Comparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the validity of five physical activity monitors available for research: the CSA, the TriTrac-R3D, the RT3, the SenseWear Armband, and the BioTrainer-Pro. METHODS: A total of 10 healthy men and 11 healthy women performed 10 min of treadmill walking at 54, 80, and 107 mxmin and treadmill running at 134, 161, 188, and 214 mxmin. The CSA, TriTrac-R3D, RT3, and BioTrainer-Pro accelerometers were placed side by side bilaterally at the waist in the axillary position, and the SenseWear Armband monitors were placed bilaterally on the posterior portion of each arm in the mid-humeral position. Simultaneous measurements of body motion and indirect calorimetry were continuously recorded during all exercise. Data were analyzed with repeated measures ANOVA and pairwise Bonferroni-adjusted estimated marginal means. RESULTS: : There was no significant difference in the mean energy expenditure (EE) recorded bilaterally by any of the monitors (P < 0.05) at any treadmill speed. The SenseWear Armband, the TriTrac-R3D, and the RT3 had significant increases in mean EE across all walking and running speeds (P < 0.05). Below 161 mxmin, the mean EE recorded by the BioTrainer-Pro and the CSA increased significantly (P < 0.001); however, there was no significant difference (P > 0.10) in mean EE recorded by either monitor for speeds above 161 mxmin. In general, all monitors overestimated EE at most treadmill speeds when compared with indirect calorimetry (P < 0.001), except for the CSA which underestimated EE at the lowest and highest speeds. CONCLUSION: The CSA was the best estimate of total EE at walking and jogging speeds, the TriTrac-R3D was the best estimate of total EE at running speeds, and the SenseWear Armband was the best estimate of total EE at most speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Crespo, C. J. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440010113015 · Cited by 504
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Assessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 424
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“(Additional file 1: figure S3h) [374].”
A novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E. (2007) · Obesity · doi:10.1038/oby.2007.624 · Cited by 244
“9) has been shown to have improved utility in recent studies (12,14), but additional enhancements have been made in the software (Interview Research Software, version 4.”
BackgroundComparative Validity of Physical Activity Measures in Older Adults
COLBERT, L. H., MATTHEWS, C. E., HAVIGHURST, T. C., KIM, K., & SCHOELLER, D. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fc7162 · Cited by 224
“Newer multisensor methods like that used in the SW armband may improve on standard accelerometers for the estimation of PAEE (17).”
MethodKelly, L. A., McMillan, D. G., Anderson, A., Fippinger, M., Fillerup, G., & Rider, J. (2013) · BMC Medical Physics · doi:10.1186/1756-6649-13-5 · Cited by 220
Validity of physical activity monitors in adults participating in free-living activities
Berntsen, S., Hageberg, R., Aandstad, A., Mowinckel, P., Anderssen, S. A., Carlsen, K.-H., & Andersen, L. B. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048868 · Cited by 191
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-099643 · Cited by 188
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Hale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118
Doherty, S. T., Lemieux, C. J., & Canally, C. (2014) · Social Science & Medicine · doi:10.1016/j.socscimed.2014.01.048 · Cited by 110
Nutritional, lifestyle, and weight control practices of professional jockeys
Dolan, E., O'Connor, H., McGoldrick, A., O'Loughlin, G., Lyons, D., & Warrington, G. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2011.560173 · Cited by 107
Methodology for Using Long-Term Accelerometry Monitoring to Describe Daily Activity Patterns in COPD
Hecht, A., Ma, S., Porszasz, J., Casaburi, R., & Netw, F. T. C. C. R. (2009) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550902755044 · Cited by 91
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Tierney, M., Fraser, A., Purtill, H., & Kennedy, N. (2013) · Arthritis Care & Research · doi:10.1002/acr.21914 · Cited by 56
Vanroy, C., Vissers, D., Cras, P., Beyne, S., Feys, H., Vanlandewijck, Y., & Truijen, S. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2013.859307 · Cited by 46
Metabolic Costs of Standing and Walking in Healthy Military-Age Adults: A Meta-regression
LOONEY, D. P., POTTER, A. W., PRYOR, J. L., BREMNER, P. E., CHALMERS, C. R., MCCLUNG, H. L., WELLES, A. P., & SANTEE, W. R. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001779 · Cited by 37
Metadata
- Authors
- KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-07
- Volume
- 36
- Issue
- 7
- Pages
- 1244-1251
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1982692230
- Cited by
- 238
- References
- 3
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.