Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Objective: To provide a practical guide to appropriate statistical analysis of a reliability study using real-time ultrasound for measuring muscle size as an example. Design: Inter-rater and intra-rater (between-scans and between-days) reliability. Subjects: Ten normal subjects (five male) aged 22–58 years. Method: The cross-sectional area (CSA) of the anterior tibial muscle group was measured using real-time ultrasonography. Main outcome measures: Intraclass correlation coefficients (ICCs) and the 95% confidence interval (CI) for the ICCs, and Bland and Altman method for assessing agreement, which includes calculation of the mean difference between measures ( d), the 95% CI for d, the standard deviation of the differences (SD diff), the 95% limits of agreement and a reliability coefficient. Results: Inter-rater reliability was high, ICC (3,1) was 0.92 with a 95% CI of 0.72 → 0.98. There was reasonable agreement between measures on the Bland and Altman test, as d was -0.63 cm 2, the 95% CI for d was -1.4 → 0.14 cm 2, the SD diff was 1.08 cm 2, the 95% limits of agreement -2.73 → 1.53 cm 2 and the reliability coefficient was 2.4. Between-scans repeatability was high, ICCs (1,1) were 0.94 and 0.93 with 95% CIs of 0.8 → 0.99 and 0.75 → 0.98, for days 1 and 2 respectively. Measures showed good agreement on the Bland and Altman test: d for day 1 was 0.15 cm 2 and for day 2 it was -0.32 cm 2, the 95% CIs for d were -0.51 → 0.81 cm 2 for day 1 and -0.98 → 0.34 cm 2 for day 2; SD diff was 0.93 cm 2 for both days, the 95% limits of agreement were -1.71 → 2.01 cm 2 for day 1 and -2.18 → 1.54 cm 2 for day 2; the reliability coefficient was 1.80 for day 1 and 1.88 for day 2. The between-days ICC (1,2) was 0.92 and the 95% CI 0.69 0.98. The d was -0.98 cm 2, the SD diff was 1.25 cm 2 with 95% limits of agreement of -3.48 → 1.52 cm 2 and the reliability coefficient 2.8. The 95% CI for d(-1.88 → -0.08 cm 2) and the distribution graph showed a bias towards a larger measurement on day 2. Conclusions: The ICC and Bland and Altman tests are appropriate for analysis of reliability studies of similar design to that described, but neither test alone provides sufficient information and it is recommended that both are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Health Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
The Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
The Intraclass Correlation Coefficient as a Measure of Reliability
Bartko, J. J. (1966) · Psychological Reports · doi:10.2466/pr0.1966.19.1.3 · Cited by 2,299
An Introduction to Medical Statistics.
(1931) · Journal of the American Medical Association · doi:10.1001/jama.1931.02730150055037 · Cited by 2,084
Statistical methods for assessing observer variability in clinical measures.
Brennan, P., & Silman, A. (1992) · BMJ · doi:10.1136/bmj.304.6840.1491 · Cited by 985
Normative Values for Isometric Muscle Force Measurements Obtained With Hand-held Dynamometers
Andrews, A. W., Thomas, M. W., & Bohannon, R. W. (1996) · Physical Therapy · doi:10.1093/ptj/76.3.248 · Cited by 705
Cited by
RELIABILITY OF GAIT PERFORMANCE TESTS IN MEN AND WOMEN WITH HEMIPARESIS AFTER STROKE
Lexell, J., Flansbjer, U.-B., Holmbäck, A. M., Downham, D., & Patten, C. (2005) · Journal of Rehabilitation Medicine · doi:10.1080/16501970410017215 · Cited by 1,242
Smallest real difference, a link between reproducibility and responsiveness
Beckerman, H., Roebroeck, M. E., Lankhorst, G. J., Becher, J. G., Bezemer, P. D., & Verbeek, A. L. M. (2001) · Quality of Life Research · doi:10.1023/a:1013138911638 · Cited by 857
Reliability: what is it, and how is it measured?
