Broadband absorption spectroscopy in turbid media by combined frequency-domain and steady-state methods
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A technique for measuring broadband near-infrared absorption spectra of turbid media that uses a combination of frequency-domain (FD) and steady-state (SS) reflectance methods is presented. Most of the wavelength coverage is provided by a white-light SS measurement, whereas the FD data are acquired at a few selected wavelengths. Coefficients of absorption (mu(a)) and reduced scattering (mu(s)') derived from the FD data are used to calibrate the intensity of the SS measurements and to estimate mu(s)' at all wavelengths in the spectral window of interest. After these steps are performed, one can determine mu(a) by comparing the SS reflectance values with the predictions of diffusion theory, wavelength by wavelength. Absorption spectra of a turbid phantom and of human breast tissue in vivo, derived with the combined SSFD technique, agree well with expected reference values. All measurements can be performed at a single source-detector separation distance, reducing the variations in sampling volume that exist in multidistance methods. The technique uses relatively inexpensive light sources and detectors and is easily implemented on an existing multiwavelength FD system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Self-citationWray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Refractive indices of water and ice in the 065- to 25-μm spectral range
Kou, L., Labrie, D., & Chylek, P. (1993) · Applied Optics · doi:10.1364/ao.32.003531 · Cited by 800
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Self-citation
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Self-citationMa, Y., Shaik, M. A., Kim, S. H., Kozberg, M. G., Thibodeaux, D. N., Zhao, H. T., Yu, H., & Hillman, E. M. C. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2015.0360 · Cited by 335
Assessing the future of diffuse optical imaging technologies for breast cancer management
Tromberg, B. J., Pogue, B. W., Paulsen, K. D., Yodh, A. G., Boas, D. A., & Cerussi, A. E. (2008) · Medical Physics · doi:10.1118/1.2919078 · Cited by 326
Self-citationChoe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Self-citationNew frontiers in time-domain diffuse optics, a review
Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091310 · Cited by 245
“The wavelength multiplexing, in this case, relies on the detection stage using dispersive elements like diffraction gratings.(19,77,78) It is worth noting that, by using this scheme, the injected power is fixed for the broadband light source; thus, due to spectral response of the tissue, the detected signal can strong…”
MethodReview of Electromagnetic Techniques for Breast Cancer Detection
Hassan, A. M., & El-Shenawee, M. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2169780 · Cited by 214
Spectroscopy enhances the information content of optical mammography
Cerussi, A. E., Jakubowski, D., Shah, N., Bevilacqua, F., Lanning, R., Berger, A. J., Hsiang, D., Butler, J., Holcombe, R. F., & Tromberg, B. J. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1427050 · Cited by 172
Self-citationBale, G., Elwell, C. E., & Tachtsidis, I. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091307 · Cited by 169
“In 2000, a combined CW and FD NIRS system was developed to use measurements of μ 0 s and the absorption coefficient (μa) to inform the calculation of absolute chromophore concentrations.(109) This was further developed by UCL to the”
Three-dimensional surface profile intensity correction for spatially modulated imaging
Gioux, S., Mazhar, A., Cuccia, D. J., Durkin, A. J., Tromberg, B. J., & Frangioni, J. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3156840 · Cited by 161
“Spectral absorption and reduced scattering coefficients of the calibration phantom were verified using a two-distance, multifrequency, frequency-domain photon migration (FDPM) measurement, which is a selfcalibrating measurement (26).”
MethodSelf-citationIn vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy
Tseng, S.-H., Grant, A., & Durkin, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2829772 · Cited by 139
In Vivo Measurement of Optical Properties of Human Skin for 450–800 nm and 950–1600 nm Wavelengths
Kono, T., & Yamada, J. (2019) · International Journal of Thermophysics · doi:10.1007/s10765-019-2515-3 · Cited by 62
Phan, T., Rowland, R., Ponticorvo, A., Le, B. C., Wilson, R. H., Sharif, S. A., Kennedy, G. T., Bernal, N. P., & Durkin, A. J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.2.026001 · Cited by 38
“19,31,33,34 However, our measured μ 0 s from darker skin (Fitzpatrick skin types III to VI) tended to increase with wave-length for almost all anatomical locations except the palm.”
Background
Metadata
- Authors
- Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2000-12-01
- Volume
- 39
- Issue
- 34
- Pages
- 6498
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W4214931116
- Cited by
- 284
- References
- 29
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.