Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: Previously, the National Health and Examination Survey measured physical activity with an accelerometer worn on the hip for 7 d but recently changed the location of the monitor to the wrist. This study compared estimates of physical activity intensity and type with an accelerometer on the hip versus the wrist. METHODS: Healthy adults (n = 37) wore triaxial accelerometers (Wockets) on the hip and dominant wrist along with a portable metabolic unit to measure energy expenditure during 20 activities. Motion summary counts were created, and receiver operating characteristic (ROC) curves were then used to determine sedentary and activity intensity thresholds. Ambulatory activities were separated from other activities using the coefficient of variation of the counts. Mixed-model predictions were used to estimate activity intensity. RESULTS: The ROC for determining sedentary behavior had greater sensitivity and specificity (71% and 96%) at the hip than at the wrist (53% and 76%), as did the ROC for moderate- to vigorous-intensity physical activity on the hip (70% and 83%) versus the wrist (30% and 69%). The ROC for the coefficient of variation associated with ambulation had a larger AUC at the hip compared to the wrist (0.83 and 0.74). The prediction model for activity energy expenditure resulted in an average difference of 0.55 ± 0.55 METs on the hip and 0.82 ± 0.93 METs on the wrist. CONCLUSIONS: Methods frequently used for estimating activity energy expenditure and identifying activity intensity thresholds from an accelerometer on the hip generally do better than similar data from an accelerometer on the wrist. Accurately identifying sedentary behavior from a lack of wrist motion presents significant challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“The National Health and Nutrition Examination Survey (NHANES) previously relied on an accelerometer worn on the hip to measure physical activity and sedentary behavior (43).”
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Self-citationToo Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202 · cited 1×
“(31) that includes both sitting and low levels of energy expenditure (<1.”
Sitting time and mortality from all causes, cardiovascular disease, and cancer
KATZMARZYK, P. T., CHURCH, T. S., CRAIG, C. L., & BOUCHARD, C. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181930355 · Cited by 1,611
Healy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-2046 · Cited by 1,465
Sedentary time and cardio-metabolic biomarkers in US adults: NHANES 2003–06
Healy, G. N., Matthews, C. E., Dunstan, D. W., Winkler, E. A. H., & Owen, N. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq451 · Cited by 1,368 · cited 1×
“Although epidemiological studies have obtained positive results using MVPA thresholds to classify participants into categories of physical activity and relating it to health outcomes (20), this same approach may perform less well when data are collected from the wrist.”
Objectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 2×
“In an evaluation of the GENEA worn on both wrists and at the hip in 60 middle-aged men and women who performed 10–12 semi-structured physical activities the accelerometers all performed exceptionally well in assigning activities into intensity categories (12).”
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Young, D. R., Hivert, M.-F., Alhassan, S., Camhi, S. M., Ferguson, J. F., Katzmarzyk, P. T., Lewis, C. E., Owen, N., Perry, C. K., Siddique, J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000440 · Cited by 791
Accelerometry and physical activity questionnaires - a systematic review
Skender, S., Ose, J., Chang-Claude, J., Paskow, M., Brühmann, B., Siegel, E. M., Steindorf, K., & Ulrich, C. M. (2016) · BMC Public Health · doi:10.1186/s12889-016-3172-0 · Cited by 449
Activity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383
Self-citationThe 24-Hour Activity Cycle: A New Paradigm for Physical Activity
ROSENBERGER, M. E., FULTON, J. E., BUMAN, M. P., TROIANO, R. P., GRANDNER, M. A., BUCHNER, D. M., & HASKELL, W. L. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001811 · Cited by 372
Self-citationEllis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Barnett, T. A., Kelly, A. S., Young, D. R., Perry, C. K., Pratt, C. A., Edwards, N. M., Rao, G., Vos, M. B., & On behalf of the American Heart Association Obesity Committee of the Council on Lifestyle and Cardiometabolic Health; Council on Cardiovascular Disease in the Young; and Stroke Council (2018) · Circulation · doi:10.1161/cir.0000000000000591 · Cited by 249
Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification
ELLIS, K., KERR, J., GODBOLE, S., STAUDENMAYER, J., & LANCKRIET, G. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000840 · Cited by 186
Vigorous physical activity, incident heart disease, and cancer: how little is enough?
Ahmadi, M. N., Clare, P. J., Katzmarzyk, P. T., del Pozo Cruz, B., Lee, I. M., & Stamatakis, E. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac572 · Cited by 175
Identifying Children’s Nocturnal Sleep Using 24-h Waist Accelerometry
BARREIRA, T. V., SCHUNA, J. M., MIRE, E. F., KATZMARZYK, P. T., CHAPUT, J.-P., LEDUC, G., & TUDOR-LOCKE, C. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000486 · Cited by 163
Chastin, S., McGregor, D., Palarea-Albaladejo, J., Diaz, K. M., Hagströmer, M., Hallal, P. C., van Hees, V. T., Hooker, S., Howard, V. J., Lee, I.-M., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102345 · Cited by 162
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
“Studies investigating research-based accelerometers showed that different placements of the monitors caused varied estimations of raw accelerometer output (19), activity EE (27),”
BackgroundHekler, E. B., Buman, M. P., Grieco, L., Rosenberger, M., Winter, S. J., Haskell, W., & King, A. C. (2015) · JMIR mhealth and uhealth · doi:10.2196/mhealth.3505 · Cited by 137
Kleckner, I. R., Jones, R. M., Wilder-Smith, O., Wormwood, J. B., Akcakaya, M., Quigley, K. S., Lord, C., & Goodwin, M. S. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2758643 · Cited by 121
“sedentary or only moderately active during recording periods, although such designations are imperfect using only wrist-worn accelerometers [32].”
Jauho, A.-M., Pyky, R., Ahola, R., Kangas, M., Virtanen, P., Korpelainen, R., & Jämsä, T. (2015) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2015.07.005 · Cited by 84
“There are challenges when using a wristworn monitor in the measurement of daily PA behavior based on EE (Rosenberger et al., 2013; Hildebrand et al., 2014).”
BackgroundDegroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“Studies comparing the validity of research-grade accelerometers at different body locations consistently show that the hip position is more accurate than the wrist [65].”
BackgroundValidating Accelerometry as a Measure of Physical Activity and Energy Expenditure in Chronic Stroke
Serra, M. C., Balraj, E., DiSanzo, B. L., Ivey, F. M., Hafer-Macko, C. E., Treuth, M. S., & Ryan, A. S. (2017) · Topics in Stroke Rehabilitation · doi:10.1080/10749357.2016.1183866 · Cited by 46
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Mielke, G. I., de Almeida Mendes, M., Ekelund, U., Rowlands, A. V., Reichert, F. F., & Crochemore‐Silva, I. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14416 · Cited by 26
“Findings from our study were similar to those observed in previous studies 9,23,24 that showed differences between AG waist and AG wrist tent to be higher in activities with higher average acceleration, especially for circuit and running activities.”
ResultRuiz-Zafra, A., Orantes-González, E., Noguera, M., Benghazi, K., & Heredia-Jimenez, J. (2015) · Sensors · doi:10.3390/s150818270 · Cited by 13
Sleep, Dietary Patterns, and Energy Availability Status in Adolescent Female Artistic Gymnasts
K. Eberhardt, H., J. Ormsbee, M., & G. Saracino, P. (2026) · International Journal of Exercise Science · doi:10.70252/ijes2026218
Metadata
- Authors
- ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2013-05
- Volume
- 45
- Issue
- 5
- Pages
- 964-975
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2035855116
- Cited by
- 237
- References
- 14
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.