Validity of actigraphs uniaxial and triaxial accelerometers for assessment of physical activity in adults in laboratory conditions
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Few studies to date have directly compared the Actigraphs GT1M and the GT3X, it would be of tremendous value to know if these accelerometers give similar information about intensities of PA. Knowing if output is similar would have implications for cross-examination of studies. The purpose of the study was to assess the validity of the GT1M and the GT3X Actigraph accelerometers for the assessment of physical activity against oxygen consumption in laboratory conditions. METHODS: Forty-two college-aged participants aged 18-25 years wore the GT1M and the GT3X on their right hip during treadmill exercise at three different speeds, slow walking 4.8 km.h-1, fast walking 6.4 km.h-1, and running 9.7 km.h-1). Oxygen consumption was measured minute-by minute using a metabolic system. Bland-Altman plots were used to assess agreement between activity counts from the GT3X and GT1M, and correlations were assessed the ability of the accelerometers to assess physical activity. RESULTS: Bias for 4.8 km.h-1 was 2814.4 cpm (limits 1211.3 to 4417.4), for 6.4 km.h-1 was 3713.6 cpm (limits 1573.2 to 5854.0), and for 9.7 km.h-1 was-3811.2 cpm (limits 842.1 to 6780.3). Correlations between counts per minute for the GT1M and the GT3X were significantly correlated with VO2 (r = 0.881, p < 0.001; r = 0.810, p < 0.001 respectively). CONCLUSION: The present study showed that both the GT1M and the GT3X accurately measure physical activity when compared to oxygen consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Establishing a standard definition for child overweight and obesity worldwide: international survey
Cole, T. J. (2000) · BMJ · doi:10.1136/bmj.320.7244.1240 · Cited by 16,480
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“While increasing number of adult and pediatric studies use Actigraphs uniaxial accelerometers [7-15], and various versions have been introduced over the years, numerous investigators have reported on the validity to assess physical activity in the laboratory and in field settings [16-19], to estimate energy expenditur…”
BackgroundMethodValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317 · cited 6×
“The GT3X measures acceleration in three individual orthogonal planes (VT, AP, and medio-lateral (ML)) and provides activity counts as a composite vector magnitude of these three axes (VM3) [4-6,14].”
BackgroundResultInfluentialThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
Total energy expenditure and physical activity in young Scottish children: mixed longitudinal study
Reilly, J., Jackson, D., Montgomery, C., Kelly, L., Slater, C., Grant, S., & Paton, J. (2004) · The Lancet · doi:10.1016/s0140-6736(03)15331-7 · Cited by 430
Self-citationValidity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416
The Epidemiology of Walking for Physical Activity in the United States
EYLER, A. A., BROWNSON, R. C., BACAK, S. J., & HOUSEMANN, R. A. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000084622.39122.0c · Cited by 391
Comparison of pedometer and accelerometer measures of free-living physical activity
TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 386
Physical activity to prevent obesity in young children: cluster randomised controlled trial
Reilly, J. J., Kelly, L., Montgomery, C., Williamson, A., Fisher, A., McColl, J. H., Lo Conte, R., Paton, J. Y., & Grant, S. (2006) · BMJ · doi:10.1136/bmj.38979.623773.55 · Cited by 384
Self-citationEstimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Validation of the CSA accelerometer for assessing children??s physical activity
JANZ, K. F. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199403000-00015 · Cited by 327
Validity and Reliability issues in Objective Monitoring of Physical Activity
Bassett, D. R. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082783 · Cited by 326
Physical activity assessment with accelerometers
Westerterp, K. (1999) · International Journal of Obesity · doi:10.1038/sj.ijo.0800883 · Cited by 288
Comparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132379.09364.f8 · Cited by 238
Bouten, C. V., Verboeket-van de Venne, W. P., Westerterp, K. R., Verduin, M., & Janssen, J. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.1019 · Cited by 223
Objectively Measured Physical Activity in a Representative Sample of 3‐ to 4‐Year‐Old Children
Jackson, D. M., Reilly, J. J., Kelly, L. A., Montgomery, C., Grant, S., & Paton, J. Y. (2003) · Obesity Research · doi:10.1038/oby.2003.57 · Cited by 207 · cited 1×
“While increasing number of adult and pediatric studies use Actigraphs uniaxial accelerometers [7-15], and various versions have been introduced over the years, numerous investigators have reported on the validity to assess physical activity in the laboratory and in field settings [16-19], to estimate energy expenditur…”
BackgroundSelf-citationValidation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph
Hänggi, J. M., Phillips, L. R. S., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.012 · Cited by 196
Measuring Free‐Living Energy Expenditure and Physical Activity with Triaxial Accelerometry
Plasqui, G., Joosen, A. M. C. P., Kester, A. D., Goris, A. H. C., & Westerterp, K. R. (2005) · Obesity Research · doi:10.1038/oby.2005.165 · Cited by 183
Technical variability of the GT3X accelerometer
Santos-Lozano, A., Marín, P. J., Torres-Luque, G., Ruiz, J. R., Lucía, A., & Garatachea, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.005 · Cited by 180
Comparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Refined Two-Regression Model for the ActiGraph Accelerometer
CROUTER, S. E., KUFFEL, E., HAAS, J. D., FRONGILLO, E. A., & BASSETT, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c37458 · Cited by 176
Cain, K. L., Conway, T. L., Adams, M. A., Husak, L. E., & Sallis, J. F. (2013) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-10-51 · Cited by 161 · cited 3×
“One of the most widely used accelerometers in PA research is the Actigraph’s Uniaxial GT1M (Actigraph, Pensacola, FL) and more recently the company released the triaxial GT3X (Actigraph, Pensacola, FL) [3].”
