Abstract

The large-scale popularization of electric vehicles (EVs) brings the potential for grid frequency regulation. Considering the characteristics of fast response and adjustment of EVs, two control strategies of automatic generation control (AGC) with EVs are proposed responding to two high frequency regulating signals extracted from area control error (ACE) and area regulation requirement (ARR) by a digital filter, respectively. In order to dispatch regulation task to EVs, the capacity of regulation is calculated based on maximum V2G power and the present V2G power of EVs. Finally, simulations based on a two-area interconnected power system show that the proposed approaches can significantly suppress frequency deviation and reduce the active power output of traditional generation units.

Overview

CoChat Summary

TL;DR

The paper proposes two real-time V2G control strategies that dispatch high-frequency components of ACE or ARR to EVs for AGC frequency regulation, with EV regulation capacity calculated from maximum and present V2G power. Simulations on a two-area interconnected system show both strategies reduce frequency deviation, ACE, and traditional generation output, with the ARR-based strategy generally performing better than the ACE-based strategy.

Key findings

  • In area A, frequency deviation RMS fell from 0.0575 Hz (CS0, no EVs) to 0.0423 Hz with H-ACE (CS1) and 0.0405 Hz with H-ARR (CS2); max/min also improved (CS0: 0.2132/−0.2719 Hz; CS1: 0.1696/−0.2379 Hz; CS2: 0.1654/−0.2365 Hz).
  • ACE RMS in area A fell from 232 MW (CS0) to 172 MW (CS1) and 163 MW (CS2); max/min improved from 846/−1131 MW to 687/−971 MW (CS1) and 693/−966 MW (CS2).
  • Traditional generation output RMS fell from 126.75 MW (CS0) to 104.29 MW (CS1) and 90.64 MW (CS2); min output improved from −560.56 MW to −476.70 MW (CS1) and −428.99 MW (CS2).
  • CS1 caused higher EV power mileage than CS2, indicating greater battery influence; CS2 achieved better regulation and reduced generation output more. CS1 maintained battery SOC at the plug-in level during regulation and reached expected SOC after regulation; CS2 deviated initially but met charging demand before departure.

Methods

  • Proposed two real-time closed-loop V2G control strategies for AGC: high-frequency components of ACE (H-ACE/CS1) and ARR (H-ARR/CS2) extracted by a digital high-pass filter; hierarchical dispatch from control center to EV aggregator to charging stations, with EV capacity for regulation up/down calculated from maximum V2G power plus/minus present V2G power.
  • Simulated a two-area interconnected power system with EVs integrated into area A; the EV aggregator had 100 charging stations, each managing 500 EVs; battery capacity 32 kWh, maximum charging/discharging power 7 kW, SOC limits 0.9/0.2; plug-in/out times, initial SOC, and expected SOC were normal distributions sampled by Latin Hypercube Sampling.
  • Compared CS0 (no EV participation), CS1 (H-ACE), and CS2 (H-ARR) using frequency quality, ACE quality, traditional generation output, EV power mileage, and battery SOC.

Limitations

  • Stated limitations: Not stated in the paper.
  • Evident: The evaluation is simulation-based on a two-area interconnected power system and an EV aggregator model, not field deployment or real fleet data.
  • Evident: Battery impact/SOC analysis is demonstrated with only one EV for clarity, and data availability states “Please contact author for data requests”; no explicit sensitivity or robustness analysis is reported.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s41601-018-0085-1

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Hierarchical control of EVs
Fig. 1 Hierarchical control of EVsCC-BY · From the PDF
Image 2
CC-BY · From the PDF
Fig. 3 ACE and ARR signals for regulation
Fig. 3 ACE and ARR signals for regulationCC-BY · From the PDF
Fig. 4 The control loop with high-frequency components of ACE
Fig. 4 The control loop with high-frequency components of ACECC-BY · From the PDF
Fig. 5 The control loop with high-frequency components of ARR
Fig. 5 The control loop with high-frequency components of ARRCC-BY · From the PDF
Fig. 6 Available capacity of an EV for regulation
Fig. 6 Available capacity of an EV for regulationCC-BY · From the PDF
Image 7
CC-BY · From the PDF
Image 8
CC-BY · From the PDF
Fig. 7 A two-area interconnected power system
Fig. 7 A two-area interconnected power systemCC-BY · From the PDF
Fig. 8 Load fluctuation in a time series with 1 s intervals
Fig. 8 Load fluctuation in a time series with 1 s intervalsCC-BY · From the PDF
Fig. 9 Random integration and departure of EVs in a charging station
Fig. 9 Random integration and departure of EVs in a charging stationCC-BY · From the PDF
Fig. 10 The dispatch of H-ACE within the capacity of EVs for regulation
Fig. 10 The dispatch of H-ACE within the capacity of EVs for regulationCC-BY · From the PDF
Fig. 11 The dispatch of H-ARR within the capacity of EVs for regulation
Fig. 11 The dispatch of H-ARR within the capacity of EVs for regulationCC-BY · From the PDF
Fig. 12 The power mileages of an EV for CS1 and CS2
Fig. 12 The power mileages of an EV for CS1 and CS2CC-BY · From the PDF
Fig. 13 Real-time battery SOC levels of an EV for CS1 and CS2
Fig. 13 Real-time battery SOC levels of an EV for CS1 and CS2CC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 1 Not valid · 3 Not checked · 17 Own results and interpretations

4 more claims

Create a free account to see all 21 claims and to verify the 3 references still open.

See all claims — free account
  • It may state two separate claims as one. 10
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 4

Create a free account to see these claims.

Citations

Cites

Show all 20 references

Research works printed but not linked: 1

  1. Hu, Z., Xie, X., Fang, F., Zhang, J., & Song, Y. (2014). Research on automatic generation control strategy incorporating energy storage resources[J]. Proc CSEE, 34(29), 5080-5087.

Cited by

Metadata

Authors
Liu, H., Huang, K., Yang, Y., Wei, H., & Ma, S.
Affiliations
  • Guangxi University (CN)
  • China Electric Power Research Institute (CN)
Corresponding author
Liu, H.
Venue
Protection and Control of Modern Power Systems
Published
2018-05-21
Volume
3
Issue
1
Pages
13
ISSN
  • 2367-0983 (ISSN-L)
  • 2367-2617
OpenAlex
W2805550437
Cited by
90
References
18
Citations by year
2026: 5 · 2025: 9 · 2024: 2 · 2023: 14 · 2022: 19 · 2021: 11 · 2020: 14 · 2019: 14 · 2018: 2
FWCI
3.61
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0 (tdm)
Locations
Protection and Control of Modern Power Systems (publishedVersion, cc-by)
Funders
Sino-US international Science and Technology Cooperation Project (2016YFE0105300)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Vehicles and Infrastructure
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
Keywords
vehicle-to-grid, electric vehicles, frequency regulation, automatic generation control, area control error, digital filters, two-area power system

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-25, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-25 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.