The exoskeleton expansion: improving walking and running economy
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Since the early 2000s, researchers have been trying to develop lower-limb exoskeletons that augment human mobility by reducing the metabolic cost of walking and running versus without a device. In 2013, researchers finally broke this ‘metabolic cost barrier’. We analyzed the literature through December 2019, and identified 23 studies that demonstrate exoskeleton designs that improved human walking and running economy beyond capable without a device. Here, we reviewed these studies and highlighted key innovations and techniques that enabled these devices to surpass the metabolic cost barrier and steadily improve user walking and running economy from 2013 to nearly 2020. These studies include, physiologically-informed targeting of lower-limb joints; use of off-board actuators to rapidly prototype exoskeleton controllers; mechatronic designs of both active and passive systems; and a renewed focus on human-exoskeleton interface design. Lastly, we highlight emerging trends that we anticipate will further augment wearable-device performance and pose the next grand challenges facing exoskeleton technology for augmenting human mobility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2018 IEEE International Conference on Robotics and Automation (ICRA)
(2018) · doi:10.1109/icra36916.2018 · Cited by 1,340
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Faster top running speeds are achieved with greater ground forces not more rapid leg movements
Weyand, P. G., Sternlight, D. B., Bellizzi, M. J., & Wright, S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.1991 · Cited by 994
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Self-citationNewman, A. B., Simonsick, E. M., Naydeck, B. L., Boudreau, R. M., Kritchevsky, S. B., Nevitt, M. C., Pahor, M., Satterfield, S., Brach, J. S., Studenski, S. A., et al. (2006) · JAMA · doi:10.1001/jama.295.17.2018 · Cited by 934
Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777
2015 IEEE International Conference on Robotics and Automation (ICRA)
(2015) · doi:10.1109/icra30979.2015 · Cited by 725
IEEE Transactions on Control Systems Technology
(2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.87 · Cited by 722
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Reducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Self-citationMechanics and energetics of level walking with powered ankle exoskeletons
Sawicki, G. S., & Ferris, D. P. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.009241 · Cited by 297
Self-citationA biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
It Pays to Have a Spring in Your Step
Sawicki, G. S., Lewis, C. L., & Ferris, D. P. (2009) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e31819c2df6 · Cited by 250
Self-citationEffect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
Self-citation2012 IEEE International Conference on Robotics and Automation
(2012) · doi:10.1109/icra15123.2012 · Cited by 244
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
The rise of the body bots [robotic exoskeletons
Guizzo, E., & Goldstein, H. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1515961 · Cited by 238
Altered Running Economy Directly Translates to Altered Distance-Running Performance
HOOGKAMER, W., KIPP, S., SPIERING, B. A., & KRAM, R. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001012 · Cited by 230
Mooney, L. M., & Herr, H. M. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0111-3 · Cited by 229
Variables related to increased mortality following out-patient pulmonary rehabilitation
Gerardi, D., Lovett, L., Benoit-Connors, M., Reardon, J., & ZuWallack, R. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09030431 · Cited by 225
Galle, S., Malcolm, P., Collins, S. H., & De Clercq, D. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0235-0 · Cited by 225
Jackson, R. W., & Collins, S. H. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01133.2014 · Cited by 205
Young, A. J., Kuiken, T. A., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056021 · Cited by 200
Self-citation2009 IEEE International Conference on Rehabilitation Robotics
(2009) · doi:10.1109/icorr15062.2009 · Cited by 191
Energetics of walking and running: insights from simulated reduced-gravity experiments
Farley, C. T., & McMahon, T. A. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.6.2709 · Cited by 189
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
Self-citationHuman-in-the-loop Bayesian optimization of wearable device parameters
Kim, M., Ding, Y., Malcolm, P., Speeckaert, J., Siviy, C., Walsh, C. J., & Kuindersma, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184054 · Cited by 178
Fully autonomous hip exoskeleton saves metabolic cost of walking
Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487663 · Cited by 177
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
An autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Koller, J. R., Jacobs, D. A., Ferris, D. P., & Remy, C. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0086-5 · Cited by 162
Yandell, M. B., Quinlivan, B., Popov, D., Walsh, C. J., & Zelik, K. E. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0247-9 · Cited by 161
Gregorczyk, K. N., Hasselquist, L., Schiffman, J. M., Bensel, C. K., Obusek, J. P., & Gutekunst, D. J. (2010) · Ergonomics · doi:10.1080/00140139.2010.512982 · Cited by 160
2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
(2015) · doi:10.1109/icorr34445.2015 · Cited by 159
2014 IEEE International Conference on Robotics and Automation (ICRA2014)
Kurita, Y. (2014) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.32.718 · Cited by 157
Reducing the Energy Cost of Human Running Using an Unpowered Exoskeleton
Nasiri, R., Ahmadi, A., & Ahmadabadi, M. N. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2872889 · Cited by 155
Lee, H.-J., Lee, S., Chang, W. H., Seo, K., Shim, Y., Choi, B., Ryu, G.-H., & Kim, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2664801 · Cited by 150
Autonomous exoskeleton reduces metabolic cost of human walking
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-151 · Cited by 145
Reducing the metabolic cost of running with a tethered soft exosuit
Lee, G., Kim, J., Panizzolo, F. A., Zhou, Y. M., Baker, L. M., Galiana, I., Malcolm, P., & Walsh, C. J. (2017) · Science Robotics · doi:10.1126/scirobotics.aan6708 · Cited by 143
Young, A. J., & Hargrove, L. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412461 · Cited by 142
Self-citation"Body-In-The-Loop": Optimizing Device Parameters Using Measures of Instantaneous Energetic Cost
Felt, W., Selinger, J. C., Donelan, J. M., & Remy, C. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135342 · Cited by 137
A lightweight, low-power electroadhesive clutch and spring for exoskeleton actuation
Diller, S., Majidi, C., & Collins, S. H. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487194 · Cited by 137
The Effect of Hip Assistance Levels on Human Energetic Cost Using Robotic Hip Exoskeletons
Kang, I., Hsu, H., & Young, A. J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2890896 · Cited by 135
Self-citationRobotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333984 · Cited by 134
Extrapolating Metabolic Savings in Running: Implications for Performance Predictions
Kipp, S., Kram, R., & Hoogkamer, W. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00079 · Cited by 129
Understanding Muscle Energetics in Locomotion: New Modeling and Experimental Approaches
Umberger, B. R., & Rubenson, J. (2011) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e31820d7bc5 · Cited by 126
Lv, G., Zhu, H., & Gregg, R. D. (2018) · IEEE Control Systems · doi:10.1109/mcs.2018.2866605 · Cited by 124
Norris, J. A., Granata, K. P., Mitros, M., Byrne, E. M., & Marsh, A. P. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.07.002 · Cited by 123
Delayed Output Feedback Control for Gait Assistance With a Robotic Hip Exoskeleton
Lim, B., Lee, J., Jang, J., Kim, K., Park, Y. J., Seo, K., & Shim, Y. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2913318 · Cited by 119
Young, A. J., Foss, J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00004 · Cited by 113
Self-citationMulti-joint actuation platform for lower extremity soft exosuits
Ding, Y., Galiana, I., Asbeck, A., Quinlivan, B., De Rossi, S. M. M., & Walsh, C. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907024 · Cited by 112
Reducing the energy cost of walking in older adults using a passive hip flexion device
Panizzolo, F. A., Bolgiani, C., Liddo, L. D., Annese, E., & Marcolin, G. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0599-4 · Cited by 93
Autonomous hip exoskeleton saves metabolic cost of walking uphill
Seo, K., Lee, J., & Park, Y. J. (2017) · 2017 International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2017.8009254 · Cited by 90
Khazoom, C., Veronneau, C., Bigué, J.-P. L., Grenier, J., Girard, A., & Plante, J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2924852 · Cited by 89
Young, A. J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00037 · Cited by 86
Self-citationEnergetics of Walking With a Robotic Knee Exoskeleton
MacLean, M. K., & Ferris, D. P. (2019) · Journal of Applied Biomechanics · doi:10.1123/jab.2018-0384 · Cited by 80
Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-17 · Cited by 76
Connecting the legs with a spring improves human running economy
Simpson, C. S., Welker, C. G., Uhlrich, S. D., Sketch, S. M., Jackson, R. W., Delp, S. L., Collins, S. H., Selinger, J. C., & Hawkes, E. W. (2019) · Journal of Experimental Biology · doi:10.1242/jeb.202895 · Cited by 75
Variable Stiffness Spring Actuators for Low-Energy-Cost Human Augmentation
Braun, D. J., Chalvet, V., Chong, T. H., Apte, S., & Hogan, N. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2929686 · Cited by 73
Kim, J., Heimgartner, R., Lee, G., Karavas, N. C., Perry, D., Ryan, D. L., Eckert-Erdheim, A. M., Murphy, P., Choe, D. K., Galiana, I., et al. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460474 · Cited by 67