Bruton, A., Conway, J. H., & Holgate, S. T. (2000) · Physiotherapy · doi:10.1016/s0031-9406(05)61211-4 · Cited by 763
Chesterton, L. S., Sim, J., Wright, C. C., & Foster, N. E. (2007) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e318154b6ae · Cited by 691
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
How to Assess the Reliability of Measurements in Rehabilitation
Lexell, J. E., & Downham, D. Y. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000176452.17771.20 · Cited by 627
van der Lee, J. H., de Groot, V., Beckerman, H., Wagenaar, R. C., Lankhorst, G. J., & Bouter, L. M. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.18668 · Cited by 500
Ultrasonographic assessment of human skeletal muscle size
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0961-9 · Cited by 489
The Case for Using the Repeatability Coefficient When Calculating Test–Retest Reliability
Vaz, S., Falkmer, T., Passmore, A. E., Parsons, R., & Andreou, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073990 · Cited by 475
Reliability of conditioned pain modulation: a systematic review
Kennedy, D. L., Kemp, H. I., Ridout, D., Yarnitsky, D., & Rice, A. S. C. (2016) · Pain · doi:10.1097/j.pain.0000000000000689 · Cited by 456
“Although there is lack of consensus in the appropriate analysis and reporting of reliability for measures which produce continuous data, as does CPM, there is growing evidence to support the use of the intraclass correlation coefficient (ICC) which reflects both the degree of association and agreement among ratings.(3…”
BackgroundMethodThe reliability and validity of ultrasound to quantify muscles in older adults: A systematic review
Nijholt, W., Scafoglieri, A., Jager‐Wittenaar, H., Hobbelen, J. S. M., & van der Schans, C. P. (2017) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.12210 · Cited by 459
Sullivan, K. J., Tilson, J. K., Cen, S. Y., Rose, D. K., Hershberg, J., Correa, A., Gallichio, J., McLeod, M., Moore, C., Wu, S. S., et al. (2011) · Stroke · doi:10.1161/strokeaha.110.592766 · Cited by 445
Stop using the Ashworth Scale for the assessment of spasticity
Fleuren, J. F. M., Voerman, G. E., Erren-Wolters, C. V., Snoek, G. J., Rietman, J. S., Hermens, H. J., & Nene, A. V. (2010) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.177071 · Cited by 428
The relationship between EMG and change in thickness of transversus abdominis
McMeeken, J. M., Beith, I. D., Newham, D. J., Milligan, P., & Critchley, D. J. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.007 · Cited by 419
Core stability exercises on and off a Swiss ball
Marshall, P. W., & Murphy, B. A. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.05.004 · Cited by 413
Evaluation of the modified fatigue impact scale in four different European countries
Kos, D., Kerckhofs, E., Carrea, I., Verza, R., Ramos, M., & Jansa, J. (2005) · Multiple Sclerosis Journal · doi:10.1191/1352458505ms1117oa · Cited by 381
A systematic review of the Tardieu Scale for the measurement of spasticity
Haugh, A. B., Pandyan, A. D., & Johnson, G. R. (2006) · Disability and Rehabilitation · doi:10.1080/09638280500404305 · Cited by 351
Between-Session Reliability of Four Hop Tests and the Agility T-Test
Munro, A. G., & Herrington, L. C. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181d83335 · Cited by 328
How Active Are People With Stroke?: Use of Accelerometers to Assess Physical Activity
Rand, D., Eng, J. J., Tang, P.-F., Jeng, J.-S., & Hung, C. (2009) · Stroke · doi:10.1161/strokeaha.108.523621 · Cited by 325
Psychometric properties of the impact on Participation and Autonomy Questionnaire
Cardol, M., de Haan, R. J., de Jong, B. A., van den Bos, G. A. M., & de Groot, I. J. M. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.18218 · Cited by 321
Chelly, M. S., Fathloun, M., Cherif, N., Amar, M. B., Tabka, Z., & Van Praagh, E. (2009) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b86c40 · Cited by 313
Smidt, N., van der Windt, D. A., Assendelft, W. J., Mourits, A. J., Devillé, W. L., de Winter, A. F., & Bouter, L. M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.33728 · Cited by 304
Marshall, P., & Murphy, B. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00027-0 · Cited by 292
