Electrochemical Biosensors: Recommended Definitions and Classification
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Two Divisions of the International Union of Pure and Applied Chemistry (IUPAC), namely Physical Chemistry (Commission I.7 on Biophysical Chemistry formerly Steering Committee on Biophysical Chemistry) and Analytical Chemistry (Commission V.5 on Electroanalytical Chemistry) have prepared recommendations on the definition, classification and nomenclature related to electrochemical biosensors; these recommendations could, in the future, be extended to other types of biosensors. An electrochemical biosensor is a self-contained integrated device, which is capable of providing specific quantitative or semi-quantitative analytical information using a biological recognition element (biochemical receptor) which is retained in direct spatial contact with an electrochemical transduction element. Because of their ability to be repeatedly calibrated, we recommend that a biosensor should be clearly distinguished from a bioanalytical system, which requires additional processing steps, such as reagent addition. A device which is both disposable after one measurement, i.e., single use, and unable to monitor the analyte concentration continuously or after rapid and reproducible regeneration should be designated a single use biosensor. Biosensors may be classified according to the biological specificity-conferring mechanism or, alternatively, to the mode of physico-chemical signal transduction. The biological recognition element may be based on a chemical reaction catalysed by, or on an equilibrium reaction with macromolecules that have been isolated, engineered or present in their original biological environment. In the latter cases, equilibrium is generally reached and there is no further, if any, net consumption of analyte(s) by the immobilized biocomplexing agent incorporated into the sensor. Biosensors may be further classified according to the analytes or reactions that they monitor: direct monitoring of analyte concentration or of reactions producing or consuming such analytes; alternatively, an indirect monitoring of inhibitor or activator of the biological recognition element (biochemical receptor) may be achieved. A rapid proliferation of biosensors and their diversity has led to a lack of rigour in defining their performance criteria. Although each biosensor can only truly be evaluated for a particular application, it is still useful to examine how standard protocols for performance criteria may be defined in accordance with standard IUPAC protocols or definitions. These criteria are recommended for authors, referees and educators and include calibration characteristics (sensitivity, operational and linear concentration range, detection and quantitative determination limits), selectivity, steady-state and transient response times, sample throughput, reproducibility, stability and lifetime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Habermehl, G. (1983) · Toxicon · doi:10.1016/0041-0101(83)90286-6 · Cited by 3,092
Compendium of chemical terminology
Gold, V. (1987) · Cited by 2,525
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
Self-citationIUPAC Compendium of Analytical Nomenclature
Horwitz, W. (1979) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/62.4.967c · Cited by 117
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Biosensors and their applications – A review
Mehrotra, P. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.12.002 · Cited by 1,526
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Microbial siderophores and their potential applications: a review
Saha, M., Sarkar, S., Sarkar, B., Sharma, B. K., Bhattacharjee, S., & Tribedi, P. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-4294-0 · Cited by 819
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Hydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Advances in biosensors: Principle, architecture and applications
Perumal, V., & Hashim, U. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.jab.2013.02.001 · Cited by 606
Aptamers: molecular tools for analytical applications
Mairal, T., Cengiz Özalp, V., Lozano Sánchez, P., Mir, M., Katakis, I., & O’Sullivan, C. K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1346-4 · Cited by 587
Recent Advances in Electrochemical Biosensors: Applications, Challenges, and Future Scope
Singh, A., Sharma, A., Ahmed, A., Sundramoorthy, A. K., Furukawa, H., Arya, S., & Khosla, A. (2021) · Biosensors · doi:10.3390/bios11090336 · Cited by 579
Recent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
Spherical whispering‐gallery‐mode microresonators
Chiasera, A., Dumeige, Y., Féron, P., Ferrari, M., Jestin, Y., Nunzi Conti, G., Pelli, S., Soria, S., & Righini, G. C. (2010) · Laser & Photonics Reviews · doi:10.1002/lpor.200910016 · Cited by 514
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Recent Developments of Carbon Dots in Biosensing: A Review
