Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Introduction: Electrical velocimetry (EV) is a type of impedance cardiography, and is a non-invasive and continuously applicable method of cardiac output monitoring. Transthoracic echocardiography (TTE) is non-invasive but discontinuous. Methods: We compared EV with TTE in pediatric intensive care patients in a prospective single-center observational study. Simultaneous, coupled, left ventricular stroke volume measurements were performed by EV using an Aesculon® monitor and TTE (either via trans-aortic valve flow velocity time integral [EVVTI], or via M-mode [EVMM]). H 0: bias was less than 10% and the mean percentage error (MPE) was less than 30% in Bland–Altman analysis between EV and TTE. If appropriate, data were logarithmically transformed prior to Bland–Altman analysis. Results: A total of 72 patients (age: 2 days to 17 years; weight: 0.8 to 86 kg) were analyzed. Patients were divided into subgroups: organ transplantation (OTX, n =28), sepsis or organ failure (SEPSIS, n =16), neurological patients (NEURO, n =9), and preterm infants (PREM, n =26); Bias/MPE for EVVTI was 7.81%/26.16%. In the EVVTI subgroup analysis for OTX, NEURO, and SEPSIS, bias and MPE were within the limits of H 0, whereas the PREM subgroup had a bias/MPE of 39.00%/46.27%. Bias/MPE for EVMM was 8.07%/37.26% where the OTX and NEURO subgroups were within the range of H 0, but the PREM and SEPSIS subgroups were outside the range. Mechanical ventilation, non-invasive continuous positive airway pressure ventilation, body weight, and secondary abdominal closure were factors that significantly affected comparison of the methods. Conclusions: This study shows that EV is comparable with aortic flow-based TTE for pediatric patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“Agreement between the EV and TTE methods was assessed by means of Bland–Altman plots [17,18].”
MethodCecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351 · cited 6×
“A theoretical TPEV could be calculated because two imprecise CO monitoring methods (EV and TTE) were compared [19-21].”
BackgroundMethodInfluentialChew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151
Noori, S., Drabu, B., Soleymani, S., & Seri, I. (2012) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fetalneonatal-2011-301090 · Cited by 146 · cited 3×
“True precision for EV (TPEV) was calculated based on the following equation [20,21]:”
MethodResultNon-Invasive Cardiac Output Measurement in Low and Very Low Birth Weight: A Method Comparison
Grollmuss, O., & Gonzalez, P. (2014) · Frontiers in Pediatrics · doi:10.3389/fped.2014.00016 · Cited by 52
Cited by
Narula, J., Chauhan, S., Ramakrishnan, S., & Gupta, S. K. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.12.009 · Cited by 39
Effect of hemodialysis on impedance cardiography (electrical velocimetry) parameters in children
Wilken, M., Oh, J., Pinnschmidt, H. O., Singer, D., & Blohm, M. E. (2020) · Pediatric Nephrology · doi:10.1007/s00467-019-04409-1 · Cited by 8
“However, literature data [27] including our own data [19] on stroke volume measurement by EV shows correlation to reference methods depending on the individual patient groups.”
BackgroundMethodSelf-citationSumbel, L., Nagaraju, L., Ogbeifun, H., Agarwal, A., & Bhalala, U. (2022) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2022.101551 · Cited by 4
Research Progress of Noninvasive Cardiac Output Monitor (NICOTM) and Hemodynamic Monitor in Neonates
Li, F., & Dong, W. (2023) · Clinical and Experimental Obstetrics & Gynecology · doi:10.31083/j.ceog5010211 · Cited by 2
“[24] showed that EC is comparable to the aortic flow-based TTE method for pediatric patients.”
Result
Metadata
- Authors
- Blohm, M. E., Obrecht, D., Hartwich, J., Mueller, G. C., Kersten, J. F., Weil, J., & Singer, D.
- Venue
- Critical Care
- Published
- 2014-11-19
- Volume
- 18
- Issue
- 6
- Pages
- 603-603
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2148361238
- Cited by
- 63
- References
- 6
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. https://app.cochat.ai/papers/10.1186/s13054-014-0603-0
- The paper
- Blohm, M. E., Obrecht, D., Hartwich, J., Mueller, G. C., Kersten, J. F., Weil, J., & Singer, D. (2014). Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Critical Care. https://doi.org/10.1186/s13054-014-0603-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.