · The Journals of Gerontology: Series A · doi:10.1093/gerona/gly121 · Cited by 31
Naugle, K. E., Carey, C., Ohlman, T., Godza, M., Mikesky, A., & Naugle, K. M. (2019) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002997 · Cited by 15
Van Roessel, I. M. A. A., Van Schaik, J., Kleinlugtenbelt, L. B., van Duijn, S. N., Burghard, M., Takken, T., Tissing, W. J. E., Bekkering, W. P., & van Santen, H. M. (2025) · Supportive Care in Cancer · doi:10.1007/s00520-025-09361-5 · Cited by 3
Metadata
- Authors
- Kelly, L. A., McMillan, D. G., Anderson, A., Fippinger, M., Fillerup, G., & Rider, J.
- Venue
- BMC Medical Physics
- Published
- 2013-11-26
- Volume
- 13
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1756-6649 (ISSN-L)
- OpenAlex
- W2022669027
- Cited by
- 220
- References
- 43
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.