Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We have studied the characteristics of bone ingrowth of a new porous tantalum biomaterial in a simple transcortical canine model using cylindrical implants 5 × 10 mm in size. The material was 75% to 80% porous by volume and had a repeating arrangement of slender interconnecting struts which formed a regular array of dodecahedron-shaped pores. We performed histological studies on two types of material, one with a smaller pore size averaging 430 μm at 4, 16 and 52 weeks and the other with a larger pore size averaging 650 μm at 2, 3, 4, 16 and 52 weeks. Mechanical push-out tests at 4 and 16 weeks were used to assess the shear strength of the bone-implant interface on implants of the smaller pore size. The extent of filling of the pores of the tantalum material with new bone increased from 13% at two weeks to between 42% and 53% at four weeks. By 16 and 52 weeks the average extent of bone ingrowth ranged from 63% to 80%. The tissue response to the small and large pore sizes was similar, with regions of contact between bone and implant increasing with time and with evidence of Haversian remodelling within the pores at later periods. Mechanical tests at four weeks indicated a minimum shear fixation strength of 18.5 MPa, substantially higher than has been obtained with other porous materials with less volumetric porosity. This porous tantalum biomaterial has desirable characteristics for bone ingrowth; further studies are warranted to ascertain its potential for clinical reconstructive orthopaedics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Self-citationKieswetter, K., Schwartz, Z., Hummert, T. W., Cochran, D. L., Simpson, J., Dean, D. D., & Boyan, B. D. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<55::aid-jbm7>3.0.co;2-o · Cited by 565
The effects of implant surface topography on the behavior of cells.
Brunette, D. M. (1988) · PubMed · Cited by 359
Tissue response to porous tantalum acetabular cups
Bobyn, J., Toh, K.-K., Hacking, S. A., Tänzer, M., & Krygier, J. J. (1999) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(99)90062-1 · Cited by 281
Self-citationCurrent Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
The rate of bone ingrowth into porous metal
Camron, H. U., Pilliar, R. M., & Macnab, I. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100210 · Cited by 208
Porous surface layered prosthetic devices.
Pilliar, R. M., Cameron, H. U., & Macnab, I. (1975) · PubMed · Cited by 152
The Osseous Response to Corundum Blasted Implant Surfaces in a Canine Hip Model
Hacking, S. A., Bobyn, J., Tänzer, M., & Krygier, J. J. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199907000-00031 · Cited by 58
Self-citationJohnson, P. F., Bernstein, J. J., Hunter, G. D., Dawson, W. W., & Hench, L. L. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110502 · Cited by 49
Cited by
Development of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Oh, S. H., Park, I. K., Kim, J. M., & Lee, J. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.024 · Cited by 713
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
Murr, L. E., Gaytan, S. M., Medina, F., Lopez, H., Martinez, E., Machado, B. I., Hernandez, D. H., Martinez, L., Lopez, M. I., Wicker, R. B., et al. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2010.0010 · Cited by 636
Arabnejad, S., Burnett Johnston, R., Pura, J. A., Singh, B., Tanzer, M., & Pasini, D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.10.048 · Cited by 578
Self-citationMetallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Balla, V. K., Bodhak, S., Bose, S., & Bandyopadhyay, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.01.046 · Cited by 504
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering
Brydone, A. S., Meek, D., & Maclaine, S. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim770 · Cited by 456
Song, B., Zhao, X., Li, S., Han, C., Wei, Q., Wen, S., Liu, J., & Shi, Y. (2015) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-015-0341-2 · Cited by 427
Additively manufactured porous tantalum implants
Wauthle, R., van der Stok, J., Amin Yavari, S., Van Humbeeck, J., Kruth, J.-P., Zadpoor, A. A., Weinans, H., Mulier, M., & Schrooten, J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.12.003 · Cited by 417
Mullen, L., Stamp, R. C., Brooks, W. K., Jones, E., & Sutcliffe, C. J. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31219 · Cited by 410
Zhao, Y., Wong, H. M., Wang, W., Li, P., Xu, Z., Chong, E. Y. W., Yan, C. H., Yeung, K. W. K., & Chu, P. K. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.071 · Cited by 387
(2018) · PubMed Central · Cited by 365
Direct laser processing of a tantalum coating on titanium for bone replacement structures
Balla, V. K., Banerjee, S., Bose, S., & Bandyopadhyay, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.021 · Cited by 333
Wang, L., He, S., Wu, X., Liang, S., Mu, Z., Wei, J., Deng, F., Deng, Y., & Wei, S. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.085 · Cited by 303
Three-dimensional printing of metals for biomedical applications
Ni, J., Ling, H., Zhang, S., Wang, Z., Peng, Z., Benyshek, C., Zan, R., Miri, A. K., Li, Z., Zhang, X., et al. (2019) · Materials Today Bio · doi:10.1016/j.mtbio.2019.100024 · Cited by 279
The elements of life and medicines
Chellan, P., & Sadler, P. J. (2015) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2014.0182 · Cited by 274
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Metals for bone implants. Part 1. Powder metallurgy and implant rendering
Andani, M. T., Shayesteh Moghaddam, N., Haberland, C., Dean, D., Miller, M. J., & Elahinia, M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.025 · Cited by 258
Processing and mechanical properties of autogenous titanium implant materials
Wen, C. E., Yamada, Y., Shimojima, K., Chino, Y., Asahina, T., & Mabuchi, M. (2002) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1014344819558 · Cited by 254
The development and future of dental implants
ALGHAMDI, H. S., & JANSEN, J. A. (2020) · Dental Materials Journal · doi:10.4012/dmj.2019-140 · Cited by 253
Zhang, S., Wei, Q., Cheng, L., Li, S., & Shi, Y. (2014) · Materials & Design · doi:10.1016/j.matdes.2014.05.021 · Cited by 219
Lin, C., Wirtz, T., LaMarca, F., & Hollister, S. J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31231 · Cited by 198
“Porous tantalum is fabricated via a chemical vapor infiltration (CVI) process that forms a reticulated vitreous carbon (RVC) skeleton, which is then encased by the precipitation of tantalum metal.(13,14) The material is comprised of 75–85% void space and is characterized by interconnected unit cells that possess dodec…”
MethodPlasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
Walsh, W. R., Bertollo, N., Christou, C., Schaffner, D., & Mobbs, R. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.018 · Cited by 197
Carluccio, D., Xu, C., Venezuela, J., Cao, Y., Kent, D., Bermingham, M., Demir, A. G., Previtali, B., Ye, Q., & Dargusch, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.018 · Cited by 195
Arabnejad Khanoki, S., & Pasini, D. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006115 · Cited by 192
Gradient nano-engineered in situ forming composite hydrogel for osteochondral regeneration
Radhakrishnan, J., Manigandan, A., Chinnaswamy, P., Subramanian, A., & Sethuraman, S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.056 · Cited by 181
Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013) · Artificial Organs · doi:10.1111/aor.12153 · Cited by 181
VEILLETTE, C. J. H., MEHDIAN, H., SCHEMITSCH, E. H., & MCKEE, M. D. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200611001-00008 · Cited by 140
Shah, F. A., Ruscsák, K., & Palmquist, A. (2019) · Bone Research · doi:10.1038/s41413-019-0053-z · Cited by 115
Metadata
- Authors
- Bobyn, J. D., Stackpool, G. J., Hacking, S. A., Tanzer, M., & Krygier, J. J.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1999-09
- Volume
- 81-B
- Issue
- 5
- Pages
- 907-914
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2081554679
- Cited by
- 1,037
- References
- 9
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.