Abstract
OBJECTIVE: Device-related infection is a common complication of deep brain stimulator (DBS) implantation. We reviewed the incidence and management of early hardware-related infections in a large series. METHODS: All patients undergoing DBS implantation surgery between 1998 and 2006 at a single institution were entered into a prospectively designed database. After database verification by cross-referencing manufacturer implantation records, a query was performed to include all new Medtronic (Minneapolis, MN) implantations performed with standard operating room technique. Hardware-related infections requiring further surgery were identified, and charts were reviewed to assess the success of lead-sparing partial hardware removal in this group. RESULTS: Four hundred twenty patients received 759 new DBS electrodes and 615 new internal pulse generators for the treatment of movement disorders or pain. Nineteen patients (4.5%) had an early (<6 mo) hardware-related infection requiring further surgery. There were no intracranial infections. Four patients presented with extensive cellulitis or wound dehiscence and were treated with total hardware removal. Fourteen patients presented with more localized infections and were treated by removal of the involved components only, followed by intravenously administered antibiotics. In nine of these patients, partial hardware removal successfully resolved the infection without requiring removal of the DBS electrodes. Wound washout alone was attempted in one patient and failed. CONCLUSION: In a large series of new DBS hardware implantations, the incidence of postoperative hardware-related infection requiring further surgery was 4.5%. When only one device component was involved, partial hardware removal was often successful.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257
A Comparison of Continuous Thalamic Stimulation and Thalamotomy for Suppression of Severe Tremor
Schuurman, P. R., Bosch, D. A., Bossuyt, P. M. M., Bonsel, G. J., van Someren, E. J. W., de Bie, R. M. A., Merkus, M. P., & Speelman, J. D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420703 · Cited by 1,044
Multicentre European study of thalamic stimulation in parkinsonian and essential tremor
Limousin, P., Speelman, J. D., Gielen, F., Janssens, M., & collaborators, S. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.66.3.289 · Cited by 491
High‐frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor
Koller, W., Pahwa, R., Busenbark, K., Hubble, J., Wilkinson, S., Lang, A., Tuite, P., Sime, E., Lazano, A., Hauser, R., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420304 · Cited by 478
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Self-citationLong-term Hardware-related Complications of Deep Brain Stimulation
Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M. (2002) · Neurosurgery · doi:10.1097/00006123-200206000-00017 · Cited by 405
Deep Brain Stimulation for Intractable Pain: A 15-Year Experience
Kumar, K., Toth, C., & Nath, R. K. (1997) · Neurosurgery · doi:10.1097/00006123-199704000-00015 · Cited by 387
Levy, R. M., Lamb, S., & Adams, J. E. (1987) · Neurosurgery · doi:10.1227/00006123-198712000-00017 · Cited by 319
Complications of Deep Brain Stimulation Surgery
Beric, A., Kelly, P. J., Rezai, A., Sterio, D., Mogilner, A., Zonenshayn, M., & Kopell, B. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000064600 · Cited by 316
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Voges, J. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.081232 · Cited by 273
Surgical and hardware complications of subthalamic stimulation: A series of 160 procedures
Lyons, K. E., Wilkinson, S. B., Overman, J., & Pahwa, R. (2004) · Neurology · doi:10.1212/01.wnl.0000134650.91974.1a · Cited by 271
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Hardware-related complications of deep brain stimulation: a ten year experience
Blomstedt, P., & Hariz, M. I. (2005) · Acta Neurochirurgica · doi:10.1007/s00701-005-0576-5 · Cited by 213
Hardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature
Hamani, C., & Lozano, A. M. (2006) · Stereotactic and Functional Neurosurgery · doi:10.1159/000096499 · Cited by 212
Thirty days complication rate following surgery performed for deep‐brain‐stimulation
Voges, J., Hilker, R., Bötzel, K., Kiening, K. L., Kloss, M., Kupsch, A., Schnitzler, A., Schneider, G., Steude, U., Deuschl, G., et al. (2007) · Movement Disorders · doi:10.1002/mds.21481 · Cited by 203
Treatment results: Parkinson's disease
Pollak, P., Fraix, V., Krack, P., Moro, E., Mendes, A., Chabardes, S., Koudsie, A., & Benabid, A.-L. (2002) · Movement Disorders · doi:10.1002/mds.10146 · Cited by 182
Deep brain stimulation for Parkinson's disease: Surgical issues
Rezai, A. R., Kopell, B. H., Gross, R. E., Vitek, J. L., Sharan, A. D., Limousin, P., & Benabid, A.-L. (2006) · Movement Disorders · doi:10.1002/mds.20956 · Cited by 176
Hardware-Related problems of deep brain stimulation
Joint, C., Nandi, D., Parkin, S., Gregory, R., & Aziz, T. (2002) · Movement Disorders · doi:10.1002/mds.10161 · Cited by 152
Antibiotic Prophylaxis for Cerebrospinal Fluid Shunts
Haines, S. J., & Walters, B. C. (1994) · Neurosurgery · doi:10.1097/00006123-199401000-00012 · Cited by 150
Antibiotic prophylaxis for cerebrospinal fluid shunts: a metanalysis.
