CoChat

Tissue distribution of radioactivity following intranasal administration of radioactive microspheres

Eyles, J E, Spiers, I D, Williamson, E D, Alpar, H O · 2001 · Journal of Pharmacy and Pharmacology
Cited by 48

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The aim of this study was to increase understanding of the kinetics of microparticle distribution and elimination following intranasal application. To do this we investigated the in-vivo distribution of radioactivity following intranasal instillation of scandium-46 labelled styrene-divinyl benzene 7-μm-diameter microspheres. Groups of BALB/c mice received 0.250 mg (47.5 kBq) particles suspended in either 50-μl or 10-μl volumes of phosphate buffered saline. The in-vivo distribution of radioactivity was influenced by the volume of liquid that was used to instil the microsphere suspension. Comparatively large (50 μl) administration vehicle volumes resulted in substantial bronchopulmonary deposition (∼ 50% of administered dose). Intranasal instillation of microspheres suspended in 10-μl volumes tended to restrict particle deposition initially to the nasal cavity. For both administration vehicle volumes tested, the radioactivity per unit mass of excised nasal-associated lymphoid tissue (NALT) was found to be consistently elevated relative to other tissues. This corroborates the findings of other workers who have previously identified NALT as an active site of microparticle accumulation following intranasal application. Elimination via the alimentary canal was the principal fate of intranasally applied radiolabeled material. No significant concentration of radioactivity within excised gut-associated lymphoid tissue (GALT) (Peyer's patches) was noted. At latter time points we observed, in mice that received the 50-μl volume particle suspension nasally, accumulation of potentially relevant quantities of radioactivity in the liver (0.3% after 576 h) and spleen (0.04% after 576 h). Thus, our data corroborate the notion that epithelial membranes in the lung are probably less exclusive to the entry of microparticulates into systemic compartments than are those mucosae in the gastrointestinal tract or nasopharynx. This effect may contribute to the effectiveness of pulmonary delivered antigen-loaded microparticles as humoral immunogens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1211/0022357011775929

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Eyles, J. E., Spiers, I. D., Williamson, E. D., & Alpar, H. O.
Venue
Journal of Pharmacy and Pharmacology
Published
2001-05-01
Volume
53
Issue
5
Pages
601-607
ISSN
  • 0022-3573 (ISSN-L)
  • 2042-7158
OpenAlex
W2029604938
Cited by
48
References
1
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.