Enhanced Control of Cortical Pyramidal Neurons With Micromagnetic Stimulation
Lee, S. W., & Fried, S. I. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2631446 · Cited by 65
Evaluating physiological signal salience for estimating metabolic energy cost from wearable sensors
Ingraham, K. A., Ferris, D. P., & Remy, C. D. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00714.2018 · Cited by 65
Autonomous Multi-Joint Soft Exosuit for Assistance with Walking Overground
Lee, S., Karavas, N. C., Quinlivan, B. T., LouiseRyan, D., Perry, D., Eckert-Erdheim, A. M., Murphy, P., Goldy, T. G., Menard, N., Athanassiu, M., et al. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460972 · Cited by 61
Exoskeletons Improve Locomotion Economy by Reducing Active Muscle Volume
Beck, O. N., Punith, L. K., Nuckols, R. W., & Sawicki, G. S. (2019) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000204 · Cited by 56
Self-citationKoller, J. R., Remy, C. D., & Ferris, D. P. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0379-6 · Cited by 54
Kim, D.-S., Lee, H.-J., Lee, S., Chang, W. H., Jang, J., Choi, B., Ryu, G.-H., & Kim, Y. (2018) · BMC Geriatrics · doi:10.1186/s12877-018-0921-1 · Cited by 53
Walking performance and economy in chronic heart failure patients pre and post exercise training
Beneke, R., & Meyer, K. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050155 · Cited by 47
Rapid energy expenditure estimation for ankle assisted and inclined loaded walking
Slade, P., Troutman, R., Kochenderfer, M. J., Collins, S. H., & Delp, S. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0535-7 · Cited by 47
Electromyography (EMG) Signal Contributions in Speed and Slope Estimation Using Robotic Exoskeletons
Kang, I., Kunapuli, P., Hsu, H., & Young, A. J. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779433 · Cited by 46
Self-citationChen, W., Wu, S., Zhou, T., & Xiong, C. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aaeefd · Cited by 45
An experimental robotic testbed for accelerated development of ankle prostheses
Caputo, J. M., & Collins, S. H. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630940 · Cited by 44
Enhancing Mobility With Quasi-Passive Variable Stiffness Exoskeletons
Sutrisno, A., & Braun, D. J. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2899753 · Cited by 44
Torque Control in Legged Locomotion
Zhang, J., Cheah, C., & Collins, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803766-9.00007-5 · Cited by 42
A flexible exoskeleton for hip assistance
Lee, Y., Roh, S.-G., Lee, M., Choi, B., Lee, J., Kim, J., Choi, H., Shim, Y., & Kim, Y.-J. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8202275 · Cited by 36
Extremum Seeking Control for Model-Free Auto-Tuning of Powered Prosthetic Legs
Kumar, S., Mohammadi, A., Quintero, D., Rezazadeh, S., Gans, N., & Gregg, R. D. (2019) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2019.2928514 · Cited by 32
Kao, P.-C., Lewis, C. L., & Ferris, D. P. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-33 · Cited by 31
Grazi, L., Crea, S., Parri, A., Lova, R. M., Micera, S., & Vitiello, N. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00071 · Cited by 31
Kao, P.-C., Lewis, C. L., & Ferris, D. P. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.024 · Cited by 26
Design of Lower-Limb Exoskeletons and Emulator Systems
Witte, K. A., & Collins, S. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00013-8 · Cited by 25
Lane, A. R., Harkey, M. S., Davis-Wilson, H. C., Luc‐Harkey, B. A., Stanley, L. E., Hackney, A. C., Blackburn, J. T., & Pietrosimone, B. (2019) · Journal of Athletic Training · doi:10.4085/1062-6050-525-17 · Cited by 18
Cited by
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Personalizing exoskeleton assistance while walking in the real world
Slade, P., Kochenderfer, M. J., Delp, S. L., & Collins, S. H. (2022) · Nature · doi:10.1038/s41586-022-05191-1 · Cited by 328
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Soft Robotic Suits: State of the Art, Core Technologies, and Open Challenges
Xiloyannis, M., Alicea, R., Georgarakis, A.-M., Haufe, F. L., Wolf, P., Masia, L., & Riener, R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3084466 · Cited by 225
“One of the key messages of Ferris’ script, i.e. to put more emphasis on the reduction of metabolic cost as a key performance metric for wearable robots, has been heard clearly by the community [148].”
BackgroundHow adaptation, training, and customization contribute to benefits from exoskeleton assistance
Poggensee, K. L., & Collins, S. H. (2021) · Science Robotics · doi:10.1126/scirobotics.abf1078 · Cited by 214
Metadata
- Authors
- Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2020-02-19
- Volume
- 17
- Issue
- 1
- Pages
- 25-25
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W3012841673
- Cited by
- 424
- References
- 95
- FWCI
- 19.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.