Pulse oximetry
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Pulse oximetry is universally used for monitoring patients in the critical care setting. This article updates the review on pulse oximetry that was published in 1999 in Critical Care. A summary of the recently developed multiwavelength pulse oximeters and their ability in detecting dyshemoglobins is provided. The impact of the latest signal processing techniques and reflectance technology on improving the performance of pulse oximeters during motion artifact and low perfusion conditions is critically examined. Finally, data regarding the effect of pulse oximetry on patient outcome are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rice, T. W., Wheeler, A. P., Bernard, G. R., Hayden, D. L., Schoenfeld, D. A., & Ware, L. B. (2007) · Chest · doi:10.1378/chest.07-0617 · Cited by 820
Moller, J. T., Johannessen, N. W., Espersen, K., Ravlo, O., Pedersen, B. D., Jensen, P. F., Rasmussen, N. H., Rasmussen, L. S., Pedersen, T., Cooper, J. B., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00007 · Cited by 435
Pandharipande, P. P., Shintani, A. K., Hagerman, H. E., St Jacques, P. J., Rice, T. W., Sanders, N. W., Ware, L. B., Bernard, G. R., & Ely, E. W. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819cefa9 · Cited by 309
Accuracy of pulse oximetry in the intensive care unit
Louw, A., Cracco, C., Cerf, C., Harf, A., Duvaldestin, P., Lemaire, F., & Brochard, L. (2001) · Intensive Care Medicine · doi:10.1007/s001340101064 · Cited by 308
Pulse oximetry: Analysis of theory, technology, and practice
Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01617328 · Cited by 306
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296 · cited 3×
“and in patients with sickle cell anemia [1,6,25,26].”
Self-citationPulse oximetry for perioperative monitoring
Pedersen, T., Nicholson, A., Hovhannisyan, K., Møller, A. M., Smith, A. F., & Lewis, S. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002013.pub3 · Cited by 249
Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study
Barker, S. J., Curry, J., Redford, D., & Morgan, S. (2006) · Anesthesiology · doi:10.1097/00000542-200611000-00008 · Cited by 238
Moller, J. T., Pedersen, T., Rasmussen, L. S., Jensen, P. F., Pedersen, B. D., Ravlo, O., Rasmussen, N. H., Espersen, K., Johannessen, N. W., Cooper, J. B., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00006 · Cited by 225
Principles and Practice of Intensive Care Monitoring.
(1998) · Thorax · doi:10.1136/thx.53.10.908 · Cited by 218
Jubran, A. (1999) · Critical Care · doi:10.1186/cc341 · Cited by 217
Self-citationPotential errors in pulse oximetry: II. Effects of changes in saturation and signal quality*
WEBB, R. K., RALSTON, A. C., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09411.x · Cited by 213
“Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models
Barker, S. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200210000-00033 · Cited by 204
The Effects of Motion on the Performance of Pulse Oximeters in Volunteers (Revised publication)
Barker, S. J., & Shah, N. K. (1997) · Anesthesiology · doi:10.1097/00000542-199701000-00014 · Cited by 195
The Effect of Motion on Pulse Oximetry and Its Clinical Significance
Petterson, M. T., Begnoche, V. L., & Graybeal, J. M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278134.47777.a5 · Cited by 176
The Effect of Nail Polish on Pulse Oximetry
Cot??, C. J., Goldstein, E. A., Fuchsman, W. H., & Hoaglin, D. C. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198807000-00013 · Cited by 172
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
The incidence of hypoxemia during surgery: evidence from two institutions
Ehrenfeld, J. M., Funk, L. M., van Schalkwyk, J., Merry, A., Sandberg, W. S., & Gawande, A. A. (2010) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-010-9366-5 · Cited by 159
Pretto, J. J., Roebuck, T., Beckert, L., & Hamilton, G. S. (2013) · Respirology · doi:10.1111/resp.12204 · Cited by 143
Perkins, G. D., McAuley, D. F., Giles, S., Routledge, H., & Gao, F. (2003) · Critical Care · doi:10.1186/cc2339 · Cited by 136
The Pulse Oximeter: Applications and Limitations—An Analysis of 2000 Incident Reports
Runciman, W. B., Webb, R. K., Barker, L., & Currie, M. (1993) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9302100509 · Cited by 122
Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
Hinkelbein, J., Genzwuerker, H. V., Sogl, R., & Fiedler, F. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2006.06.024 · Cited by 100
Touger, M., Birnbaum, A. J., Wang, J., Chou, K., Pearson, D., & Bijur, P. E. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.03.041 · Cited by 100
The desaturation response time of finger pulse oximeters during mild hypothermia*
MacLeod, D. B., Cortinez, L. I., Keifer, J. C., Cameron, D., Wright, D. R., White, W. D., Moretti, E. W., Radulescu, L. R., & Somma, J. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2004.04033.x · Cited by 98 · cited 1×
“The forehead probe monitors O2 saturation from the supraorbital artery in which blood flow is abundant and is less likely to be affected by vasoconstriction than is a peripheral artery [17].”
