Predicting Fluid Responsiveness in Children: A Systematic Review
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Administration of fluid to improve cardiac output is the mainstay of hemodynamic resuscitation. Not all patients respond to fluid therapy, and excessive fluid administration is harmful. Predicting fluid responsiveness can be challenging, particularly in children. Numerous hemodynamic variables have been proposed as predictors of fluid responsiveness. Dynamic variables based on the heart-lung interaction appear to be excellent predictors of fluid responsiveness in adults, but there is no consensus on their usefulness in children. METHODS: We systematically reviewed the current evidence for predictors of fluid responsiveness in children. A systematic search was performed using PubMed (1947-2013) and EMBASE (1974-2013). Search terms included fluid, volume, response, respond, challenge, bolus, load, predict, and guide. Results were limited to studies involving pediatric subjects (infant, child, and adolescent). Extraction of data was performed independently by 2 authors using predefined data fields, including study quality indicators. Any variable with an area under the receiver operating characteristic curve that was significantly above 0.5 was considered predictive. RESULTS: Twelve studies involving 501 fluid boluses in 438 pediatric patients (age range 1 day to 17.8 years) were included. Twenty-four variables were investigated. The only variable shown in multiple studies to be predictive was respiratory variation in aortic blood flow peak velocity (5 studies). Stroke volume index, stroke distance variation, and change in cardiac index (and stroke volume) induced by passive leg raising were found to be predictive in single studies only. Static variables based on heart rate, systolic arterial blood pressure, preload (central venous pressure, pulmonary artery occlusion pressure), thermodilution (global end diastolic volume index), ultrasound dilution (active circulation volume, central blood volume, total end diastolic volume, total ejection fraction), echocardiography (left ventricular end diastolic area), and Doppler (stroke volume index, corrected flow time) did not predict fluid responsiveness in children. Dynamic variables based on arterial blood pressure (systolic pressure variation, pulse pressure variation and stroke volume variation, difference between maximal or minimal systolic arterial blood pressure and systolic pressure at end-expiratory pause) and plethysmography (pulse oximeter plethysmograph amplitude variation) were also not predictive. There were contradicting results for plethymograph variation index and inferior vena cava diameter variation. CONCLUSIONS: Respiratory variation in aortic blood flow peak velocity was the only variable shown to predict fluid responsiveness in children. Static variables did not predict fluid responsiveness in children, which was consistent with evidence in adults. Dynamic variables based on arterial blood pressure did not predict fluid responsiveness in children, but the evidence for dynamic variables based on plethysmography was inconclusive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Boyd, J. H., Forbes, J., Nakada, T.-A., Walley, K. R., & Russell, J. A. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181feeb15 · Cited by 1,517
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Leimbach, W. N., Wallin, B. G., Victor, R. G., Aylward, P. E., Sundlöf, G., & Mark, A. L. (1986) · Circulation · doi:10.1161/01.cir.73.5.913 · Cited by 812
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Han, Y. Y., Carcillo, J. A., Dragotta, M. A., Bills, D. M., Watson, R. S., Westerman, M. E., & Orr, R. A. (2003) · Pediatrics · doi:10.1542/peds.112.4.793 · Cited by 642
Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462
The Importance of Fluid Management in Acute Lung Injury Secondary to Septic Shock
Murphy, C. V., Schramm, G. E., Doherty, J. A., Reichley, R. M., Gajic, O., Afessa, B., Micek, S. T., & Kollef, M. H. (2009) · Chest · doi:10.1378/chest.08-2706 · Cited by 441
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424
Perel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 403
