CoChat

DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES

Sillay, Karl A., Larson, Paul S., Starr, Philip A. · 2008 · Neurosurgery
Cited by 225

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Device-related infection is a common complication of deep brain stimulator (DBS) implantation. We reviewed the incidence and management of early hardware-related infections in a large series. METHODS: All patients undergoing DBS implantation surgery between 1998 and 2006 at a single institution were entered into a prospectively designed database. After database verification by cross-referencing manufacturer implantation records, a query was performed to include all new Medtronic (Minneapolis, MN) implantations performed with standard operating room technique. Hardware-related infections requiring further surgery were identified, and charts were reviewed to assess the success of lead-sparing partial hardware removal in this group. RESULTS: Four hundred twenty patients received 759 new DBS electrodes and 615 new internal pulse generators for the treatment of movement disorders or pain. Nineteen patients (4.5%) had an early (<6 mo) hardware-related infection requiring further surgery. There were no intracranial infections. Four patients presented with extensive cellulitis or wound dehiscence and were treated with total hardware removal. Fourteen patients presented with more localized infections and were treated by removal of the involved components only, followed by intravenously administered antibiotics. In nine of these patients, partial hardware removal successfully resolved the infection without requiring removal of the DBS electrodes. Wound washout alone was attempted in one patient and failed. CONCLUSION: In a large series of new DBS hardware implantations, the incidence of postoperative hardware-related infection requiring further surgery was 4.5%. When only one device component was involved, partial hardware removal was often successful.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000316002.03765.33

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 10

  1. Ido, 1996, Suction/irrigation for deep wound infection after spinal instrumentation: A case study., Eur Spine J, 5, 345, 10.1007/BF00304351 · doi:10.1007/bf00304351
  2. Lyons, 2001, Surgical and device-related events with deep brain stimulation (abstract)., Neurology, 56, A146
  3. Masterson, 1984, Bacteriologic evaluation of electric clippers for surgical hair removal., Am J Surg, 148, 301, 10.1016/0002-9610(84)90458-6 · doi:10.1016/0002-9610(84)90458-6
  4. Merello, 2001, Delayed intracerebral electrode infection after bilateral STN implantation for Parkinsons disease. Case report., Mov Disord, 16, 168, 10.1002/1531-8257(200101)16:1<168::AID-MDS1032>3.0.CO;2-N · doi:10.1002/1531-8257(200101)16:1<168::aid-mds1032>3.0.co;2-n
  5. Seal, 2004, A systems approach to preoperative surgical patient skin preparation., Am J Infect Control, 32, 57, 10.1016/j.ajic.2003.11.001 · doi:10.1016/j.ajic.2003.11.001
  6. Tulipan, 2006, Effect of an intraoperative double-gloving strategy on the incidence of cerebrospinal fluid shunt infection., J Neurosurg, 104, 5
  7. Vingerhoets, 2002, : Results and adverse events in 50 consecutive patients treated by STN-DBS., Mov Disord, 17, 666
  8. Constantoyannis, 2005, Reducing hardware-related complications of deep brain stimulation., Can J Neurol Sci, 32, 194, 10.1017/S0317167100003966 · DOI
  9. Temel, 2004, Management of hardware infections following deep brain stimulation., Acta Neurochir (Wien), 146, 355, 10.1007/s00701-004-0219-2 · DOI
  10. Voges, 2006, Deep-brain stimulation: Long-term analysis of complications caused by hardware and surgeryExperiences from a single centre., J Neurol Neurosurg Psychiatry, 77, 868, 10.1136/jnnp.2005.081232 · DOI · Paper page

Cited by

Metadata

Authors
Sillay, K. A., Larson, P. S., & Starr, P. A.
Venue
Neurosurgery
Published
2008-02
Volume
62
Issue
2
Pages
360-367
ISSN
0148-396X (ISSN-L)
OpenAlex
W1964469897
Cited by
225
References
28
FWCI
7.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.