Wagner, J. M., Rhodes, J. A., & Patten, C. (2008) · Physical Therapy · doi:10.2522/ptj.20070255 · Cited by 280
Reliability and Validity of the Dynamic Gait Index in Persons With Chronic Stroke
Jonsdottir, J., & Cattaneo, D. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.08.109 · Cited by 276
Munro, A., Herrington, L., & Carolan, M. (2012) · Journal of Sport Rehabilitation · doi:10.1123/jsr.21.1.7 · Cited by 265
Chelly, M. S., Ghenem, M. A., Abid, K., Hermassi, S., Tabka, Z., & Shephard, R. J. (2010) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181e2728f · Cited by 260
Statistics in medical journals: some recent trends
Altman, D. G. (2000) · Statistics in Medicine · doi:10.1002/1097-0258(20001215)19:23<3275::aid-sim626>3.0.co;2-m · Cited by 254
Rehabilitative Ultrasound Imaging: Understanding the Technology and Its Applications
Whittaker, J. L., Teyhen, D. S., Elliott, J. M., Cook, K., Langevin, H. M., Dahl, H. H., & Stokes, M. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2350 · Cited by 250
Self-citationAbdominal muscle size and symmetry in normal subjects
Rankin, G., Stokes, M., & Newham, D. J. (2006) · Muscle & Nerve · doi:10.1002/mus.20589 · Cited by 246
Self-citationBetween-session reliability of the star excursion balance test
Munro, A. G., & Herrington, L. C. (2010) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2010.07.002 · Cited by 240
Padulo, J., Oliva, F., Frizziero, A., & Maffulli, N. (2013) · PubMed · doi:10.11138/mltj/2013.3.4.250 · Cited by 239
Bohannon, R. W. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318234e59f · Cited by 231
“Although several different statistics can be used to describe the reliability of interval or ratio measures such as time to complete sit-to-stands, the intraclass correlation coefficient (ICC) is probably the most widely advocated (13,20).”
BackgroundReliability of four scales on balance disorders in persons with multiple sclerosis
Cattaneo, D., Jonsdottir, J., & Repetti, S. (2007) · Disability and Rehabilitation · doi:10.1080/09638280701191859 · Cited by 229
“In that way raters are conceived as being a random selection from among all possible raters, and subjects are conceived as being a random factor too [16].”
BackgroundConradsson, M., Lundin-Olsson, L., Lindelöf, N., Littbrand, H., Malmqvist, L., Gustafson, Y., & Rosendahl, E. (2007) · Physical Therapy · doi:10.2522/ptj.20060343 · Cited by 221
Stokes, M., Rankin, G., & Newham, D. J. (2005) · Manual Therapy · doi:10.1016/j.math.2004.08.013 · Cited by 219
Self-citationDeathe, A. B., & Miller, W. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.7.626 · Cited by 215
Sensory impairments in quiet standing in subjects with multiple sclerosis
Cattaneo, D., & Jonsdottir, J. (2009) · Multiple Sclerosis Journal · doi:10.1177/1352458508096874 · Cited by 214
“Intraclass Correlation Coefficient [21] (ICC2,1) and the Bland Altman method [22] were used to assess reliability.”
MethodGrafton, K. V., Foster, N. E., & Wright, C. C. (2005) · The Clinical Journal of Pain · doi:10.1097/00002508-200501000-00009 · Cited by 199
“A disadvantage of the ICC is that it is a “unitless” value, giving no indication of the actual measurement range or biases, and so it is difficult to interpret clinically.(41,45) The standard error of measurement (SEM) is the standard deviation of the measurement error and is easier to interpret clinically, as it is e…”
BackgroundMethodGreen, J., & Young, J. (2001) · Disability and Rehabilitation · doi:10.1080/09638280110045382 · Cited by 197
Ahtiainen, J. P., Hoffren, M., Hulmi, J. J., Pietikäinen, M., Mero, A. A., Avela, J., & Häkkinen, K. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1211-6 · Cited by 177
“Validity of the US measurements against measurements obtained using MRI were analyzed with an ICC, using a two-way random effects model (absolute agreement definition) ( Rankin and Stokes 1998 ).”
MethodKuring, J. K., Mathias, J. L., & Ward, L. (2018) · Neuropsychology Review · doi:10.1007/s11065-018-9396-2 · Cited by 173
Persson, A., Brogårdh, C., & Sjölund, B. (2004) · Journal of Rehabilitation Medicine · doi:10.1080/16501970310015218 · Cited by 173
“ICC 2,1 uses a two-way ANOVA model where we consider the raters to be randomly selected from a population of raters, i.e. a random factor ( 34 ).”
