Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Introduction: Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the “gold standard” for arterial pressure monitoring. Nonetheless, artifacts due to inappropriate dynamic response of the fluid-filled monitoring systems may lead to clinically relevant differences between actual and displayed pressure values. We sought to analyze the incidence and causes of resonance/underdamping phenomena in patients undergoing major vascular and cardiac surgery. Methods: Arterial pressures were measured invasively and, according to the fast-flush Gardner’s test, each patient was attributed to one of two groups depending on the presence (R-group) or absence (NR-group) of resonance/underdamping. Invasive pressure values were then compared with the non-invasive ones. Results: A total of 11,610 pulses and 1,200 non-invasive blood pressure measurements were analyzed in 300 patients. Ninety-two out of 300 (30.7%) underdamping/resonance arterial signals were found. In these cases (R-group) systolic invasive blood pressure (IBP) average overestimation of non-invasive blood pressure (NIBP) was 28.5 (15.9) mmHg (P <0.0001) while in the NR-group the overestimation was 4.1(5.3) mmHg (P <0.0001). The mean IBP-NIBP difference in diastolic pressure in the R-group was −2.2 (10.6) mmHg and, in the NR-group −1.1 (5.8) mmHg. The mean arterial pressure difference was 7.4 (11.2) mmHg in the R-group and 2.3 (6.4) mmHg in the NR-group. A multivariate logistic regression identified five parameters independently associated with underdamping/resonance: polydistrectual arteriopathy (P =0.0023; OR = 2.82), history of arterial hypertension (P =0.0214; OR = 2.09), chronic obstructive pulmonary disease (P =0.198; OR = 2.61), arterial catheter diameter (20 vs. 18 gauge) (P <0.0001; OR = 0.35) and sedation (P =0.0131; OR = 0.5). The ROC curve for the maximal pressure–time ratio, showed an optimum selected cut-off point of 1.67 mmHg/msec with a specificity of 97% (95% CI: 95.13 to 99.47%) and a sensitivity of 77% (95% CI: 67.25 to 85.28%) and an area under the ROC curve by extended trapezoidal rule of 0.88. Conclusion: Physicians should be aware of the possibility that IBP can be inaccurate in a consistent number of patients due to underdamping/resonance phenomena. NIBP measurement may help to confirm/exclude the presence of this artifact avoiding inappropriate treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“96 SD of the measurement differences) [13].”
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Miller, R. D. (2005) · Cited by 1,241
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616 · cited 1×
“Moreover, the analog pressure signals were digitized using a multifunction board (Multifunction Analog and Digital Board RTI-800, Analog-Devices, Norwood, MA, USA), and recorded on a personal computer (LTE5000, Compaq, Houston, TX, USA) for fast-flush test registration and analysis [11] (Figure 1).”
MethodSelf-citationDirect Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518 · cited 6×
“N: normal Q Each patient was then assigned to one of two groups depending on the presence (R-group) or absence (NRgroup) of resonance/underdamping identified by the fast-flush test [9].”
BackgroundMethodInfluentialCavaillès, A., Brinchault-Rabin, G., Dixmier, A., Goupil, F., Gut-Gobert, C., Marchand-Adam, S., Meurice, J.-C., Morel, H., Person-Tacnet, C., Leroyer, C., et al. (2013) · European Respiratory Review · doi:10.1183/09059180.00008612 · Cited by 510 · cited 1×
“This association may be explained with the hypothesis that arterial hypertension and atherosclerosis, both associated with underdamping/resonance and frequently affecting COPD patients [19], may have been missed in the medical history.”
BackgroundAntonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466 · cited 1×
“Arterial pressure measurement represents a mandatory step in the evaluation of patients? hemodynamics because it gives primary information about the performance of the cardiovascular system and tissue perfusion [1].”
BackgroundMcDonaldʼs Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, ed. 3
Nichols, W. W., OʼRourke, M. F., & Kenney, W. L. (1991) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-199111000-00023 · Cited by 451
The left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.
