Pulse oximetry
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Pulse oximetry is universally used for monitoring patients in the critical care setting. This article updates the review on pulse oximetry that was published in 1999 in Critical Care. A summary of the recently developed multiwavelength pulse oximeters and their ability in detecting dyshemoglobins is provided. The impact of the latest signal processing techniques and reflectance technology on improving the performance of pulse oximeters during motion artifact and low perfusion conditions is critically examined. Finally, data regarding the effect of pulse oximetry on patient outcome are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rice, T. W., Wheeler, A. P., Bernard, G. R., Hayden, D. L., Schoenfeld, D. A., & Ware, L. B. (2007) · Chest · doi:10.1378/chest.07-0617 · Cited by 820
Moller, J. T., Johannessen, N. W., Espersen, K., Ravlo, O., Pedersen, B. D., Jensen, P. F., Rasmussen, N. H., Rasmussen, L. S., Pedersen, T., Cooper, J. B., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00007 · Cited by 435
Pandharipande, P. P., Shintani, A. K., Hagerman, H. E., St Jacques, P. J., Rice, T. W., Sanders, N. W., Ware, L. B., Bernard, G. R., & Ely, E. W. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819cefa9 · Cited by 309
Accuracy of pulse oximetry in the intensive care unit
Louw, A., Cracco, C., Cerf, C., Harf, A., Duvaldestin, P., Lemaire, F., & Brochard, L. (2001) · Intensive Care Medicine · doi:10.1007/s001340101064 · Cited by 308
Pulse oximetry: Analysis of theory, technology, and practice
Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01617328 · Cited by 306
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296 · cited 3×
“and in patients with sickle cell anemia [1,6,25,26].”
Self-citationPulse oximetry for perioperative monitoring
Pedersen, T., Nicholson, A., Hovhannisyan, K., Møller, A. M., Smith, A. F., & Lewis, S. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002013.pub3 · Cited by 249
Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study
Barker, S. J., Curry, J., Redford, D., & Morgan, S. (2006) · Anesthesiology · doi:10.1097/00000542-200611000-00008 · Cited by 238
Moller, J. T., Pedersen, T., Rasmussen, L. S., Jensen, P. F., Pedersen, B. D., Ravlo, O., Rasmussen, N. H., Espersen, K., Johannessen, N. W., Cooper, J. B., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00006 · Cited by 225
Principles and Practice of Intensive Care Monitoring.
(1998) · Thorax · doi:10.1136/thx.53.10.908 · Cited by 218
Cited by
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Fawzy, A., Wu, T. D., Wang, K., Robinson, M. L., Farha, J., Bradke, A., Golden, S. H., Xu, Y., & Garibaldi, B. T. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1906 · Cited by 326
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Wearable technology: role in respiratory health and disease
Aliverti, A. (2017) · Breathe · doi:10.1183/20734735.008417 · Cited by 243
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124
“Pulse oximeter devices incorporating PPG are employed to evaluate peripheral blood oxygen saturation based on the measurement of red and infrared light absorption levels, directly influenced by hemoglobin levels [4,5].”
BackgroundA review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119
Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion
Louie, A., Feiner, J. R., Bickler, P. E., Rhodes, L., Bernstein, M., & Lucero, J. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002002 · Cited by 106
Pipek, L. Z., Nascimento, R. F. V., Acencio, M. M. P., & Teixeira, L. R. (2021) · Scientific Reports · doi:10.1038/s41598-021-98453-3 · Cited by 87
Crooks, C. J., West, J., Morling, J. R., Simmonds, M., Juurlink, I., Briggs, S., Cruickshank, S., Hammond-Pears, S., Shaw, D., Card, T. R., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.03246-2021 · Cited by 68
Critical Bias in Critical Care Devices
Charpignon, M.-L., Byers, J., Cabral, S., Celi, L. A., Fernandes, C., Gallifant, J., Lough, M. E., Mlombwa, D., Moukheiber, L., Ong, B. A., et al. (2023) · Critical Care Clinics · doi:10.1016/j.ccc.2023.02.005 · Cited by 35
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth
Swamy, S. K. N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., et al. (2026) · Pediatric Research · doi:10.1038/s41390-024-03651-0 · Cited by 7
“12 Transmission mode POs function by emitting light through peripheral locations such as the fi ngers, wrist, toes, earlobes, or the foot with a detector on the opposite side to measure the light transmitted.”
Metadata
- Authors
- Jubran, A.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 272-272
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W4247285420
- Cited by
- 491
- References
- 44
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.