MethodMeasuring participation in children with disabilities using the Assessment of Life Habits
Noreau, L., Lepage, C., Boissiere, L., Picard, R., Fougeyrollas, P., Mathieu, J., Desmarais, G., & Nadeau, L. (2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.00666.x · Cited by 167
Dückelmann, A. M., Bamberg, C., Michaelis, S. A. M., Lange, J., Nonnenmacher, A., Dudenhausen, J. W., & Kalache, K. D. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7521 · Cited by 167
Lim, L. I. I. K., van Wegen, E. E. H., de Goede, C. J. T., Jones, D., Rochester, L., Hetherington, V., Nieuwboer, A., Willems, A. M., & Kwakkel, G. (2005) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2004.06.003 · Cited by 166
“The use of ICC’s and Bland and Altman method gives complementary information as shown by Rankin and Stokes [26].”
MethodRietberg, M. B., Van Wegen, E. E. H., & Kwakkel, G. (2010) · Disability and Rehabilitation · doi:10.3109/09638281003734458 · Cited by 165
“All ICCs p5 0.001. of the patients’ fatigue, and that use of a onedimensional assessment would be a shortcoming in comprehensive fatigue assessment.”
MethodInfluentialReliability of gait speed measured by a timed walking test in patients one year after stroke
Green, J., Forster, A., & Young, J. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr495oa · Cited by 164
Sarwal, A., Parry, S. M., Berry, M. J., Hsu, F.-C., Lewis, M. T., Justus, N. W., Morris, P. E., Denehy, L., Berney, S., Dhar, S., et al. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.7.1191 · Cited by 158
Endleman, I., & Critchley, D. J. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.04.025 · Cited by 126
Interrater and Intrarater Reliability of the Beighton Score: A Systematic Review
Bockhorn, L. N., Vera, A. M., Dong, D., Delgado, D. A., Varner, K. E., & Harris, J. D. (2021) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967120968099 · Cited by 85
“Cooper (2018)(15) 50, 49 (22-60), 56, community members VG NS 1 wk VG 5 item þ goniometer 1 NS NS NS A”
BackgroundA latent state‐trait analysis of interoceptive accuracy
Wittkamp, M. F., Bertsch, K., Vögele, C., & Schulz, A. (2018) · Psychophysiology · doi:10.1111/psyp.13055 · Cited by 72
Concurrent validity of accelerometry to measure gait in Parkinsons Disease
Lord, S., Rochester, L., Baker, K., & Nieuwboer, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.04.001 · Cited by 69
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
“Using both CV and ICC gives good insight into the magnitude of (dis)agreement between the PAM’s (Rankin & Stokes, 1998).”
MethodInfluentialA new simple technique for 3-dimensional sonographic assessment of the pelvic floor muscles
Youssef, A., Montaguti, E., Sanlorenzo, O., Cariello, L., Awad, E. E., Pacella, G., Ghi, T., Pilu, G., & Rizzo, N. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.1.65 · Cited by 48
Administering the MADRS by telephone or face-to-face: a validity study.
Hermens, M. L., Adèr, H. J., van Hout, H. P., Terluin, B., van Dyck, R., & de Haan, M. (2006) · Annals of General Psychiatry · doi:10.1186/1744-859x-5-3 · Cited by 47
“The 'limits of agreement' are calculated (mean difference ± 2*SD) defining the range that contains 95% of all differences [19,22,23].”
BackgroundTissue Doppler imaging for detecting onset of muscle activity
Pulkovski, N., Schenk, P., Maffiuletti, N. A., & Mannion, A. F. (2008) · Muscle & Nerve · doi:10.1002/mus.20996 · Cited by 42
Jones, N. W., Raine-Fenning, N. J., Mousa, H. A., Bradley, E., & Bugg, G. J. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.11.018 · Cited by 32
“Systematic bias between the two measurements was determined by calculating the 95% confidence interval for the mean difference, which is obtained by calculating the mean difference 6 t standard error, where t is generated from tables of the t distribution with n-1 degrees of freedom (Rankin and Stokes 1998).”
MethodBeltran-Alacreu, H., López-de-Uralde-Villanueva, I., Paris-Alemany, A., Angulo-Díaz-Parreño, S., & La Touche, R. (2014) · Journal of Physical Therapy Science · doi:10.1589/jpts.26.915 · Cited by 30
Metadata
- Authors
- Rankin, G., & Stokes, M.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 1998-06
- Volume
- 12
- Issue
- 3
- Pages
- 187-199
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2144523708
- Cited by
- 856
- References
- 21
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.