The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Correct positioning and alignment of components during primary total knee replacement (TKR) is widely accepted to be an important predictor of patient satisfaction and implant durability. This retrospective study reports the effect of the post-operative mechanical axis of the lower limb in the coronal plane on implant survival following primary TKR. A total of 501 TKRs in 396 patients were divided into an aligned group with a neutral mechanical axis (± 3°) and a malaligned group where the mechanical axis deviated from neutral by > 3°. At 15 years’ follow-up, 33 of 458 (7.2%) TKRs were revised for aseptic loosening. Kaplan-Meier survival analysis showed a weak tendency towards improved survival with restoration of a neutral mechanical axis, but this did not reach statistical significance (p = 0.47). We found that the relationship between survival of a primary TKR and mechanical axis alignment is weaker than that described in a number of previous reports.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Why Are Total Knee Arthroplasties Failing Today?
Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200211000-00003 · Cited by 1,354
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Baker, P. N., van der Meulen, J. H., Lewsey, J., & Gregg, P. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19091 · Cited by 975
Self-citationPredicting dissatisfaction following total knee replacement: A PROSPECTIVE STUDY OF 1217 PATIENTS
Scott, C. E. H., Howie, C. R., MacDonald, D., & Biant, L. C. (2010) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.92b9.24394 · Cited by 874
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
Coronal Alignment in Total Knee Arthroplasty
Fang, D. M., Ritter, M. A., & DAVIS, K. E. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.04.034 · Cited by 735
Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b5.14927 · Cited by 667
FACTORS AFFECTING THE DURABILITY OF PRIMARY TOTAL KNEE PROSTHESES
RAND, J. A., TROUSDALE, R. T., ILSTRUP, D. M., & HARMSEN, W. S. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200302000-00012 · Cited by 471
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Cited by
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Kim, Y.-H., Park, J.-W., Kim, J.-S., & Park, S.-D. (2014) · International Orthopaedics · doi:10.1007/s00264-013-2097-9 · Cited by 367
Howell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2621-x · Cited by 366
Vanlommel, L., Vanlommel, J., Claes, S., & Bellemans, J. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2481-4 · Cited by 322
Almaawi, A. M., Hutt, J. R. B., Masse, V., Lavigne, M., & Vendittoli, P.-A. (2017) · The Journal of Arthroplasty · doi:10.1016/j.arth.2017.02.028 · Cited by 302
Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
Howell, S. M., Shelton, T. J., & Hull, M. L. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.07.020 · Cited by 302
de Steiger, R. N., Liu, Y.-L., & Graves, S. E. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.01496 · Cited by 267
Calliess, T., Bauer, K., Stukenborg-Colsman, C., Windhagen, H., Budde, S., & Ettinger, M. (2017) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4136-8 · Cited by 245
Waterson, H. B., Clement, N. D., Eyres, K. S., Mandalia, V. I., & Toms, A. D. (2016) · The Bone & Joint Journal · doi:10.1302/0301-620x.98b10.36862 · Cited by 206
Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty
Lee, Y. S., Howell, S. M., Won, Y.-Y., Lee, O.-S., Lee, S. H., Vahedi, H., & Teo, S. H. (2017) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-017-4558-y · Cited by 191
“However, it has also been reported that failure rates do not correlate with the alignment outliers following TKA, and a high percentage of patients are unsatisfied after MA TKA [5, 6, 14, 20, 21].”
BackgroundKinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument
Kim, K.-K., Howell, S. M., & Won, Y.-Y. (2020) · Yonsei Medical Journal · doi:10.3349/ymj.2020.61.3.201 · Cited by 23
“On the contrary, there is a weak relationship between the alignment (in-range, varus and valgus outlier groups) of the limb and the survival of implant and clinical outcomes of primary TKA.(8-15) For these reasons, a different technique is needed to align a TKA performed with the goal of improving patient’s function a…”
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Metadata
- Authors
- Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2011-09
- Volume
- 93-B
- Issue
- 9
- Pages
- 1217-1222
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2162281953
- Cited by
- 302
- References
- 22
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.