Cavallaro, F., Sandroni, C., Marano, C., La Torre, G., Mannocci, A., De Waure, C., Bello, G., Maviglia, R., & Antonelli, M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1929-y · Cited by 386
Cannesson, M. P., Desebbe, O., Rosamel, P., Delannoy, B., Robin, J., Bastien, O. H., & Lehot, J.-J. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen133 · Cited by 377
Self-citationBoulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Rosenberg, A. L., Dechert, R. E., Park, P. K., Bartlett, R. H., & NIH NHLBI ARDS Network (2009) · Journal of Intensive Care Medicine · doi:10.1177/0885066608329850 · Cited by 331
Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients
Feissel, M., Teboul, J., Merlani, P. G., Badie, J. C., Faller, J.-P., & Bendjelid, K. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0602-6 · Cited by 300
Abbas, S. M., & Hill, A. G. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05233.x · Cited by 296
Fredriks, A. M. (2005) · Archives of Disease in Childhood · doi:10.1136/adc.2004.050799 · Cited by 283
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224
Cannesson, M., Attof, Y., Rosamel, P., Desebbe, O., Joseph, P., Metton, O., Bastien, O., & Lehot, J.-J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267593.72744.20 · Cited by 216
Self-citationCannesson, M., Musard, H., Desebbe, O., Boucau, C., Simon, R., Hénaine, R., & Lehot, J.-J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318192a36b · Cited by 214
Self-citationCannesson, M., Besnard, C., Durand, P. G., Bohé, J., & Jacques, D. (2005) · Critical Care · doi:10.1186/cc3799 · Cited by 186
Self-citationPulse oximetry plethysmographic waveform during changes in blood volume
Shamir, M., Eidelman, L. A., Floman, Y., Kaplan, L., & Pizov, R. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.2.178 · Cited by 184
THE EFFECT OF AGE ON THE ELASTICITY OF HUMAN ILIAC ARTERIES
Roach, M. R., & Burton, A. C. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-059 · Cited by 176
Non-invasive prediction of fluid responsiveness during major hepatic surgery † ‡
Solus-Biguenet, H., Fleyfel, M., Tavernier, B., Kipnis, E., Onimus, J., Robin, E., Lebuffe, G., Decoene, C., Pruvot, F. R., & Vallet, B. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael250 · Cited by 169
Rutlen, D. L., Wackers, F. J., & Zaret, B. L. (1981) · Circulation · doi:10.1161/01.cir.64.1.146 · Cited by 167
Zimmermann, M., Feibicke, T., Keyl, C., Prasser, C., Moritz, S., Graf, B. M., & Wiesenack, C. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e328335fbd1 · Cited by 167
PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
DORLAS, J. C., & NIJBOER, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160
Neto, E. P. D. S., Grousson, S., Duflo, F., Ducreux, C., Joly, H., Convert, J., Mottolèse, C., Dailler, F., & Cannesson, M. P. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer090 · Cited by 142
Self-citationPrediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
Byon, H., Lim, C.-W., Lee, J.-H., Park, Y.-H., Kim, H.-S., Kim, C. S., & Kim, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes467 · Cited by 139
Singer, M., Allen, M., Webb, A. R., & Bennett, E. (1991) · Critical Care Medicine · doi:10.1097/00003246-199109000-00008 · Cited by 139
Sandroni, C., Cavallaro, F., Marano, C., Falcone, C., Santis, P. D., & Antonelli, M. M. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2621-1 · Cited by 134
Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children
Durand, P., Chevret, L., Essouri, S., Haas, V., & Devictor, D. J. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1021-z · Cited by 128 · cited 1×
“(1) Characteristics of trial participants (age, weight, relevant clinical diagnosis, vasoactive therapy) (2) Characteristics of study (clinical setting, ventilation, fluid bolus type, volume, and duration) (3) Reference standard used (definition of response, method of assessment) (4) Variables tested (method of assess…”
MethodAge-associated changes in arterial elastic properties in children
Senzaki, H., Akagi, M., Hishi, T., et al. (2002) · European Journal of Pediatrics · doi:10.1007/s00431-002-1025-6 · Cited by 116
Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
