CoChat

Motivating Process Compliance Through Individual Electronic Monitoring: An Empirical Examination of Hand Hygiene in Healthcare

Open access
Staats, Bradley R., Dai, Hengchen, Hofmann, David, Milkman, Katherine L. · 2017 · Management Science
Cited by 183

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

The design and use of standard processes are foundational recommendations in many operations practices. Yet, given the demonstrated performance benefits of standardized processes, it is surprising that they are often not followed consistently. One way to ensure greater compliance is by electronically monitoring the activities of individuals, although such aggressive monitoring poses the risk of inducing backlash. In the setting of hand hygiene in healthcare, a context where compliance with standard processes is frequently less than 50% and where this lack of compliance can result in negative consequences, we investigated the effectiveness of electronic monitoring. We did so using a unique, radio frequency identification (RFID)-based system deployed in 71 hospital units. We found that electronically monitoring individual compliance resulted in a large, positive increase in compliance. We also found that there was substantial variability in the effect across units and that units with higher levels of preactivation compliance experienced increased benefits from monitoring relative to units with lower levels of prepreactivation compliance. By observing compliance rates over three and a half years, we investigated the persistent effects of individual monitoring and found that compliance rates initially increased before they gradually declined. Additionally, in multiple units, individual monitoring was discontinued, allowing for an investigation of the impact of removing the intervention on compliance. Surprisingly, we found that, after removal, compliance rates declined to below prepreactivation levels. Our findings suggest that, although individual electronic monitoring can dramatically improve process compliance, it requires sustained managerial commitment. This paper was accepted by Serguei Netessine, operations management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1287/mnsc.2015.2400

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 183

Metadata

Authors
Staats, B. R., Dai, H., Hofmann, D., & Milkman, K. L.
Venue
Management Science
Published
2017-05
Volume
63
Issue
5
Pages
1563-1585
ISSN
  • 0025-1909 (ISSN-L)
  • 1526-5501
OpenAlex
W2345685485
Cited by
183
References
59
FWCI
15.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.