Effects of Loading Frequency on Mechanically Induced Bone Formation
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The anabolic effect of mechanical loading on bone tissue is modulated by loading frequency. The objective of this study was to characterize the new bone formation on the periosteal and endocortical surfaces of the ulnar diaphysis in adult, female rats in response to controlled dynamic loading and to examine the interactions between strain magnitude, loading frequency, and bone formation rate (BFR/BS) for frequencies ranging from 1 to 10 Hz. Cyclic, compressive loading was applied to the ulnas of 60 adult, female rats divided into 12 loading groups. Loading was applied for 360 cycles/day with peak loads ranging from 4.3 to 18N at frequencies of 1, 5, and 10 Hz. After 2 weeks of loading, bone formation on the periosteal and endocortical surfaces of the ulna was quantified using double-label histomorphometry on transverse sections obtained at the middiaphysis. Periosteal bone formation increased in a dose-response manner with peak load at each of the three loading frequencies tested. Loading frequency significantly affected the x intercepts and slopes of the peak strain versus BFR/BS (p < 0.001) and peak strain versus mineralizing surface (MS/BS; p < 0.001) curves. Periosteal osteogenesis was best predicted by a mathematical model that assumed: (1) bone cells are activated by fluid shear stresses and (2) that stiffness of the bone cells and the extracellular matrix near the cells increases at higher loading frequencies because of viscoelasticity. Consequently, mechanotransduction appears to involve a complex interaction between extracellular fluid forces and cellular mechanics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baltosser, W. H., & Zar, J. H. (1996) · Ecology · doi:10.2307/2265725 · Cited by 35,166
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Regulation of bone mass by mechanical strain magnitude
Rubin, C. T., & Lanyon, L. E. (1985) · Calcified Tissue International · doi:10.1007/bf02553711 · Cited by 1,294
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Three rules for bone adaptation to mechanical stimuli
Turner, C. H. (1998) · Bone · doi:10.1016/s8756-3282(98)00118-5 · Cited by 969
Self-citationFung, Y. C. (1981) · Springer eBooks · doi:10.1007/978-1-4757-1752-5 · Cited by 580
Mechanical loading thresholds for lamellar and woven bone formation
Dr. Turner, C. H., Forwood, M. R., Rho, J.-Y., & Yoshikawa, T. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090113 · Cited by 475
Differential effect of steady versus oscillating flow on bone cells
Jacobs, C. R., Yellowley, C. E., Davis, B. R., Zhou, Z., Cimbala, J. M., & Donahue, H. J. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00114-6 · Cited by 453
Mechanotransduction in bone: do bone cells act as sensors of fluid flow?
Turner, C. H., Forwood, M. R., & Otter, M. W. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.11.8070637 · Cited by 411
Self-citationPavalko, F. M., Chen, N. X., Turner, C. H., Burr, D. B., Atkinson, S., Hsieh, Y.-F., Qiu, J., & Duncan, R. L. (1998) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1998.275.6.c1591 · Cited by 404
Self-citation
Cited by
BIOMECHANICAL AND MOLECULAR REGULATION OF BONE REMODELING
Robling, A. G., Castillo, A. B., & Turner, C. H. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095721 · Cited by 1,343
Self-citationThe aging of Wolff’s “law”: Ontogeny and responses to mechanical loading in cortical bone
Pearson, O. M., & Lieberman, D. E. (2004) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20155 · Cited by 745
“…it is important to keep in mind that the rate of loading (the rate at which stress is increased and then released) appears to be particularly crucial in eliciting a response from bone cells, and that high loading rates are more potent stimulators of new bone formation (Hsieh and Turner, 2001).”
