CNNs for automatic glaucoma assessment using fundus images: an extensive validation
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Most current algorithms for automatic glaucoma assessment using fundus images rely on handcrafted features based on segmentation, which are affected by the performance of the chosen segmentation method and the extracted features. Among other characteristics, convolutional neural networks (CNNs) are known because of their ability to learn highly discriminative features from raw pixel intensities. METHODS: In this paper, we employed five different ImageNet-trained models (VGG16, VGG19, InceptionV3, ResNet50 and Xception) for automatic glaucoma assessment using fundus images. Results from an extensive validation using cross-validation and cross-testing strategies were compared with previous works in the literature. RESULTS: Using five public databases (1707 images), an average AUC of 0.9605 with a 95% confidence interval of 95.92-97.07%, an average specificity of 0.8580 and an average sensitivity of 0.9346 were obtained after using the Xception architecture, significantly improving the performance of other state-of-the-art works. Moreover, a new clinical database, ACRIMA, has been made publicly available, containing 705 labelled images. It is composed of 396 glaucomatous images and 309 normal images, which means, the largest public database for glaucoma diagnosis. The high specificity and sensitivity obtained from the proposed approach are supported by an extensive validation using not only the cross-validation strategy but also the cross-testing validation on, to the best of the authors' knowledge, all publicly available glaucoma-labelled databases. CONCLUSIONS: These results suggest that using ImageNet-trained models is a robust alternative for automatic glaucoma screening system. All images, CNN weights and software used to fine-tune and test the five CNNs are publicly available, which could be used as a testbed for further comparisons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Very Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148
Going deeper with convolutions
Szegedy, C., Liu, W., Jia, Y., Sermanet, P., Reed, S., Anguelov, D., Erhan, D., Vanhoucke, V., & Rabinovich, A. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298594 · Cited by 48,562
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380
(2014) · Cited by 33,419
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
The Elements of Statistical Learning
Hastie, T., Friedman, J., & Tibshirani, R. (2001) · Springer Series in Statistics · doi:10.1007/978-0-387-21606-5 · Cited by 24,162
Xception: Deep Learning with Depthwise Separable Convolutions
Chollet, F. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.195 · Cited by 20,380
On a Test of Whether one of Two Random Variables is Stochastically Larger than the Other
Mann, H. B., & Whitney, D. R. (1947) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177730491 · Cited by 14,320
CNN Features Off-the-Shelf: An Astounding Baseline for Recognition
Razavian, A. S., Azizpour, H., Sullivan, J., & Carlsson, S. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2014.131 · Cited by 4,451
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
Generalization and network design strategies
LeCun, Y. (1989) · Cited by 885
Mason, S. J., & Graham, N. E. (2002) · Quarterly Journal of the Royal Meteorological Society · doi:10.1256/003590002320603584 · Cited by 868
Robust Vessel Segmentation in Fundus Images
Budai, A., Bock, R., Maier, A., Hornegger, J., & Michelson, G. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/154860 · Cited by 642
Superpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
Cheng, J., Liu, J., Xu, Y., Yin, F., Wong, D. W. K., Tan, N.-M., Tao, D., Cheng, C.-Y., Aung, T., & Wong, T. Y. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2247770 · Cited by 593
Drishti-GS: Retinal image dataset for optic nerve head(ONH) segmentation
Sivaswamy, J., Krishnadas, S. R., Datt Joshi, G., Jain, M., & Syed Tabish, A. U. (2014) · 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867807 · Cited by 540
RIM-ONE: An open retinal image database for optic nerve evaluation
Fumero, F., Alayon, S., Sanchez, J. L., Sigut, J., & Gonzalez-Hernandez, M. (2011) · 2011 24th International Symposium on Computer-Based Medical Systems (CBMS) · doi:10.1109/cbms.2011.5999143 · Cited by 538
Optic Disk and Cup Segmentation From Monocular Color Retinal Images for Glaucoma Assessment
Joshi, G. D., Sivaswamy, J., & Krishnadas, S. R. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2106509 · Cited by 412
Glaucoma detection based on deep convolutional neural network
Chen, X., Xu, Y., Kee Wong, D. W., Wong, T. Y., & Liu, J. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318462 · Cited by 412
Standard Plane Localization in Fetal Ultrasound via Domain Transferred Deep Neural Networks
Chen, H., Ni, D., Qin, J., Li, S., Yang, X., Wang, T., & Heng, P. A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2425041 · Cited by 379
Glaucoma risk index:Automated glaucoma detection from color fundus images
Bock, R., Meier, J., Nyúl, L. G., Hornegger, J., & Michelson, G. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.006 · Cited by 361
Deep learning with non-medical training used for chest pathology identification
Bar, Y., Diamant, I., Wolf, L., & Greenspan, H. (2015) · SPIE Proceedings · doi:10.1117/12.2083124 · Cited by 290
Unregistered Multiview Mammogram Analysis with Pre-trained Deep Learning Models
Carneiro, G., Nascimento, J., & Bradley, A. P. (2015) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-24574-4_78 · Cited by 235
Automatic Detection of Optic Disc Based on PCA and Mathematical Morphology
Morales, S., Naranjo, V., Angulo, J., & Alcañiz, M. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2238244 · Cited by 221
Self-citationLevel-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI
Wong, D. W. K., Liu, J., Lim, J. H., Jia, X., Yin, F., Li, H., & Wong, T. Y. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649648 · Cited by 171
Convolutional neural network transfer for automated glaucoma identification
Orlando, J. I., Prokofyeva, E., del Fresno, M., & Blaschko, M. B. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2255740 · Cited by 164
Automatic Optic Disc Abnormality Detection in Fundus Images: A Deep Learning Approach
Alghamdi, H. S., Tang, H. L., Waheeb, S. A., & Pető, T. (2016) · Ophthalmic Medical Image Analysis International Workshop (OMIA) · doi:10.17077/omia.1042 · Cited by 71
Worldwide glaucoma through the looking glass
Bourne, R. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.083527 · Cited by 70
Automatic glaucoma diagnosis through medical imaging informatics
Liu, J., Zhang, Z., Wong, D. W. K., Xu, Y., Yin, F., Cheng, J. T., Tan, N. M., Kwoh, C. K., Xu, D., Tham, Y. C., et al. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001336 · Cited by 33
Cited by
Retinal Image Synthesis and Semi-Supervised Learning for Glaucoma Assessment
Diaz-Pinto, A., Colomer, A., Naranjo, V., Morales, S., Xu, Y., & Frangi, A. F. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903434 · Cited by 220
Self-citationDeep Learning for Optic Disc Segmentation and Glaucoma Diagnosis on Retinal Images
Sreng, S., Maneerat, N., Hamamoto, K., & Win, K. Y. (2020) · Applied Sciences · doi:10.3390/app10144916 · Cited by 184
“Nine datasets are readily available: REFUGE [5], ACRIMA [6], ORIGA [7], RIM-ONE [8], DRISHTI-GS1 [9], HRF [10], SiMES [11], SCES [12] and SiNDI [13].”
Method
Metadata
- Authors
- Diaz-Pinto, A., Morales, S., Naranjo, V., Köhler, T., Mossi, J. M., & Navea, A.
- Venue
- BioMedical Engineering OnLine
- Published
- 2019-03-20
- Volume
- 18
- Issue
- 1
- Pages
- 29-29
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2938600289
- Cited by
- 435
- References
- 30
- FWCI
- 25.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.