BackgroundMethodInfluentialTracking Physical Activity and Sedentary Behavior in Young Children
Kelly, L. A., Reilly, J. J., Jackson, D. M., Montgomery, C., Grant, S., & Paton, J. Y. (2007) · Pediatric Exercise Science · doi:10.1123/pes.19.1.51 · Cited by 128 · cited 1×
“While increasing number of adult and pediatric studies use Actigraphs uniaxial accelerometers [7-15], and various versions have been introduced over the years, numerous investigators have reported on the validity to assess physical activity in the laboratory and in field settings [16-19], to estimate energy expenditur…”
BackgroundSelf-citationEffect of socioeconomic status on objectively measured physical activity
Kelly, L. A. (2005) · Archives of Disease in Childhood · doi:10.1136/adc.2005.080275 · Cited by 122 · cited 1×
“While increasing number of adult and pediatric studies use Actigraphs uniaxial accelerometers [7-15], and various versions have been introduced over the years, numerous investigators have reported on the validity to assess physical activity in the laboratory and in field settings [16-19], to estimate energy expenditur…”
BackgroundSelf-citationInfluence of Speed and Step Frequency during Walking and Running on Motion Sensor Output
ROWLANDS, A. V., STONE, M. R., & ESTON, R. G. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318031126c · Cited by 121
Accelerometer Prediction of Energy Expenditure: Vector Magnitude Versus Vertical Axis
HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181aa3a0e · Cited by 78
Technical Reliability Assessment of the Actigraph GT1M Accelerometer
Silva, P., Mota, J. A. P. S., Esliger, D., & Welk, G. J. (2010) · Measurement in Physical Education and Exercise Science · doi:10.1080/10913671003715524 · Cited by 77
Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children
COLEMAN, K. J., SAELENS, B. E., WIEDRICH-SMITH, M. D., FINN, J. D., & EPSTEIN, L. H. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199711000-00022 · Cited by 65
Validation of the ActiGraph Two-Regression Model for Predicting Energy Expenditure
ROTHNEY, M. P., BRYCHTA, R. J., MEADE, N. N., CHEN, K. Y., & BUCHOWSKI, M. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d5a984 · Cited by 65
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1841 · Cited by 53
Kelly, L. A., Reilly, J. J., Grant, S., & Paton, J. Y. (2005) · PubMed · Cited by 44
Self-citationEquivalence of accelerometer data for walking and running: Treadmill versus on land
Vanhelst, J., Zunquin, G., Theunynck, D., Mikulovic, J., Bui-Xuân, G., & Béghin, L. (2009) · Journal of Sports Sciences · doi:10.1080/02640410802680580 · Cited by 40
Fitzhugh, E. C., & Thompson, D. L. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.4.393 · Cited by 15 · cited 1×
“As a method for the assessment of physical activity (PA) they provide good evidence of validity and reliability [1,2].”
Method
Cited by
Cleland, C., Ferguson, S., Ellis, G., & Hunter, R. F. (2018) · BMC Medical Research Methodology · doi:10.1186/s12874-018-0642-3 · Cited by 407
Füzéki, E., Engeroff, T., & Banzer, W. (2017) · Sports Medicine · doi:10.1007/s40279-017-0724-0 · Cited by 363
McDermott, M. M., Spring, B., Berger, J. S., Treat-Jacobson, D., Conte, M. S., Creager, M. A., Criqui, M. H., Ferrucci, L., Gornik, H. L., Guralnik, J. M., et al. (2018) · JAMA · doi:10.1001/jama.2018.3275 · Cited by 211
Lynch, B. M., Nguyen, N. H., Moore, M. M., Reeves, M. M., Rosenberg, D. E., Boyle, T., Vallance, J. K., Milton, S., Friedenreich, C. M., & English, D. R. (2019) · Cancer · doi:10.1002/cncr.32143 · Cited by 171
“The Sasaki cut point was employed as the primary measure of MVPA because this method uses the acceleration recorded across 3 axes.(29)”
MethodLee, W., Lin, K.-Y., Seto, E., & Migliaccio, G. C. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.06.012 · Cited by 163
Metadata
- Authors
- Kelly, L. A., McMillan, D. G., Anderson, A., Fippinger, M., Fillerup, G., & Rider, J.
- Venue
- BMC Medical Physics
- Published
- 2013-11-26
- Volume
- 13
- Issue
- 1
- Pages
- 5-5
- ISSN
- 1756-6649 (ISSN-L)
- OpenAlex
- W2022669027
- Cited by
- 220
- References
- 43
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.