Little, W. C. (1985) · Circulation Research · doi:10.1161/01.res.56.6.808 · Cited by 297
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224 · cited 12×
“As further confirmation of this, a recently published survey of blood pressure monitoring showed NIBP to be commonly used by a large number of ICU physicians in the United States [4].”
BackgroundInfluentialMonitoring Arterial Blood Pressure: What You May Not Know
McGhee, B. H., & Bridges, E. J. (2002) · Critical Care Nurse · doi:10.4037/ccn2002.22.2.60 · Cited by 189 · cited 2×
“Nonetheless, our analysis did not identify norepinephrine administration as a correlated factor [20].”
BackgroundBur, A., Herkner, H., Vlcek, M., Woisetschläger, C., Derhaschnig, U., Delle Karth, G., Laggner, A. N., & Hirschl, M. M. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000053650.12025.1a · Cited by 123 · cited 3×
“However, NIBP measurement is not continuous and, during hemodynamic instability, severe hypotension, in conditions of increased arterial stiffness and in obese patients, this technique is expected to be less accurate than the invasive one [2,4-8].”
BackgroundArterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115 · cited 2×
“However, NIBP measurement is not continuous and, during hemodynamic instability, severe hypotension, in conditions of increased arterial stiffness and in obese patients, this technique is expected to be less accurate than the invasive one [2,4-8].”
BackgroundManios, E., Vemmos, K., Tsivgoulis, G., Barlas, G., Eleni, K., Spengos, K., & Zakopoulos, N. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b083e2 · Cited by 72 · cited 1×
“In fact, the IBP-NIBP difference in NR patients was clinically irrelevant, indicating that NIBP might be considered a reliable and accurate method even in the ICU, with the exception of certain specific conditions (for example, obese patients, extreme hypotension, arrhythmias) [15,16].”
MethodAssessment of left ventricular function by pulse wave analysis in critically ill patients
Scolletta, S., Bodson, L., Donadello, K., Taccone, F. S., Devigili, A., Vincent, J., & Backer, D. D. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2861-8 · Cited by 72 · cited 1×
“contractility [23,24].”
Chatterjee, A. B., DePriest, K. L., Blair, R. A., Bowton, D. L., & Chin, R. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181fa057f · Cited by 58 · cited 3×
“However, NIBP measurement is not continuous and, during hemodynamic instability, severe hypotension, in conditions of increased arterial stiffness and in obese patients, this technique is expected to be less accurate than the invasive one [2,4-8].”
BackgroundTracking Hypotension and Dynamic Changes in Arterial Blood Pressure with Brachial Cuff Measurements
Lakhal, K., Ehrmann, S., Runge, I., Legras, A., Dequin, P., Mercier, E., Wolff, M., Regnier, B., & Boulain, T. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a8d83a · Cited by 45 · cited 3×
“Second, severe hypotension is commonly recognized as limiting the accuracy of NIBP, although recent data call this statement into question [12].”
BackgroundMethodPytte, M., Dybwik, K., Sexton, J., Straume, B., & Nielsen, E. W. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01045.x · Cited by 32 · cited 1×
“In fact, the IBP-NIBP difference in NR patients was clinically irrelevant, indicating that NIBP might be considered a reliable and accurate method even in the ICU, with the exception of certain specific conditions (for example, obese patients, extreme hypotension, arrhythmias) [15,16].”
MethodAccuracy of disposable blood pressure transducers used in the critical care setting
Bailey, R. H., Bauer, J. H., & Yanos, J. (1995) · Critical Care Medicine · doi:10.1097/00003246-199501000-00029 · Cited by 10 · cited 1×
“This concurs with existing literature [12,18].”
Cited by
How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S. (2020) · Critical Care · doi:10.1186/s13054-020-02859-w · Cited by 214
Self-citation
Metadata
- Authors
- Romagnoli, S., Ricci, Z., Quattrone, D., Tofani, L., Tujjar, O., Villa, G., Romano, S. M., & De Gaudio, A. R.
- Venue
- Critical Care
- Published
- 2014-11-30
- Volume
- 18
- Issue
- 6
- Pages
- 644-644
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2068163434
- Cited by
- 191
- References
- 25
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.