Reliability and validity of two fitness tracker devices in the laboratory and home environment for older community-dwelling people
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Two-thirds of older Australians are sedentary. Fitness trackers have been popular with younger people and may encourage older adults to become more active. Older adults may have different gait patterns and as such it is important to establish whether fitness trackers are valid and reliable for this population. The aim of the study was to test the reliability and validity of two fitness trackers (Fitbit Flex and ChargeHR) by step count when worn by older adults. Reliability and validity were tested in two conditions: 1) in the laboratory using a two-minute-walk-test (2MWT) and 2) in a free-living environment. METHODS: Two 2MWTs were completed while wearing the fitness trackers. Participants were videoed during each test. Participants were then given one fitness tracker and a GENEactiv accelerometer to wear at home for 14-days. RESULTS: Thirty-one participants completed two 2MWTs and 30 completed the free-living procedure. Intra Class Correlation's of the fitness trackers with direct observation of steps (criterion validity) was high (ICC:0.86,95%CI:0.76,0.93). However, both fitness trackers underestimated steps. Excellent test-retest reliability (ICC ≥ 0.75) was found between the two 2MWTs for each device, particularly the ChargeHR devices. Good strength of agreement was found for total distance and steps (fitness tracker) and moderate-to-vigorous physical activity (GENEactiv) for the free-living environment (Spearman Rho's 0.78 and 0.74 respectively). CONCLUSION: Reliability and validity of the Flex and ChargeHR when worn by older adults is good, however both devices underestimated step count within the laboratory environment. These fitness trackers appear suitable for consumer use and promoting physical activity for older adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349
Exercise as medicine - evidence for prescribing exercise as therapy in 26 different chronic diseases
Pedersen, B. K., & Saltin, B. (2015) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12581 · Cited by 3,514
Lack of Exercise Is a Major Cause of Chronic Diseases
Booth, F. W., Roberts, C. K., & Laye, M. J. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110025 · Cited by 2,575 · cited 1×
“org/publicdomain/ze some types of cancer and type 2 diabetes [2, 3].”
BackgroundTwo-, six-, and 12-minute walking tests in respiratory disease.
Butland, R. J., Pang, J., Gross, E. R., Woodcock, A. A., & Geddes, D. M. (1982) · BMJ · doi:10.1136/bmj.284.6329.1607 · Cited by 1,668
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“However, while there has been growth in testing the validity and reliability of fitness trackers with older people over the past few years [11] the evidence is still limited, particularly compared to other younger populations [11].”
BackgroundPractical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 18×
“As activity data deviates from normality, Spearman correlations were used to compare daily physical activity minutes, total distance travelled, step count and sleep for the fitness tracker (Fitbit) devices and accelerometer (GENEactiv) over the 14-days.”
BackgroundMethodInfluentialValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1×
“The distribution of error and testing for proportional bias is shown in the Bland-Altman plot analyses [26].”
MethodReliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182 · cited 3×
“The mean difference and 95% confidence intervals are illustrated using horizontal lines, which assist in identifying systematic trends or outliers [14, 24].”
BackgroundMethodInfluentialSushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152 · cited 2×
“Paired sample t-tests were used to examine the differences in mean step count for each device [19].”
MethodResultAccuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90
Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions
Brooke, S. M., An, H.-S., Kang, S.-K., Noble, J. M., Berg, K. E., & Lee, J.-M. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001571 · Cited by 79 · cited 1×
“Few studies have tested the validity and reliability of the ChargeHR to date [29, 30, 35, 36] and none have used older people as a sample population.”
BackgroundLeth, S., Hansen, J., Nielsen, O., & Dinesen, B. (2017) · Sensors · doi:10.3390/s17010211 · Cited by 64
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2020-8 · Cited by 29 · cited 1×
“count of the Flex with direct observation in younger adults found similar results to the present study, with the Flex underestimating the step count, with high ICC agreement found [18, 19, 27].”
Result
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[20,21,29,32,34,36,38,45,53,64-82] Wrist Discontinued 2015 Charge HR Fitbit”
BackgroundInfluentialTedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
“Finally, Burton et al [21] reported good reliability and validity for the Fitbit Flex and Fitbit Charge HR compared against a GENEactiv accelerometer in a free-living environment over 14 days.”
MethodTedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116
Barteit, S., Boudo, V., Ouedraogo, A., Zabré, P., Ouremi, L., Sié, A., Munga, S., Obor, D., Kwaro, D., Huhn, S., et al. (2021) · PLOS ONE · doi:10.1371/journal.pone.0257170 · Cited by 51
Metadata
- Authors
- Burton, E., Hill, K. D., Lautenschlager, N. T., Thøgersen-Ntoumani, C., Lewin, G., Boyle, E., & Howie, E.
- Venue
- BMC Geriatrics
- Published
- 2018-05-03
- Volume
- 18
- Issue
- 1
- Pages
- 103-103
- ISSN
- 1471-2318 (ISSN-L)
- OpenAlex
- W2801011643
- Cited by
- 70
- References
- 17
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.