Lee, J.-H., Kim, J., Yoon, S., Lim, Y., Jeon, Y., Bahk, J.-H., & Kim, C. S. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem179 · Cited by 110
Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery
Renner, J., BROCH, O. J., Dütschke, P., Scheewe, J., Höcker, J., Moseby, M., Jung, O., & Bein, B. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer371 · Cited by 107
Pleth variability index predicts fluid responsiveness in critically ill patients*
Loupec, T., Nanadoumgar, H., Frasca, D., Petitpas, F., Laksiri, L., Baudouin, D., Debaene, B., Dahyot‐Fizelier, C., & Mimoz, O. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181ffde1c · Cited by 104
Non‐invasive prediction of fluid responsiveness in infants using pleth variability index
Renner, J., BROCH, O. J., Gruenewald, M., et al. (2011) · Anaesthesia · doi:10.1111/j.1365-2044.2011.06715.x · Cited by 98
Clinical assessment of cardiac performance in infants and children following cardiac surgery
Egan, J. R., Festa, M. S., Cole, A. D., Nunn, G. R., Gillis, J., & Winlaw, D. S. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2569-5 · Cited by 95
Choi, D. Y., Kwak, H. J., Park, H. Y., Kim, Y. B., Choi, C. H., & Lee, J. Y. (2010) · Pediatric Cardiology · doi:10.1007/s00246-010-9776-8 · Cited by 93 · cited 1×
“(1) Characteristics of trial participants (age, weight, relevant clinical diagnosis, vasoactive therapy) (2) Characteristics of study (clinical setting, ventilation, fluid bolus type, volume, and duration) (3) Reference standard used (definition of response, method of assessment) (4) Variables tested (method of assess…”
MethodPleth Variability Index to Predict Fluid Responsiveness in Colorectal Surgery
Hood, J. A., & Wilson, R. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31822c10cd · Cited by 78
Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler
Slama, M., Masson, H., Teboul, J., Arnould, M.-L., Nait-Kaoudjt, R., Colas, B., Peltier, M., Tribouilloy, C., Sušić, D., Frohlich, E. D., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2190-z · Cited by 77
Lukito, V., Djer, M. M., Pudjiadi, A. H., & Munasir, Z. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3182388ab3 · Cited by 56 · cited 1×
“(1) Characteristics of trial participants (age, weight, relevant clinical diagnosis, vasoactive therapy) (2) Characteristics of study (clinical setting, ventilation, fluid bolus type, volume, and duration) (3) Reference standard used (definition of response, method of assessment) (4) Variables tested (method of assess…”
MethodRAUX, O., Spencer, A., Fesseau, R., Mercier, G., Rochette, A., Bringuier, S., Lakhal, K., Capdevila, X., & Dadure, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer336 · Cited by 51 · cited 1×
“(1) Characteristics of trial participants (age, weight, relevant clinical diagnosis, vasoactive therapy) (2) Characteristics of study (clinical setting, ventilation, fluid bolus type, volume, and duration) (3) Reference standard used (definition of response, method of assessment) (4) Variables tested (method of assess…”
MethodSpotnitz, W. D., Spotnitz, H. M., Truccone, N. J., Cottrell, T. S., Gersony, W. M., Malm, J. R., & Sonnenblick, E. H. (1979) · Circulation Research · doi:10.1161/01.res.44.5.679 · Cited by 25
Cited by
Weiss, S. L., Peters, M. J., Alhazzani, W., Agus, M. S. D., Flori, H. R., Inwald, D. P., Nadel, S., Schlapbach, L. J., Tasker, R. C., Argent, A. C., et al. (2020) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002198 · Cited by 1,228
Weiss, S. L., Peters, M. J., Alhazzani, W., Agus, M. S. D., Flori, H. R., Inwald, D. P., Nadel, S., Schlapbach, L. J., Tasker, R. C., Argent, A. C., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05878-6 · Cited by 606
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Levitov, A., Frankel, H. L., Blaivas, M., Kirkpatrick, A. W., Su, E., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001847 · Cited by 440
Egi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
Metadata
- Authors
- Gan, H., Cannesson, M., Chandler, J. R., & Ansermino, J. M.
- Venue
- Anesthesia & Analgesia
- Published
- 2013-12
- Volume
- 117
- Issue
- 6
- Pages
- 1380-1392
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2103076545
- Cited by
- 226
- References
- 48
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.