Haines, S. J., & Walters, B. C. (1994) · PubMed · Cited by 141
Reducing Hardware-Related Complications of Deep Brain Stimulation
Constantoyannis, C., Berk, Ç., Honey, C. R., Mendez, I. M., & Brownstone, R. M. (2005) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100003966 · Cited by 139
Hardware-Related Complications after Placement of Thalamic Deep Brain Stimulator Systems
Kondziolka, D., Whiting, D., Germanwala, A., & Oh, M. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000070836 · Cited by 137
Deep Brain Stimulation for Dystonia
Coubes, P. A., Vayssière, N., Fertit, H. E., Hemm, S., Cif, L., Kienlen, J., Bonafé, A., & Frèrebeau, P. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000068962 · Cited by 118
Martin, A. J., Larson, P., Ostrem, J. L., Sootsman, W. K., Talke, P. O., Weber, O. M., Levesque, N., Myers, J., & Starr, P. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20675 · Cited by 114
Self-citationManagement of hardware infections following deep brain stimulation
van der Linden, C., van de Kar, T., Visser-Vandewalle, V. E. R. M., Temel, Y., Ackermans, L. P. C. M., Celik, H. H., Spincemaille, G. H. J. J., & Walenkamp, G. H. I. M. (2004) · Acta Neurochirurgica · doi:10.1007/s00701-004-0219-2 · Cited by 90
Hyperinsulinemia in Pre- and Post-Pubertal Children Born Small for Gestational Age
Potau, N., Gussinyé, M., Sanchez Ufarte, C., Riqué, S., Vicens-Calvet, E., & Carrascosa, A. (2001) · Hormone Research in Paediatrics · doi:10.1159/000048110 · Cited by 41
Subthalamic Nucleus Deep Brain Stimulation
Benabid, A., Koudsié, A., Benazzouz, A., Piallat, B., van Blerkom, N., Fraix, V., & Pollak, P. (2000) · KARGER eBooks · doi:10.1159/000062043 · Cited by 19
Research works printed but not linked: 10
- Ido, 1996, Suction/irrigation for deep wound infection after spinal instrumentation: A case study., Eur Spine J, 5, 345, 10.1007/BF00304351 · doi:10.1007/bf00304351
- Lyons, 2001, Surgical and device-related events with deep brain stimulation (abstract)., Neurology, 56, A146
- Masterson, 1984, Bacteriologic evaluation of electric clippers for surgical hair removal., Am J Surg, 148, 301, 10.1016/0002-9610(84)90458-6 · doi:10.1016/0002-9610(84)90458-6
- Merello, 2001, Delayed intracerebral electrode infection after bilateral STN implantation for Parkinsons disease. Case report., Mov Disord, 16, 168, 10.1002/1531-8257(200101)16:1<168::AID-MDS1032>3.0.CO;2-N · doi:10.1002/1531-8257(200101)16:1<168::aid-mds1032>3.0.co;2-n
- Seal, 2004, A systems approach to preoperative surgical patient skin preparation., Am J Infect Control, 32, 57, 10.1016/j.ajic.2003.11.001 · doi:10.1016/j.ajic.2003.11.001
- Tulipan, 2006, Effect of an intraoperative double-gloving strategy on the incidence of cerebrospinal fluid shunt infection., J Neurosurg, 104, 5
- Vingerhoets, 2002, : Results and adverse events in 50 consecutive patients treated by STN-DBS., Mov Disord, 17, 666
- Constantoyannis, 2005, Reducing hardware-related complications of deep brain stimulation., Can J Neurol Sci, 32, 194, 10.1017/S0317167100003966 · DOI
- Temel, 2004, Management of hardware infections following deep brain stimulation., Acta Neurochir (Wien), 146, 355, 10.1007/s00701-004-0219-2 · DOI
- Voges, 2006, Deep-brain stimulation: Long-term analysis of complications caused by hardware and surgeryExperiences from a single centre., J Neurol Neurosurg Psychiatry, 77, 868, 10.1136/jnnp.2005.081232 · DOI · Paper page
Cited by
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Deep-Brain Stimulation for Parkinson's Disease
Okun, M. S. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1208070 · Cited by 541
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Review: Deep brain stimulation in Parkinson’s disease
Groiss, S. J., Wojtecki, L., Südmeyer, M., & Schnitzler, A. (2009) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756285609339382 · Cited by 280
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Metadata
- Authors
- Sillay, K. A., Larson, P. S., & Starr, P. A.
- Venue
- Neurosurgery
- Published
- 2008-02
- Volume
- 62
- Issue
- 2
- Pages
- 360-367
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1964469897
- Cited by
- 225
- References
- 28
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.