CLAYTON, D. G., WEBB, R. K., RALSTON, A. C., DUTHIE, D., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb11492.x · Cited by 90
Clinical Evaluation of a Prototype Motion Artifact Resistant Pulse Oximeter in the Recovery Room
Dumas, C., Wahr, J. A., & Tremper, K. K. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199608000-00012 · Cited by 89
Schallom, L., Sona, C. S., McSweeney, M., & Mazuski, J. E. (2007) · Heart & Lung · doi:10.1016/j.hrtlng.2006.07.007 · Cited by 75
Evaluation of a New Pulse Oximeter Sensor
Fernandez, M., Burns, K., Calhoun, B., George, S., Martin, B., & Weaver, C. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.2.146 · Cited by 66
Postoperative Hypoxemia: Common, Undetected, and Unsuspected After Bariatric Surgery
Gallagher, S. F., Haines, K., Osterlund, L. G., Mullen, M., & Downs, J. B. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2009.09.003 · Cited by 61
Accuracy of Carboxyhemoglobin Detection by Pulse CO-Oximetry During Hypoxemia
Feiner, J., Rollins, M. D., Sall, J. W., Eilers, H., Au, P., & Bickler, P. E. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31828610a0 · Cited by 55
Ochroch, E. A., Russell, M. W., Hanson, W. C., Devine, G. A., Cucchiara, A. J., Weiner, M. G., & Schwartz, S. J. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000195583.76486.c4 · Cited by 55
Does Ambient Light Affect the Accuracy of Pulse Oximetry?
Fluck, R. R., Schroeder, C., Frani, G., Kropf, B., & Engbretson, B. (2003) · Respiratory Care · doi:10.4187/respcare.03480677 · Cited by 55
Shah, A. J., & Shelley, K. H. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9428-7 · Cited by 49
Forehead oximetry in critically ill patients: the case for a new monitoring site
Branson, R. D., & Mannheimer, P. D. (2004) · Respiratory Care Clinics · doi:10.1016/j.rcc.2004.04.003 · Cited by 48
Emergency Department Management of Suspected Carbon Monoxide Poisoning: Role of Pulse CO-Oximetry
Sebbane, M., Claret, P., Mercier, G., Lefebvre, S., Théry, R., Dumont, R., Maillé, M., Richard, J.-P., Eledjam, J., & Coussaye, J.-E. D. L. (2013) · Respiratory Care · doi:10.4187/respcare.02313 · Cited by 47
Accuracy of pulse oximeters: the European multi-center trial.
Wouters, P. F., Gehring, H., Meyfroidt, G., Ponz, L., Gil-Rodriguez, J., Hornberger, C., Bonk, R., Frankenberger, H., Benekos, K., Valais, J., et al. (2002) · PubMed · Cited by 46
Comber, J. T., & Lopez, B. L. (1996) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(96)90005-4 · Cited by 45
Choi, S. J., AHN, H. J., Yang, M., Kim, C. S., Sim, W.-S., KIM, J. A., Kang, J. G., KIM, J. K., & Kang, J. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02101.x · Cited by 45
Response Time of Pulse Oximeters Assessed Using Acute Decompression
Young, D., Jewkes, C., SPITTAL, M. J., Blogg, C. E., Weissman, J., & Gradwell, D. P. (1992) · Anesthesia & Analgesia · doi:10.1213/00000539-199202000-00003 · Cited by 38
Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room
Leyssius, A. T. V. R., & Kalkman, C. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.4.460 · Cited by 33
Knowledge of Pulse Oximetry Among Critical Care Nurses
Giuliano, K. K., & Liu, L. M. (2006) · Dimensions of Critical Care Nursing · doi:10.1097/00003465-200601000-00013 · Cited by 28
Tripathi, R. S., Blum, J. M., Rosenberg, A. L., & Tremper, K. K. (2010) · Journal of Critical Care · doi:10.1016/j.jcrc.2010.04.009 · Cited by 22
Hodgson, C. L., Tuxen, D. V., Holland, A. E., & Keating, J. L. (2009) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0903700620 · Cited by 13
Next-generation pulse oximetry.
(2003) · PubMed · Cited by 3
Cited by
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Fawzy, A., Wu, T. D., Wang, K., Robinson, M. L., Farha, J., Bradke, A., Golden, S. H., Xu, Y., & Garibaldi, B. T. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1906 · Cited by 326
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124
“Pulse oximeter devices incorporating PPG are employed to evaluate peripheral blood oxygen saturation based on the measurement of red and infrared light absorption levels, directly influenced by hemoglobin levels [4,5].”
Background
Metadata
- Authors
- Jubran, A.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 272-272
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W4247285420
- Cited by
- 491
- References
- 44
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.