BackgroundMechanical Strain and Bone Cell Function: A Review
Ehrlich, P. J., & Lanyon, L. E. (2002) · Osteoporosis International · doi:10.1007/s001980200095 · Cited by 512
Designing Exercise Regimens to Increase Bone Strength
Turner, C. H., & Robling, A. G. (2003) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200301000-00009 · Cited by 499
Self-citationEffects of biomechanical stress on bones in animals
Burr, D. B., Robling, A. G., & Turner, C. H. (2002) · Bone · doi:10.1016/s8756-3282(02)00707-x · Cited by 466
Self-citationMatthews, B. D., Overby, D. R., Mannix, R., & Ingber, D. E. (2006) · Journal of Cell Science · doi:10.1242/jcs.02760 · Cited by 455
Mechanical Signaling for Bone Modeling and Remodeling
Robling, A. G., & Turner, C. H. (2009) · Critical Reviews™ in Eukaryotic Gene Expression · doi:10.1615/critreveukargeneexpr.v19.i4.50 · Cited by 422
Self-citationBorer, K. T. (2005) · Sports Medicine · doi:10.2165/00007256-200535090-00004 · Cited by 373
Effects of Resistance Exercise on Bone Health
Hong, A. R., & Kim, S. W. (2018) · Endocrinology and Metabolism · doi:10.3803/enm.2018.33.4.435 · Cited by 291
Hsieh, Y.-F., Robling, A. G., Ambrosius, W. T., Burr, D. B., & Turner, C. H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.12.2291 · Cited by 268
Self-citationBone and metal: An orthopaedic perspective on osseointegration of metals
Goriainov, V., Cook, R., M. Latham, J., G. Dunlop, D., & Oreffo, R. O. C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.004 · Cited by 223
Exercise When Young Provides Lifelong Benefits to Bone Structure and Strength
Warden, S. J., Fuchs, R. K., Castillo, A. B., Nelson, I. R., & Turner, C. H. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061107 · Cited by 190
“Distal bone sections taken from ulna pairs that were strength tested (N 10 pairs) were embedded in methylmethacrylate, as previously described.((16,17)) Transverse bone sections were taken at”
BackgroundMethodSelf-citationArnoczky, S. P., Tian, T., Lavagnino, M., & Gardner, K. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00185-2 · Cited by 177
“As in bone [21], the effect of loading history on cytoskeletal adaptations and matrix interactions could provide a key to understanding the effect of various mechanical loading regimes on tendon health.”
Lavagnino, M., Arnoczky, S. P., Tian, T., & Vaupel, Z. (2003) · Connective Tissue Research · doi:10.1080/03008200390215881 · Cited by 175
Distinct Anabolic Response of Osteoblast to Low-Intensity Pulsed Ultrasound
Naruse, K., Miyauchi, A., Itoman, M., & Mikuni-Takagaki, Y. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.2.360 · Cited by 173
“Lower intensity, however, is compensated by the strain frequency((13,14)) or by the strain rate when the frequency is relatively low.”
BackgroundZuo, B., Zhu, J., Li, J., Wang, C., Zhao, X., Cai, G., Li, Z., Peng, J., Wang, P., Shen, C., et al. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2352 · Cited by 173
Lee, K. C. L., Maxwell, A., & Lanyon, L. E. (2002) · Bone · doi:10.1016/s8756-3282(02)00842-6 · Cited by 169
Mechanisms by which exercise improves bone strength
Turner, C. H., & Robling, A. G. (2005) · Journal of Bone and Mineral Metabolism · doi:10.1007/bf03026318 · Cited by 159
“formation when applied at 10 cycles/s (Hz), compared to application at 1 Hz [12].”
MethodSelf-citationBarbe, M. F., Gallagher, S., Massicotte, V. S., Tytell, M., Popoff, S. N., & Barr-Gillespie, A. E. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-303 · Cited by 135
“[52,109,115], especially if animals are allowed a rest”
BackgroundResultInfluentialAlghadir, A. H., Gabr, S. A., & Al-Eisa, E. (2015) · Journal of Physical Therapy Science · doi:10.1589/jpts.27.2261 · Cited by 75
Beller, G., Belavý, D. L., Sun, L., Armbrecht, G., Alexandre, C., & Felsenberg, D. (2011) · Bone · doi:10.1016/j.bone.2011.06.021 · Cited by 60
Bou Assaf, R., Fayyad-Kazan, M., Al-Nemer, F., Makki, R., Fayyad-Kazan, H., Badran, B., & Berbéri, A. (2019) · BioMed Research International · doi:10.1155/2019/2868673 · Cited by 25
Metadata
- Authors
- Hsieh, Y.-F., & Turner, C. H.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-05-01
- Volume
- 16
- Issue
- 5
- Pages
- 918-924
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2027237953
- Cited by
- 370
- References
- 27
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.