Ji, C., Zhou, Y., Leblanc, R. M., & Peng, Z. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01556 · Cited by 461
Electrochemically synthesized polymers in molecular imprinting for chemical sensing
Sharma, P. S., Pietrzyk-Le, A., D’Souza, F., & Kutner, W. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5696-6 · Cited by 459
Nanomaterials-based biosensor and their applications: A review
Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e19929 · Cited by 441
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Electrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Enzyme Mimics: Advances and Applications
Kuah, E., Toh, S., Yee, J., Ma, Q., & Gao, Z. (2016) · Chemistry – A European Journal · doi:10.1002/chem.201504394 · Cited by 351
Impedance-Based Detection of Bacteria
Furst, A. L., & Francis, M. B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00381 · Cited by 321
Malhotra, B. D., & Ali, M. A. (2018) · Nanomaterials for Biosensors · doi:10.1016/b978-0-323-44923-6.00001-7 · Cited by 319
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
(Bio)sensors for measurement of analytes implicated in food safety: a review
Patel, P. D. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00136-4 · Cited by 314
Fritea, L., Banica, F., Costea, T., Moldovan, L., Dobjanschi, L., Muresan, M., & Cavalu, S. (2021) · Materials · doi:10.3390/ma14216319 · Cited by 311
Mohammed, M.-I., & Desmulliez, M. P. Y. (2011) · Lab Chip · doi:10.1039/c0lc00204f · Cited by 304
Photoelectrochemical enzymatic biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.009 · Cited by 301
Terminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
Applications of Graphene Quantum Dots in Biomedical Sensors
Mansuriya, B., & Altintas, Z. (2020) · Sensors · doi:10.3390/s20041072 · Cited by 276
Fazio, E., Spadaro, S., Corsaro, C., Neri, G., Leonardi, S. G., Neri, F., Lavanya, N., Sekar, C., Donato, N., & Neri, G. (2021) · Sensors · doi:10.3390/s21072494 · Cited by 274
Biosensors - classification, characterization and new trends
Monošík, R., Streďanský, M., & Šturdík, E. (2012) · Acta Chimica Slovaca · doi:10.2478/v10188-012-0017-z · Cited by 269
Functionalized TiO2 Based Nanomaterials for Biomedical Applications
Wu, S., Weng, Z., Liu, X., Yeung, K. W. K., & Chu, P. K. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400706 · Cited by 269
Khodadadi, A., Faghih-Mirzaei, E., Karimi-Maleh, H., Abbaspourrad, A., Agarwal, S., & Gupta, V. K. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.12.164 · Cited by 269
Research and development in biosensors
Scheller, F. W., Wollenberger, U., Warsinke, A., & Lisdat, F. (2001) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00169-5 · Cited by 267
Recent advances in cholesterol biosensor
Arya, S. K., Datta, M., & Malhotra, B. D. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.018 · Cited by 262
Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications
Paimard, G., Ghasali, E., & Baeza, M. (2023) · Chemosensors · doi:10.3390/chemosensors11020113 · Cited by 255
Protein Detection with Aptamer Biosensors
Strehlitz, B., Nikolaus, N., & Stoltenburg, R. (2008) · Sensors · doi:10.3390/s8074296 · Cited by 237
Terminology of electrochemical methods of analysis (IUPAC Recommendations 2019)
Pingarrón, J. M., Labuda, J., Barek, J., Brett, C. M. A., Camões, M. F., Fojta, M., & Hibbert, D. B. (2020) · Pure and Applied Chemistry · doi:10.1515/pac-2018-0109 · Cited by 227
Current and Future Technologies for the Detection of Antibiotic-Resistant Bacteria
Yamin, D., Uskoković, V., Wakil, A., Goni, M., Shamsuddin, S., Mustafa, F., Alfouzan, W., Alissa, M., Alshengeti, A., Almaghrabi, R., et al. (2023) · Diagnostics · doi:10.3390/diagnostics13203246 · Cited by 214
Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook
Kurzweil, P. (2009) · Sensors · doi:10.3390/s90604955 · Cited by 212
Conducting Polymers, Hydrogels and Their Composites: Preparation, Properties and Bioapplications
Tomczykowa, M., & Plonska-Brzezinska, M. (2019) · Polymers · doi:10.3390/polym11020350 · Cited by 205
Electrochemical Biosensors for Medical and Food Applications
Ahmed, M. U., Hossain, M. M., & Tamiya, E. (2008) · Electroanalysis · doi:10.1002/elan.200704121 · Cited by 195
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Self-citationPolyaniline-based glucose biosensor: A review
Lai, J., Yi, Y., Zhu, P., Shen, J., Wu, K., Zhang, L., & Liu, J. (2016) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2016.10.033 · Cited by 168
Electrolytic Gated Organic Field-Effect Transistors for Application in Biosensors—A Review
Wang, D., Noël, V., & Piro, B. (2016) · Electronics · doi:10.3390/electronics5010009 · Cited by 165
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Metadata
- Authors
- Thevenot, D. R., Tóth, K., Durst, R. A., & Wilson, G. S.
- Venue
- Pure and Applied Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 1999-01-01
- Volume
- 71
- Issue
- 12
- Pages
- 2333-2348
- ISSN
- 0033-4545 (ISSN-L)
- 1365-3075
- OpenAlex
- W2162335334
- Cited by
- 909
- References
- 5
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.